Peugeot 2008

Parameters

The Peugeot 2008 has 576 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

High voltage battery charge, calibrated 2008_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID D410
  • Module6B4 → 694
  • Every1 s
  • Testing for 2013 to 2020, 2023 to 2026

Example reply from a 2022 Peugeot 2008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

0x65D9 = 26073 → 26073512 = 50.923828 %

Confirmed for 2021 to 2022. In testing for 2013 to 2014, 2016, 2019, 2025 to 2026. Not supported for 2015, 2017 to 2018, 2020, 2023 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal signal 1 voltage 2008_ACCEL_PEDAL_SIG_1_V

  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2013 to 2026.

Accelerator pedal signal 2 voltage 2008_ACCEL_PEDAL_SIG_2_V

  • Service 22DID D406
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2013 to 2026.

Approximate position of turbocharger actuator 2008_APPROXIMATE_POS

  • Service 22DID D4EC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2013 to 2026.

Average cell voltage value 2008_AVG_CELL_V

  • Service 22DID D43D
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery average temperature 2008_BAT_AVG_T

  • Service 22DID D877
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Battery cell 001 voltage 2008_BAT_CELL_001_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 002 voltage 2008_BAT_CELL_002_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 003 voltage 2008_BAT_CELL_003_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 004 voltage 2008_BAT_CELL_004_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 005 voltage 2008_BAT_CELL_005_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 006 voltage 2008_BAT_CELL_006_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 007 voltage 2008_BAT_CELL_007_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 008 voltage 2008_BAT_CELL_008_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 009 voltage 2008_BAT_CELL_009_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 010 voltage 2008_BAT_CELL_010_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 011 voltage 2008_BAT_CELL_011_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 012 voltage 2008_BAT_CELL_012_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 013 voltage 2008_BAT_CELL_013_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 014 voltage 2008_BAT_CELL_014_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 015 voltage 2008_BAT_CELL_015_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 016 voltage 2008_BAT_CELL_016_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 017 voltage 2008_BAT_CELL_017_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 018 voltage 2008_BAT_CELL_018_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 019 voltage 2008_BAT_CELL_019_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 020 voltage 2008_BAT_CELL_020_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 021 voltage 2008_BAT_CELL_021_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 022 voltage 2008_BAT_CELL_022_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 023 voltage 2008_BAT_CELL_023_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 024 voltage 2008_BAT_CELL_024_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 025 voltage 2008_BAT_CELL_025_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 026 voltage 2008_BAT_CELL_026_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 027 voltage 2008_BAT_CELL_027_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 028 voltage 2008_BAT_CELL_028_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 029 voltage 2008_BAT_CELL_029_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 030 voltage 2008_BAT_CELL_030_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 031 voltage 2008_BAT_CELL_031_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 032 voltage 2008_BAT_CELL_032_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 033 voltage 2008_BAT_CELL_033_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 034 voltage 2008_BAT_CELL_034_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 035 voltage 2008_BAT_CELL_035_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 036 voltage 2008_BAT_CELL_036_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 037 voltage 2008_BAT_CELL_037_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 038 voltage 2008_BAT_CELL_038_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 039 voltage 2008_BAT_CELL_039_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 040 voltage 2008_BAT_CELL_040_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 041 voltage 2008_BAT_CELL_041_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 042 voltage 2008_BAT_CELL_042_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 043 voltage 2008_BAT_CELL_043_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 044 voltage 2008_BAT_CELL_044_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 045 voltage 2008_BAT_CELL_045_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 046 voltage 2008_BAT_CELL_046_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 047 voltage 2008_BAT_CELL_047_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 048 voltage 2008_BAT_CELL_048_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 049 voltage 2008_BAT_CELL_049_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 050 voltage 2008_BAT_CELL_050_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 051 voltage 2008_BAT_CELL_051_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 052 voltage 2008_BAT_CELL_052_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 053 voltage 2008_BAT_CELL_053_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 054 voltage 2008_BAT_CELL_054_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 055 voltage 2008_BAT_CELL_055_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 056 voltage 2008_BAT_CELL_056_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 057 voltage 2008_BAT_CELL_057_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 058 voltage 2008_BAT_CELL_058_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 059 voltage 2008_BAT_CELL_059_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 060 voltage 2008_BAT_CELL_060_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 061 voltage 2008_BAT_CELL_061_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 062 voltage 2008_BAT_CELL_062_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 063 voltage 2008_BAT_CELL_063_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 064 voltage 2008_BAT_CELL_064_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 065 voltage 2008_BAT_CELL_065_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 066 voltage 2008_BAT_CELL_066_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 067 voltage 2008_BAT_CELL_067_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 068 voltage 2008_BAT_CELL_068_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 069 voltage 2008_BAT_CELL_069_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 070 voltage 2008_BAT_CELL_070_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 071 voltage 2008_BAT_CELL_071_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 072 voltage 2008_BAT_CELL_072_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 073 voltage 2008_BAT_CELL_073_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 074 voltage 2008_BAT_CELL_074_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 075 voltage 2008_BAT_CELL_075_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 076 voltage 2008_BAT_CELL_076_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 077 voltage 2008_BAT_CELL_077_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 078 voltage 2008_BAT_CELL_078_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 079 voltage 2008_BAT_CELL_079_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 080 voltage 2008_BAT_CELL_080_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 081 voltage 2008_BAT_CELL_081_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 082 voltage 2008_BAT_CELL_082_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 083 voltage 2008_BAT_CELL_083_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 084 voltage 2008_BAT_CELL_084_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 085 voltage 2008_BAT_CELL_085_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 086 voltage 2008_BAT_CELL_086_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 087 voltage 2008_BAT_CELL_087_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 088 voltage 2008_BAT_CELL_088_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 089 voltage 2008_BAT_CELL_089_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 090 voltage 2008_BAT_CELL_090_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 091 voltage 2008_BAT_CELL_091_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 092 voltage 2008_BAT_CELL_092_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 093 voltage 2008_BAT_CELL_093_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 094 voltage 2008_BAT_CELL_094_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 095 voltage 2008_BAT_CELL_095_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 096 voltage 2008_BAT_CELL_096_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 097 voltage 2008_BAT_CELL_097_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 098 voltage 2008_BAT_CELL_098_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 099 voltage 2008_BAT_CELL_099_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,568 to 1,583 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 100 voltage 2008_BAT_CELL_100_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,584 to 1,599 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 101 voltage 2008_BAT_CELL_101_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,600 to 1,615 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 102 voltage 2008_BAT_CELL_102_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,616 to 1,631 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 103 voltage 2008_BAT_CELL_103_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,632 to 1,647 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 104 voltage 2008_BAT_CELL_104_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,648 to 1,663 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 105 voltage 2008_BAT_CELL_105_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,664 to 1,679 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 106 voltage 2008_BAT_CELL_106_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,680 to 1,695 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 107 voltage 2008_BAT_CELL_107_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,696 to 1,711 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 108 voltage 2008_BAT_CELL_108_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,712 to 1,727 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 109 voltage 2008_BAT_CELL_109_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,728 to 1,743 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 110 voltage 2008_BAT_CELL_110_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,744 to 1,759 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 111 voltage 2008_BAT_CELL_111_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,760 to 1,775 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 112 voltage 2008_BAT_CELL_112_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,776 to 1,791 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 113 voltage 2008_BAT_CELL_113_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,792 to 1,807 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 114 voltage 2008_BAT_CELL_114_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,808 to 1,823 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 115 voltage 2008_BAT_CELL_115_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,824 to 1,839 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 116 voltage 2008_BAT_CELL_116_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,840 to 1,855 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 117 voltage 2008_BAT_CELL_117_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,856 to 1,871 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 118 voltage 2008_BAT_CELL_118_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,872 to 1,887 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 119 voltage 2008_BAT_CELL_119_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,888 to 1,903 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery cell 120 voltage 2008_BAT_CELL_120_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,904 to 1,919 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Battery current 2008_BAT_CURRENT

