Parameters
The Peugeot 3008 has 544 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Accelerator pedal signal 1 voltage 3008_ACCEL_PEDAL_SIG_1_VConfirmed
- Service 22
DID D405 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
0x07DE = 2014 → = 0.4028 V
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Accelerator pedal signal 2 voltage 3008_ACCEL_PEDAL_SIG_2_VConfirmed
- Service 22
DID D406 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
0x0407 = 1031 → = 0.2062 V
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Approximate position of turbocharger actuator 3008_APPROXIMATE_POS
- Service 22
DID D4EC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Average cell voltage value 3008_AVG_CELL_V
- Service 22
DID D43D - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery average temperature 3008_BAT_AVG_T
- Service 22
DID D877 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 001 voltage 3008_BAT_CELL_001_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 002 voltage 3008_BAT_CELL_002_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 003 voltage 3008_BAT_CELL_003_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 004 voltage 3008_BAT_CELL_004_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 005 voltage 3008_BAT_CELL_005_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 006 voltage 3008_BAT_CELL_006_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 007 voltage 3008_BAT_CELL_007_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 008 voltage 3008_BAT_CELL_008_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 009 voltage 3008_BAT_CELL_009_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 010 voltage 3008_BAT_CELL_010_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 011 voltage 3008_BAT_CELL_011_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 012 voltage 3008_BAT_CELL_012_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 013 voltage 3008_BAT_CELL_013_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 014 voltage 3008_BAT_CELL_014_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 015 voltage 3008_BAT_CELL_015_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 016 voltage 3008_BAT_CELL_016_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 017 voltage 3008_BAT_CELL_017_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 018 voltage 3008_BAT_CELL_018_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 019 voltage 3008_BAT_CELL_019_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 020 voltage 3008_BAT_CELL_020_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 021 voltage 3008_BAT_CELL_021_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 022 voltage 3008_BAT_CELL_022_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 023 voltage 3008_BAT_CELL_023_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 024 voltage 3008_BAT_CELL_024_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 025 voltage 3008_BAT_CELL_025_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 026 voltage 3008_BAT_CELL_026_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 027 voltage 3008_BAT_CELL_027_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 028 voltage 3008_BAT_CELL_028_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 029 voltage 3008_BAT_CELL_029_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 030 voltage 3008_BAT_CELL_030_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 031 voltage 3008_BAT_CELL_031_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 032 voltage 3008_BAT_CELL_032_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 033 voltage 3008_BAT_CELL_033_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 034 voltage 3008_BAT_CELL_034_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 035 voltage 3008_BAT_CELL_035_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 036 voltage 3008_BAT_CELL_036_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 037 voltage 3008_BAT_CELL_037_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 038 voltage 3008_BAT_CELL_038_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 039 voltage 3008_BAT_CELL_039_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 040 voltage 3008_BAT_CELL_040_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 041 voltage 3008_BAT_CELL_041_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 042 voltage 3008_BAT_CELL_042_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 043 voltage 3008_BAT_CELL_043_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 044 voltage 3008_BAT_CELL_044_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 045 voltage 3008_BAT_CELL_045_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 046 voltage 3008_BAT_CELL_046_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 047 voltage 3008_BAT_CELL_047_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 048 voltage 3008_BAT_CELL_048_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 049 voltage 3008_BAT_CELL_049_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 050 voltage 3008_BAT_CELL_050_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 051 voltage 3008_BAT_CELL_051_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 052 voltage 3008_BAT_CELL_052_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 053 voltage 3008_BAT_CELL_053_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 054 voltage 3008_BAT_CELL_054_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 055 voltage 3008_BAT_CELL_055_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 056 voltage 3008_BAT_CELL_056_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 057 voltage 3008_BAT_CELL_057_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 058 voltage 3008_BAT_CELL_058_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 059 voltage 3008_BAT_CELL_059_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 060 voltage 3008_BAT_CELL_060_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 061 voltage 3008_BAT_CELL_061_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 062 voltage 3008_BAT_CELL_062_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 063 voltage 3008_BAT_CELL_063_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 064 voltage 3008_BAT_CELL_064_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 065 voltage 3008_BAT_CELL_065_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 066 voltage 3008_BAT_CELL_066_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 067 voltage 3008_BAT_CELL_067_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 068 voltage 3008_BAT_CELL_068_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 069 voltage 3008_BAT_CELL_069_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 070 voltage 3008_BAT_CELL_070_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 071 voltage 3008_BAT_CELL_071_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 072 voltage 3008_BAT_CELL_072_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 073 voltage 3008_BAT_CELL_073_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 074 voltage 3008_BAT_CELL_074_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 075 voltage 3008_BAT_CELL_075_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 076 voltage 3008_BAT_CELL_076_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 077 voltage 3008_BAT_CELL_077_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 078 voltage 3008_BAT_CELL_078_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 