  • Service 22DID D497
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1024
Range
-2097152 to 2097151 A
Unit
A

In testing for 2013 to 2026.

Battery DC current 2008_BAT_DC_CURRENT

  • Service 22DID D816
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val64−1200
Range
-1200 to 67107663 A
Unit
A

In testing for 2013 to 2026.

Battery insulation resistance 2008_BAT_INSULATION_RES

  • Service 22DID D47A
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kΩ
Unit
kΩ

In testing for 2013 to 2026.

Battery max unit temperature 2008_BAT_MAX_UNIT_T

  • Service 22DID D817
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Battery max unit temperature number 2008_BAT_MAX_UNIT_T_NUMBER

  • Service 22DID D445
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2013 to 2026.

Battery min unit temperature 2008_BAT_MIN_UNIT_T

  • Service 22DID D87D
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Battery min unit temperature number 2008_BAT_MIN_UNIT_T_NUMBER

  • Service 22DID D446
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2013 to 2026.

Battery temperature 2008_BAT_T

  • Service 22DID D8EF
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2013 to 2026.

Cell voltage sum 2008_CELL_V_SUMM

  • Service 22DID D438
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2013 to 2026.

Centralized voltage maintenance device temperature limiter state 2008_CENTRALIZED_V_T

  • Service 22DID D759
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Computer power supply voltage 2008_COMPUTER_POWER_SUP_V

  • Service 22DID D551
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2013 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2017 to 2018, 2020. Supported for 2015 to 2016, 2021, 2023 to 2024.

Energy accumulator discharge permission state 2008_ENERGY_ACCUMULATOR

  • Service 22DID D74F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine control computer supply voltage 2008_ENG_CTRL_COMPUTER_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 V
Unit
V

In testing for 2013 to 2026.

Engine oil level sensor voltage 2008_ENG_OIL_LEVEL_SENS_V

  • Service 22DID D41E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2013 to 2026.

Evaluation of the total resistance of the voltage maintaining device 2008_EVALUATION_TOT_RES_V

  • Service 22DID D72D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128040.9703
Range
0 to 0.511
Unit
Number

In testing for 2013 to 2026.

High voltage battery charge 2008_HVBAT_SOC_RAW

Pelican can show this parameter as the state of charge.

  • Service 22DID D810
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

High voltage battery charge, calibrated 2008_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID D410
  • Module6B4 → 694
  • Every1 s
  • Testing for 2013 to 2020, 2023 to 2026

Example reply from a 2022 Peugeot 2008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

0x65D9 = 26073 → 26073512 = 50.923828 %

Confirmed for 2021 to 2022. In testing for 2013 to 2014, 2016, 2019, 2025 to 2026. Not supported for 2015, 2017 to 2018, 2020, 2023 to 2024.

High voltage battery health 2008_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID D860
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val16
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

High voltage battery voltage 2008_HVBAT_VOLT

  • Service 22DID D815
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2013 to 2026.

High voltage maximum voltage 2008_HVBAT_MAX_VOLT

  • Service 22DID D870
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2013 to 2026.

High voltage minimum voltage 2008_HVBAT_MIN_VOLT

  • Service 22DID D86F
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2013 to 2026.

Highest voltage cell number 2008_HIGHEST_V_CELL

  • Service 22DID D43B
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2013 to 2026.

HV battery energy 2008_HVBAT_KWH

Energy stored in the high voltage battery

  • Service 22DID D865
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 kWh
Unit
kWh

In testing for 2013 to 2026.

Lowest voltage cell number 2008_LOWEST_V_CELL_NUMBER

  • Service 22DID D43C
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2013 to 2026.

Maximum power the battery can provide for 10 seconds 2008_MAX_POWER_BAT_CAN_PROVIDE_10

  • Service 22DID D873
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2013 to 2026.

Maximum power the battery can provide for 30 seconds 2008_MAX_POWER_BAT_CAN_PROVIDE_30

  • Service 22DID D874
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2013 to 2026.

Maximum power the battery can withstand for 10 seconds 2008_MAX_POWER_BAT_CAN_10

  • Service 22DID D871
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2013 to 2026.

Maximum power the battery can withstand for 30 seconds 2008_MAX_POWER_BAT_CAN_30

  • Service 22DID D872
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2013 to 2026.

Minimum battery voltage at startup 2008_MIN_BAT_V_STARTUP

  • Service 22DID D4D4
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50.00000112
Range
-655 to 655 V
Unit
V

In testing for 2013 to 2026.

On-board charger temperature 2008_ON_BOARD_CHARGER_T

  • Service 22DID D8E1
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Reversible generator voltage 2008_REVERSIBLE_GEN_V

  • Service 22DID D713
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2013 to 2026.

Service battery charge state 2008_SERVICE_BAT_CHG_ST

  • Service 22DID D742
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Service battery charge status 2008_SERVICE_BAT_CHG_STAT

  • Service 22DID D467
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2013 to 2026.

Service battery temperature 2008_SERVICE_BAT_T

  • Service 22DID D496
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Service battery temperature 2008_SERVICE_BAT_T_6A8

  • Service 22DID D496
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2013 to 2026.

Service battery voltage 2008_SERVICE_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D78A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2013 to 2026.

Service battery wear condition 2008_SERVICE_BAT_WEAR

  • Service 22DID D741
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Service cell voltage value 2008_SERVICE_CELL_V

  • Service 22DID D822
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2013 to 2026.

Set voltage of energy storage 2008_SET_V_ENERGY_STORAGE

  • Service 22DID D734
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2013 to 2026.

Set voltage of storage battery charging 2008_SET_V_STORAGE_BAT

  • Service 22DID D766
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2013 to 2026.

Set voltage of the reversible generator 2008_SET_V_REVERSIBLE_GEN

  • Service 22DID D712
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val39.9999994+10.60000038
Range
0 to 16.97 V
Unit
V

In testing for 2013 to 2026.

Stop permitted by voltage maintainer computer 2008_STOP_PERMITTED_V

  • Service 22DID D749
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Temperature of the electronic power unit of the voltage maintenance device 2008_T_ELECTRONIC_POWER_V

  • Service 22DID D730
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2013 to 2026.

Turbocharger control duty cycle 2008_TURBOCHARGER_CTRL

  • Service 22DID D48A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 127 %
Unit
%

In testing for 2013 to 2026.

Turbocharger first electronic boost 2008_TURBOCHARGER_FIRST

  • Service 22DID D48C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Turbocharger position information 2008_TURBOCHARGER_POS

  • Service 22DID D4EA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 %
Unit
%

In testing for 2013 to 2026.

Turbocharger pressure measured 2008_TURBOCHARGER_P_MEAS

  • Service 22DID D4D9
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2013 to 2026.

Turbocharger pressure reference 2008_TURBOCHARGER_P

  • Service 22DID D556
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2013 to 2026.

Turbocharger, target position 2008_TURBOCHARGER_TGT_POS

  • Service 22DID D47B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Voltage at the terminals of the energy accumulator 2008_V_TERMINALS_ENERGY

  • Service 22DID D720
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2013 to 2026.

Voltage maintainer computer request sent 2008_V_MAINTAINER_COMPUTER_REQ

  • Service 22DID D748
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Voltage maintainer computer restart permission 2008_V_MAINTAINER

  • Service 22DID D747
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Voltage maintainer status 2008_V_MAINTAINER_STAT

  • Service 22DID D72C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2015, 2017 to 2018. Supported for 2020 to 2021, 2023 to 2024.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2015 to 2018, 2021, 2023 to 2024.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2015 to 2018, 2021, 2024.

Anti-lock brake or stability control regulating 2008_ABS_EKS_PROCESS_ADJ

  • Service 22DID D474
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Brake circuit pressure 2008_BRAKE_CIRCUIT_P

  • Service 22DID D70E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498 bar
Unit
bar

In testing for 2013 to 2026.

Brake system backup contactor status 2008_BRAKE_SYSTEM_BACKUP

  • Service 22DID D463
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Main brake contactor status 2008_MAIN_BRAKE_CONTACTOR

  • Service 22DID D513
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Secondary brake contactor status 2008_SECONDARY_BRAKE

  • Service 22DID D514
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Vacuum present in the brake system 2008_VACUUM_PRESENT_BRAKE

  • Service 22DID D700
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2015, 2017 to 2018, 2020, 2024. Supported for 2021, 2023.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2018. Supported for 2023.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2018. Supported for 2016, 2021, 2023.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.

Engine

5V power supply state number 1 2008_5V_POWER_SUP_ST_1

  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

5V power supply state number 2 2008_5V_POWER_SUP_ST_2

  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

5V power supply state number 3 2008_5V_POWER_SUP_ST_3

  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

5V power supply state number 4 2008_5V_POWER_SUP_ST_4

  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

12V network allowed stop 2008_12V_NETWORK_ALLOWED

  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Activation count, brake electromagnetic valve B1 2008_NUM_ACTIVATIONS_B1

  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, line pressure control solenoid 2008_NUM_LINE_P_CTRL

  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, the electromagnetic valve of brake B2 2008_NUM_ACTIVATIONS_B2

  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Actual oil pressure 2008_ACT_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 bar
Unit
bar

In testing for 2013 to 2026.

Additional heater control 1 2008_ADDITIONAL_HEATER_1

  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Air conditioning 2008_AC

  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Air conditioning compressor current 2008_AC_COMP_CURRENT

  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375
Unit
Number

In testing for 2013 to 2026.

Air conditioning high side pressure 2008_AC_HIGH_SIDE_P

  • Service 22DID D8FF
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2013 to 2026.

Air conditioning pressure 2008_AC_P

  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2013 to 2026.

Air doser first electronic loading 2008_AIR_DOSER_FIRST

  • Service 22DID D53B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Air flow 2008_AIR_FLOW

  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2013 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2023.

Air flow target 2008_AIR_FLOW_TGT

  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2013 to 2026.

Air metering valve duty cycle 2008_AIR_METERING_VLV

  • Service 22DID D461
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Air metering valve position 2008_AIR_METERING_VLV_POS

  • Service 22DID D54F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Air metering valve, target position 2008_AIR_METERING_VLV_TGT

  • Service 22DID D460
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Air temperature by air flow meter 2008_AIR_T_AIR_FLOW_METER

  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2013 to 2026.

Alternator load value 2008_ALTERNATOR_LOAD

  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Ambient air temperature 2008_AAT_6A9

  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2013 to 2026.

Ambient temperature 2008_AAT

  • Service 22DID D434
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2013 to 2026.

ANTI START PROGRAMMING STATUS 2008_ANTI_START

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Atmospheric pressure 2008_ATMOSPHERIC_P

  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2013 to 2026.

Automatic restart request from body control module 2008_AUTOMATIC_RESTART_REQ_BSI

  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic restart request from engine management computer 2008_AUTOMATIC_RESTART

  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic stop allowed by body control module 2008_AUTOMATIC_STOP

  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic stop allowed by power steering computer 2008_AUTOMATIC_STOP_ALLOWED_POWER_STEER

  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Auxiliary heater 2 control 2008_AUXILIARY_HEATER_2

  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Average mileage for the last 10 regenerations 2008_AVG_MILEAGE_LAST_10

  • Service 22DID D525
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val16
Range
0 to 4095 km
Unit
km

In testing for 2013 to 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.

Boost air temperature 2008_BOOST_AIR_T

  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2013 to 2026.

Button state 2008_BUTTON_ST

  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023 to 2024. Supported for 2016.

Camshaft/crankshaft position synchronization 2008_CAM_CRANK_POS

  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2017 to 2018. Supported for 2015, 2020 to 2021, 2023 to 2024.

CHANGE REPORT IN PROGRESS 2008_CHANGE_REPORT

  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Combustion engine state 2008_ICE_ST

  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2015, 2017 to 2018, 2020, 2024. Supported for 2021.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2024.

Commanded oil pressure 2008_CMD_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2013 to 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018. Supported for 2015, 2021, 2023 to 2024.

Commanded wastegate A position WG_A_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Commanded wastegate B position WG_B_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Computer lock 2008_COMPUTER_LOCK

  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Computer remote wake-up state 2008_COMPUTER_WAKE_UP_ST

  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Computer restarts since memory erase 2008_CNT_NUM_RE

  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Computer temperature 2008_COMPUTER_T

  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Control current of electromagnetic valve for changing the pressure in the brake system B2 2008_CTRL_CURRENT_P_B2

  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 2008_CTRL_CURRENT_P_B1

  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Controlled air supply module 2008_CONTROLLED_AIR_SUP

  • Service 22DID D4A0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Coolant temperature 2008_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D8FB
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2013 to 2026.

Coolant temperature 2008_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2013 to 2026.

Coolant temperature target 2008_ECT_TGT

  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Coolant temperature, corrected 2008_ECT_CORRECTED

  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Cruise control, RW status 2008_CRUISE_CTRL_RW_STAT

  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Cylinder 1 injector flow correction 2008_CYL_1_INJ_FLOW_CORR

  • Service 22DID D546
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2026.

Cylinder 2 injector flow correction 2008_CYL_2_INJ_FLOW_CORR

  • Service 22DID D547
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2026.

Cylinder 3 injector flow correction 2008_CYL_3_INJ_FLOW_CORR

  • Service 22DID D548
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2026.

Cylinder 4 injector flow correction 2008_CYL_4_INJ_FLOW_CORR

  • Service 22DID D549
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2026.

Date 2008_DATE

  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

In testing for 2013 to 2026.

Drive motor coolant inlet temperature 2008_DRIVE_MOTOR_CLT_T

  • Service 22DID D8D6
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Drive motor power 2008_DRIVE_MOTOR_POWER

  • Service 22DID D8D9
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 W
Unit
W

In testing for 2013 to 2026.

Drive motor stator temperature 2008_DRIVE_MOTOR_STATOR_T

  • Service 22DID D8CD
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Drive motor torque, actual 2008_DRIVE_MOTOR_TQ_ACT

  • Service 22DID D8D0
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2013 to 2026.

Drive motor torque, desired 2008_DRIVE_MOTOR_TQ_DES

  • Service 22DID D880
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 N·m
Unit
N·m

In testing for 2013 to 2026.

Driver presence 2008_DRIVER_PRESENCE

  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Driver, requested torque value 2008_DRIVER_REQ_TQ

  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2013 to 2026.

Economy mode off state 2008_ECO_MODE_OFF_ST

  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Electric cooling fan control 2008_GMV_ELEC_COOLING_FAN

  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Electric machine torque 2008_ELEC_MACHINE_TQ

  • Service 22DID DCB6
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−1638.3
Range
-1638 to 4915 N·m
Unit
N·m

In testing for 2013 to 2026.

Electric machine torque reduction 2008_ELEC_MACHINE_TQ_REDUCTION

  • Service 22DID DC69
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2013 to 2026.

Energy accumulator state transfer 2008_ENERGY_ACCUMULATOR_ST

  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Energy accumulator temperature limiter state 2008_ENERGY_ACCUMULATOR_T

  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine control module status 2008_ENG_CTRL_MODULE_STAT

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine coolant temperature 2008_ECT_6A9

  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023 to 2024. Supported for 2016.

Engine oil dilution protection status 2008_ENG_OIL_DILUTION

  • Service 22DID D524
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine operating mode 2008_ENG_OP_MODE

  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2013 to 2026.

Engine restart counter 2008_ENG_RESTART_CNT

  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Engine restart counter by stop and start function 2008_ENG_RESTART_CNT_STOP

  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Engine restart request sent by ESP computer 2008_ENG_RESTART_REQ_SENT

  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.

Engine stalls 2008_ENG_STALLS

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine start prohibition control, start lock 2008_ENG_START

  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine stop time 2008_ENG_STOP_TIME

  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2013 to 2026.

Engine torque 2008_ENG_TQ

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2013 to 2026.

Estimated torque of internal friction of the engine 2008_ESTIMATED_TQ

  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

In testing for 2013 to 2026.

Evaluation of carbon content in engine oil 2008_EVALUATION_CARBON

  • Service 22DID D523
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 %
Unit
%

In testing for 2013 to 2026.

Evaluation of the degree of dilution of motor oil 2008_EVALUATION_DEGREE

  • Service 22DID D51F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2013 to 2026.

Exhaust gas recirculation high limit electronic loading 2008_EGR_HIGH_LIM

  • Service 22DID D553
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Exhaust gas recirculation low limit electronic loading 2008_EGR_LOW_LIM

  • Service 22DID D552
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Exhaust gas recirculation valve duty cycle 2008_EGR_VLV_CTRL_SIG_RCO

  • Service 22DID D511
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Exhaust gas recirculation valve first electronic loading 2008_EGR_VLV_FIRST

  • Service 22DID D53A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Exhaust gas recirculation valve position 2008_EGR_VLV_POS

  • Service 22DID D509
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Exhaust gas recirculation valve set position 2008_EGR_VLV_SET_POS

  • Service 22DID D510
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Expected generator supplier identifier of the reversible generator 2008_EXPECTED_GEN

  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Expected identifier of electronic power circuit of reversible generator generator 2008_EXPECTED_IDENTIFIER_ELECTRONIC

  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Expected identifier of reversible generator 2008_EXPECTED_IDENTIFIER

  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2017 to 2018. Supported for 2015, 2020 to 2021, 2023 to 2024.

FUGITIVE TRIP IN EMERGENCY MODE 2008_FUGITIVE_TRIP

  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Generator mode 2008_GEN_MODE

  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×75
Range
0 to 19125 rpm
Unit
rpm

In testing for 2013 to 2026.

Generator shutdown 2008_GEN_SHUTDOWN

  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Identifier of the electronic power circuit of the reversible generator 2008_IDENTIFIER

  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Identifier of the supplier of the reversible generator 2008_IDENTIFIER_SUPPLIER

  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Immobilizer code programming status 2008_IMMOBILIZER_CODE

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Indicated engine torque 2008_INDICATED_ENG_TQ

  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

In testing for 2013 to 2026.

Injector code 1 2008_INJ_CODE_1

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 47 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2013 to 2026.

Injector code 2 2008_INJ_CODE_2

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 72 to 111 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2013 to 2026.

Injector code 3 2008_INJ_CODE_3

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 136 to 175 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2013 to 2026.

Injector code 4 2008_INJ_CODE_4

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 200 to 239 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2013 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.

Inverter temperature estimated 2008_INVERTER_T_ESTIMATED

  • Service 22DID DC6A
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2013 to 2026.

Inverter temperature, commanded 2008_INVERTER_T_CMD

  • Service 22DID DC04
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2013 to 2026.

Line pressure solenoid valve control current 2008_SLT_LINE_P_VARIATION

  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Lock status 2008_LOCK_STAT

  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2024.

Long-term regeneration capability 2008_LONG_TERM_REGEN

  • Service 22DID D54D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Maximum allowable torque 2008_MAX_ALLOWABLE_TQ

  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2013 to 2026.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 2008_MEAS_CURRENT_P_B2

  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 2008_MEAS_CURRENT_P_B1

  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured line pressure variation solenoid valve current 2008_MEAS_LINE_P

  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Mileage since last oil change 2008_MILEAGE_SINCE_OIL

  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2026.

Minimum cell capacity 2008_MIN_CELL_CAP

  • Service 22DID D413
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2013 to 2026.

Movement of controlled air supply module 2008_MOVEMENT_CONTROLLED

  • Service 22DID D4EB
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Neutral position sensor status 2008_NEUTRAL_POS_SENS

  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Number of engine stop information deletion cycles 2008_NUM_ENG_STOP

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Oil pressure 2008_OIL_P

  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2013 to 2026.

Oil pressure reference value 2008_OIL_P_REFERENCE

  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2013 to 2026.

Oil pressure regulation control 2008_OIL_P_REGULATION

  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2013 to 2026.

Oil temperature 2008_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2013 to 2026.

Outside air temperature 2008_AAT_6A8

  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Powertrain condition 2008_POWERTRAIN_COND

  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Preheating relay control 2008_PREHEATING_RELAY

  • Service 22DID D50C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Presence of the identifier of the reversible generator 2008_PRESENCE_IDENTIFIER

  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Problems detected while transmitting unlock code 2008_PROBLEMS_DETECTED

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Problems detected while transmitting unlock code 2008_PROBLEMS_DETECTED_WHILE

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Real engine torque 2008_REAL_ENG_TQ

  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2013 to 2026.

Regeneration enable 2008_REGEN_ENABLE

  • Service 22DID D528
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Remote wake-up circuit status 2008_REMOTE_WAKE_UP

  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Remote wake-up state 2008_REMOTE_WAKE_UP_ST

  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Request to turn on the engine diagnostic indicator 2008_REQ_TURN_ON_ENG

  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Requested value controlled thermostat 2008_REQ_CONTROLLED

  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2013 to 2026.

Restart request sent by power steering computer 2008_RESTART_REQ_SENT

  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Restart request sent by suspension computer 2008_RESTART_REQ_SENT_SUSPENSION

  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Return to engine start and restart control by starter 2008_RETURN_ENG_START

  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Return to starter engine restart control 2008_RETURN_STARTER_ENG

  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Reverse generator status 2008_REVERSE_GEN_STAT

  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Reversible generator torque 2008_REVERSIBLE_GEN_TQ

  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2013 to 2026.

Service network related engine restart request 2008_SERVICE_NETWORK

  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2024. Supported for 2016.

Short-term regeneration capability 2008_SHORT_TERM_REGEN

  • Service 22DID D54C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Sport mode contactor state 2008_SPORT_MODE_CONTACTOR

  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Start inhibit control, wired 2008_START_INHIBIT_CTRL

  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Start or restart inhibition transmitted by engine management computer 2008_START_OR_RESTART

  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Start prohibition 2008_START_PROHIBITION

  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Starter activation counter 2008_STARTER_ACTIVATION

  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Starter control interface unit operating status 2008_STARTER_CTRL

  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Starter duty cycle 2008_STARTER_DUTY

  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2013 to 2026.

Starter engagement status 2008_STARTER_ENGAGEMENT

  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

State lock/unlock control unit 2008_ST_LOCK_UNLOCK_CTRL

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Status of internal ignition motor 2008_STAT_INTERNAL_IGN

  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Status of the energy accumulator 2008_STAT_ENERGY

  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Stop allowed by ESP computer 2008_STOP_ALLOWED_ESP

  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Stop and start function state 2008_STOP_START_FUNCTION

  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Stop and start switch 2008_STOP_START_SWITCH

  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Stop permitted by suspension computer 2008_STOP_PERMITTED

  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Temperature difference between the hottest and the coolest cells 2008_T_DIFF_HOTEST

  • Service 22DID D878
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2013 to 2026.

Temperature of the energy accumulator 2008_T_ENERGY_ACCUMULATOR

  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2013 to 2026.

The composition of the mixture is calculated by the oxygen sensor 2008_COMPOSITION_MIXTURE

  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2013 to 2026.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2024.

Torque corresponding to driver requirement 2008_TQ_CORRESPONDING

  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2013 to 2026.

Torque supplied or taken by generator 2008_TQ_SUPPLIED_OR_TAKEN

  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2013 to 2026.

Total mileage 2008_ODO_6A8

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2013 to 2026.

Towing device configured 2008_CAN_VEH_BE_EQUIPPED

  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Traction circuit coolant temperature 2008_TRACTION_CIRCUIT_ECT

  • Service 22DID D8F9
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2013 to 2026.

Traction or stability control regulating 2008_ASR_OR_ESP_SYSTEM

  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Transmission fluid temperature 2008_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2013 to 2026.

Vacuum circuit vacuum 2008_VACUUM_CIRCUIT

  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2013 to 2026.

Value during generator load smooth increase 2008_DURING_GEN_LOAD

  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Vehicle hour meter 2008_VEH_HOUR_METER

  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

In testing for 2013 to 2026.

Vehicle mileage since the last oil change under severe vehicle operating conditions 2008_VEH_MILEAGE_SINCE

  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2013 to 2026.

Wastegate A position WG_A_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Wastegate B position WG_B_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Winter mode switch state 2008_WINTER_MODE_SWITCH

  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Internal

Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018.

Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018.

Maximum value for air flow rate from mass air flow sensor MAX_MAFSAE J1979Confirmed

  • Service 01PID 50
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 g/s
Unit
g/s

Confirmed for 2018. Supported for 2023.

Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. Supported for 2023.

Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 kPa
Unit
kPa

Confirmed for 2018. Supported for 2023.

Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2018. Supported for 2023.

Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2018. Supported for 2023.

Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018.

Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2020, 2024.

O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed

  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2020, 2024.

Fuel

Amount of fuel additive remaining in the additive tank 2008_AMOUNT_FUEL_ADDITIVE

  • Service 22DID D56C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2013 to 2026.

Calculated fuel injection amount 2008_CALC_FUEL_INJ_AMOUNT

  • Service 22DID D563
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2013 to 2026.

Desired high pressure common rail fuel pressure 2008_DES_HIGH_P_COMMON_P

  • Service 22DID D445
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

In testing for 2013 to 2026.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2023 to 2024.

First fuel additive injection state 2008_FIRST_FUEL_ADDITIVE

  • Service 22DID D56F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Fuel pressure 2008_FUEL_P

  • Service 22DID D41F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val999.9999525
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2013 to 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2024.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2024.

Fuel temperature 2008_FUEL_T

  • Service 22DID D42A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2013 to 2026.

High fuel pressure measured 2008_HIGH_FUEL_P_MEAS

  • Service 22DID D446
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2013 to 2026.

Injection angle of the high-pressure fuel pump 2008_INJ_ANG_HIGH_P_FUEL

  • Service 22DID D588
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2013 to 2026.

Low pressure fuel pump actuator duty cycle 2008_LOW_P_FUEL_PMP

  • Service 22DID D472
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2013 to 2026.

Low pressure fuel pump status 2008_LOW_P_FUEL_PMP_STAT

  • Service 22DID D4ED
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Minimum fuel level 2008_MIN_FLI

  • Service 22DID D56A
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Movement

Accelerator pedal position 2008_ACCEL_PEDAL_POS

  • Service 22DID D407
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Accelerator pedal position 2008_ACCEL_PEDAL_POS_6A9

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×39100
Range
0 to 99.45 %
Unit
%

In testing for 2013 to 2026.

Accelerator pedal position 2008_ACCEL_PEDAL_POS_6A9_6A9

  • Service 22DID D505
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2013 to 2026.

Accelerator pedal position 2008_ACCEL_PEDAL_POS_6B4

  • Service 22DID D407
  • Module6B4 → 694
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Accelerator pedal position, recalculated 2008_ACCEL_PEDAL_POS_RECALCULATED

  • Service 22DID D407
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2013 to 2026.

Accelerator pedal position, track 1 2008_ACCEL_PEDAL_POS_1

  • Service 22DID D491
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2013 to 2026.

Accelerator pedal position, track 2 2008_ACCEL_PEDAL_POS_2

  • Service 22DID D492
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2013 to 2026.

Clutch release state at stop, creep speed reduction 2008_CLU_RELEASE_ST_STOP

  • Service 22DID D672
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Crankshaft speed 2008_CRANK_SPD

  • Service 22DID D462
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 rpm
Unit
rpm

In testing for 2013 to 2026.

Crankshaft speed determined by camshaft sensor 2008_CRANK_SPD_DETERMINED

  • Service 22DID D499
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2013 to 2026.

Cruise control set speed 2008_CRUISE_CTRL_SET_SPD

  • Service 22DID D475
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2026.

Engine RPM 2008_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID D400
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2013 to 2026.

Engine RPM 2008_RPM_6A9

Pelican can show this parameter as the engine speed.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2013 to 2026.

Input shaft speed 2008_INPUT_SHFT_SPD

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2013 to 2026.

Motor speed 2008_MOTOR_SPD

  • Service 22DID DC00
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2013 to 2026.

Set speed of electric cooling fan 2008_SET_SPD_ELEC_COOLING

  • Service 22DID D4AA
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

STATUS COMMANDS REGULATION OR LIMITATION SPEED 2008_STAT_COMMANDS

  • Service 22DID D704
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Torque converter slip speed, measured 2008_TQ_CONV_SLIP_SPD

  • Service 22DID D654
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2013 to 2026.

Vehicle speed 2008_VSS

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed 2008_VSS_6A8

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed 2008_VSS_6A9

Pelican can show this parameter as the speed.

  • Service 21PID C8
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed 2008_VSS_6A9_6A9

Pelican can show this parameter as the speed.

  • Service 22DID D711
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed 2008_VSS_6B4

Pelican can show this parameter as the speed.

  • Service 22DID D802
  • Module6B4 → 694
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×6465535
Range
0 to 4194368 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2024. Supported for 2016, 2023.

Vehicle speed limiter set speed 2008_VSS_LIMITER_SET_SPD

  • Service 22DID D476
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed limiter status, LW 2008_VSS_LIMITER_STAT_LW

  • Service 22DID D4C0
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Vehicle speed, ESP 2008_VSS_ESP

Pelican can show this parameter as the speed.

  • Service 22DID D802
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1953250000
Range
0 to 511 km/h
Unit
km/h

In testing for 2013 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.

Tires

Average front wheel speed 2008_AVG_FRONT_WHL_SPD

  • Service 22DID D530
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val25.00000056
Range
0 to 2621 rpm
Unit
rpm

In testing for 2013 to 2026.

Average speed front wheels 2008_AVG_SPD_FRONT_WHEELS

  • Service 22DID D533
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2013 to 2026.

Counter of occurrence of enhanced resonance of the twin flywheel of the engine 2008_CNT_OCCURRENCE

  • Service 22DID D4E4
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Counter of occurrence of resonance of the twin flywheel of the engine 2008_CNT_OCCURRENCE_RESONANCE

  • Service 22DID D4E5
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Rear left wheel speed 2008_RL_WHL_SPD

  • Service 22DID D531
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2013 to 2026.

Rear right wheel speed 2008_RR_WHL_SPD

  • Service 22DID D532
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2013 to 2026.

Transmission

Activation count, additional oil pump, ATN8 gearbox 2008_NUM_ADDITIONAL_OIL

  • Service 22DID D750
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, clutch electromagnetic valve C2 2008_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2

  • Service 22DID D743
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, clutch electromagnetic valve C3 2008_NUM_ACTIVATIONS_CLU_C3

  • Service 22DID D744
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, clutch protection C1 2008_NUM_ACTIVATIONS_CLU_C1

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Activation count, clutch protection C2 2008_NUM_ACTIVATIONS_CLU_C2

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Activation count, gear 7 2008_NUM_ACTIVATIONS_GEAR_7

  • Service 22DID D75B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, shift solenoid SC2 2008_NUM_SHIFT_SOLENOID

  • Service 22DID D752
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, shift solenoid SC3 2008_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3

  • Service 22DID D753
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 2008_NUM_ACTIVATIONS_P

  • Service 22DID D758
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, the electromagnetic valve of clutch C4 2008_NUM_ACTIVATIONS_C4

  • Service 22DID D759
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, the electromagnetic valve of the clutch C1 2008_NUM_ACTIVATIONS_C1

  • Service 22DID D742
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation count, torque converter lockup electromagnetic valve 2008_NUM_ACTIVATIONS_TQ

  • Service 22DID D746
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Activation of additional oil pump, ATN8 gearbox 2008_ACTIVATION

  • Service 22DID D616
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Additional oil pump control status, atn8 transmission 2008_ADDITIONAL_OIL_PMP

  • Service 22DID D617
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic restart request from transmission computer 2008_AUTOMATIC_RESTART_REQ

  • Service 22DID D70B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic stop allowed by gearbox computer 2008_AUTOMATIC_STOP_ALLOWED

  • Service 22DID D704
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic transmission fluid temperature 2008_AUTOMATIC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D550
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Automatic transmission in emergency mode 2008_AUTOMATIC_TRANS_EMERGENCY

  • Service 22DID D670
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic transmission in park position 2008_AUTOMATIC_TRANS_PARK

  • Service 22DID D70B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic transmission input shaft mode, calculated 2008_AUTOMATIC_TRANS_INPUT_SHFT_MODE

  • Service 22DID D651
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2013 to 2026.

Automatic transmission input shaft mode, measured 2008_AUTOMATIC_TRANS_INPUT_SHFT

  • Service 22DID D650
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2013 to 2026.

Automatic transmission lubrication solenoid control current 2008_AUTOMATIC_TRANS_LUBRICATION

  • Service 22DID D61A
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic transmission oil aging sensor 2008_AUTOMATIC_TRANS_OIL

  • Service 22DID D405
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Automatic transmission oil drain 2008_DRAIN_TRANS

  • Service 22DID D509
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic transmission output shaft mode, calculated 2008_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE

  • Service 22DID D653
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64−8128
Range
-8128 to 4186112 rpm
Unit
rpm

In testing for 2013 to 2026.

Automatic transmission output shaft mode, measured 2008_AUTOMATIC_TRANS_OUTPUT

  • Service 22DID D652
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2013 to 2026.

Automatic transmission overheat indicator request 2008_AUTOMATIC_TRANS

  • Service 22DID D510
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Automatic transmission torque request 2008_AUTOMATIC_TRANS_TQ

  • Service 22DID D508
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2013 to 2026.

Calculated gear in gearbox 2008_CALC_GEAR_GEARBOX

  • Service 22DID D409
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Clutch pedal 2008_CLU_PEDAL

  • Service 22DID D404
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Clutch pedal position value 2008_CLU_PEDAL_POS

  • Service 22DID D469
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2013 to 2026.

Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 2008_CTRL_CURRENT_P_P

  • Service 22DID D625
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 2008_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P

  • Service 22DID D61E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Control current of electromagnetic valve of change of pressure of torque converter lock-up 2008_CTRL_CURRENT_P

  • Service 22DID D61C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Control current of the electromagnetic valve for changing the gear shift SC2 2008_CTRL_CURRENT

  • Service 22DID D60A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Control current of the electromagnetic valve of change of pressure of clutch C3 2008_CTRL_CURRENT_P_C3

  • Service 22DID D614
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Control current of the electromagnetic valve of change of pressure of clutch C4 2008_CTRL_CURRENT_P_C4

  • Service 22DID D620
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Control current of the solenoid valve for changing the pressure of the clutch C1 2008_CTRL_CURRENT_P_C1

  • Service 22DID D610
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Control current of the solenoid valve for changing the pressure of the clutch C2 2008_CTRL_CURRENT_P_C2

  • Service 22DID D612
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

DC-DC converter temperature 2008_DC_DC_CONV_T

  • Service 22DID D8CE
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2013 to 2026.

Engaged gear 2008_ENGAGED_GEAR

  • Service 22DID D43D
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engaged gear 2008_ENGAGED_GEAR_6A9

  • Service 22DID D501
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Exhaust gas temperature after upstream catalytic converter 2008_EXH_GAS_T_AFTER_PRE

  • Service 22DID D555
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2013 to 2026.

Exhaust gas temperature before upstream catalytic converter 2008_EXH_GAS_T_BEFORE_PRE

  • Service 22DID D52E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2013 to 2026.

Gear in the process of engaging 2008_GEAR_PROCESS

  • Service 22DID D43E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Gear shift knob under steering wheel 2008_GEAR_SHIFT_KNOB

  • Service 22DID D520
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Gear shift lever position displayed on instrument panel 2008_GEAR_SHIFT_LEVER_POS_ON

  • Service 22DID D500
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Maximum clutch travel during gear shift 2008_MAX_CLU_TRAVEL

  • Service 22DID D498
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2013 to 2026.

Measured current of control of electromagnetic valve of automatic transmission lubrication 2008_MEAS_CURRENT_CTRL

  • Service 22DID D61B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 2008_MEAS_CURRENT_CTRL_P

  • Service 22DID D61D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Measured current of the electromagnetic valve for changing the gear shift SC2 2008_MEAS_CURRENT

  • Service 22DID D60B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 2008_MEAS_CURRENT_P_P

  • Service 22DID D626
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Measured current of the electromagnetic valve of change of pressure of clutch C3 2008_MEAS_CURRENT_P_C3

  • Service 22DID D615
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured current of the electromagnetic valve of change of pressure of clutch C4 2008_MEAS_CURRENT_P_C4

  • Service 22DID D621
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured current of the solenoid valve for changing the pressure of the clutch C1 2008_MEAS_CURRENT_P_C1

  • Service 22DID D611
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured current of the solenoid valve for changing the pressure of the clutch C2 2008_MEAS_CURRENT_P_C2

  • Service 22DID D613
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 2008_MEAS_CURRENT_P

  • Service 22DID D61F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Nitrogen oxide content after catalytic converter, ppm 2008_NOX_CONTENT_AFTER

  • Service 22DID D53D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2013 to 2026.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 2008_NOX_CONTENT_MEAS

  • Service 22DID D545
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2013 to 2026.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 2008_NOX_CONTENT_MEAS_INLET_NOX

  • Service 22DID D576
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2013 to 2026.

Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 2008_NUM_ENGAGEMENTS_P_P

  • Service 22DID D75D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 1 2008_NUM_GEAR_ENGAGEMENTS_1

  • Service 22DID D747
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 2 2008_NUM_GEAR_ENGAGEMENTS_2

  • Service 22DID D748
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 3 2008_NUM_GEAR_ENGAGEMENTS_3

  • Service 22DID D749
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 4 2008_NUM_GEAR_ENGAGEMENTS_4

  • Service 22DID D74A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 5 2008_NUM_GEAR_ENGAGEMENTS_5

  • Service 22DID D74B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 6 2008_NUM_GEAR_ENGAGEMENTS_6

  • Service 22DID D74C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements 8 2008_NUM_GEAR_ENGAGEMENTS_8

  • Service 22DID D75C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements n 2008_NUM_GEAR_ENGAGEMENTS_N

  • Service 22DID D74E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of gear engagements right 2008_NUM_GEAR_ENGAGEMENTS

  • Service 22DID D74D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of shift solenoid operated automatic transmission lubrication control valve 2008_NUM_SHIFT_SOLENOID_OPERATED

  • Service 22DID D756
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of shift solenoid operated SC4 2008_NUM_SHIFT_SOLENOID_OPERATED_SC4

  • Service 22DID D754
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of shift solenoid operated SC5 2008_NUM_SHIFT_SOLENOID_OPERATED_SC5

  • Service 22DID D755
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Number of shift solenoid operated torque converter lock-up pressure regulating valve 2008_NUM_SHIFT_SOLENOID_P

  • Service 22DID D757
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2013 to 2026.

Operating mode used by the automatic transmission 2008_OP_MODE_USED

  • Service 22DID D673
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Position of the gearshift lever 2008_POS_GEARSHIFT_LEVER

  • Service 22DID D700
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Proportional clutch pedal sensor 2008_PROPORTIONAL_CLU

  • Service 22DID D56E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Reverse gear contactor status 2008_REVERSE_GEAR

  • Service 22DID D43C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

SC5 shift solenoid control current 2008_SC5_SHIFT_SOLENOID

  • Service 22DID D618
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

SC5 shift solenoid measured current 2008_SC5_SHIFT_SOLENOID_MEAS

  • Service 22DID D619
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Shift solenoid control current SC3 2008_SHIFT_SOLENOID_CTRL

  • Service 22DID D60C
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Shift solenoid control current SC4 2008_SHIFT_SOLENOID_CTRL_CURRENT_SC4

  • Service 22DID D60E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Shift solenoid measured current SC3 2008_SHIFT_SOLENOID_MEAS

  • Service 22DID D60D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Shift solenoid measured current SC4 2008_SHIFT_SOLENOID_MEAS_CURRENT_SC4

  • Service 22DID D60F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Shift-lock control 2008_SHIFT_LOCK_CTRL

  • Service 22DID D701
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Start permission from gearbox computer 2008_START_PERMISSION

  • Service 22DID D41A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Torque converter lock-up pressure variation solenoid valve control current 2008_TQ_CONV_LOCK_UP_P

  • Service 22DID D604
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Torque converter lock-up pressure variation solenoid valve control current 2008_TQ_CONV_LOCK_UP_P_VARIATION

  • Service 22DID D605
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2013 to 2026.

Torque converter slip mode, theoretical value 2008_TQ_CONV_SLIP_MODE

  • Service 22DID D655
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2013 to 2026.

Torque converter status 2008_TQ_CONV_STAT

  • Service 22DID D504
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Upstream catalytic converter aging 2008_PRE_CATALYTIC_CONV

  • Service 22DID D559
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2013 to 2026.

Trips

Distance to next oil change 2008_DIST_NEXT_OIL_CHANGE

  • Service 22DID D536
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2026.

Distance traveled since the last regeneration 2008_DIST_TRAVELED_SINCE

  • Service 22DID D519
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val16
Range
0 to 4095 km
Unit
km

In testing for 2013 to 2026.

Odometer 2008_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Odometer 2008_ODO_6A2

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A2 → 682
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2013 to 2026.

Odometer 2008_ODO_6A6

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A6 → 686
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2013 to 2026.

Odometer 2008_ODO_6A9

Pelican can show this parameter as the odometer.

  • Service 22DID D802
  • Module6A9 → 689
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2013 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.