079 voltage 3008_BAT_CELL_079_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 080 voltage 3008_BAT_CELL_080_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 081 voltage 3008_BAT_CELL_081_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 082 voltage 3008_BAT_CELL_082_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 083 voltage 3008_BAT_CELL_083_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 084 voltage 3008_BAT_CELL_084_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 085 voltage 3008_BAT_CELL_085_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 086 voltage 3008_BAT_CELL_086_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 087 voltage 3008_BAT_CELL_087_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 088 voltage 3008_BAT_CELL_088_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 089 voltage 3008_BAT_CELL_089_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 090 voltage 3008_BAT_CELL_090_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 091 voltage 3008_BAT_CELL_091_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 092 voltage 3008_BAT_CELL_092_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 093 voltage 3008_BAT_CELL_093_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 094 voltage 3008_BAT_CELL_094_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 095 voltage 3008_BAT_CELL_095_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 096 voltage 3008_BAT_CELL_096_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 097 voltage 3008_BAT_CELL_097_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,536 to 1,551 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 098 voltage 3008_BAT_CELL_098_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,552 to 1,567 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 099 voltage 3008_BAT_CELL_099_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,568 to 1,583 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 100 voltage 3008_BAT_CELL_100_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,584 to 1,599 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 101 voltage 3008_BAT_CELL_101_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,600 to 1,615 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 102 voltage 3008_BAT_CELL_102_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,616 to 1,631 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 103 voltage 3008_BAT_CELL_103_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,632 to 1,647 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 104 voltage 3008_BAT_CELL_104_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,648 to 1,663 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 105 voltage 3008_BAT_CELL_105_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,664 to 1,679 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 106 voltage 3008_BAT_CELL_106_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,680 to 1,695 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 107 voltage 3008_BAT_CELL_107_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,696 to 1,711 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 108 voltage 3008_BAT_CELL_108_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,712 to 1,727 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 109 voltage 3008_BAT_CELL_109_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,728 to 1,743 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 110 voltage 3008_BAT_CELL_110_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,744 to 1,759 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 111 voltage 3008_BAT_CELL_111_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,760 to 1,775 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 112 voltage 3008_BAT_CELL_112_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,776 to 1,791 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 113 voltage 3008_BAT_CELL_113_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,792 to 1,807 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 114 voltage 3008_BAT_CELL_114_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,808 to 1,823 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 115 voltage 3008_BAT_CELL_115_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,824 to 1,839 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 116 voltage 3008_BAT_CELL_116_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,840 to 1,855 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 117 voltage 3008_BAT_CELL_117_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,856 to 1,871 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 118 voltage 3008_BAT_CELL_118_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,872 to 1,887 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 119 voltage 3008_BAT_CELL_119_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,888 to 1,903 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery cell 120 voltage 3008_BAT_CELL_120_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,904 to 1,919 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery current 3008_BAT_CURRENTConfirmed
- Service 22
DID D497 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2097152 to 2097151 A
- Unit
- A
0x0000003D = 61 → = 0.05957 A
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Battery DC current 3008_BAT_DC_CURRENT
- Service 22
DID D816 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -1200 to 67107663 A
- Unit
- A
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery insulation resistance 3008_BAT_INSULATION_RES
- Service 22
DID D47A - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 kΩ
- Unit
- kΩ
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery max unit temperature 3008_BAT_MAX_UNIT_T
- Service 22
DID D817 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery max unit temperature number 3008_BAT_MAX_UNIT_T_NUMBER
- Service 22
DID D445 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery min unit temperature 3008_BAT_MIN_UNIT_T
- Service 22
DID D87D - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery min unit temperature number 3008_BAT_MIN_UNIT_T_NUMBER
- Service 22
DID D446 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Battery temperature 3008_BAT_T
- Service 22
DID D8EF - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Cell voltage sum 3008_CELL_V_SUMM
- Service 22
DID D438 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Centralized voltage maintenance device temperature limiter state 3008_CENTRALIZED_V_T
- Service 22
DID D759 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Computer power supply voltage 3008_COMPUTER_POWER_SUP_VConfirmed
- Service 22
DID D551 - Module
6A9 → 689 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x8B = 139 → = 13.9 V
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Energy accumulator discharge permission state 3008_ENERGY_ACCUMULATOR
- Service 22
DID D74F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Engine control computer supply voltage 3008_ENG_CTRL_COMPUTER_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D422 - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 V
- Unit
- V
0x0568 = 1384 → = 13.84 V
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine oil level sensor voltage 3008_ENG_OIL_LEVEL_SENS_VConfirmed
- Service 22
DID D41E - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
0x0EE2 = 3810 → = 762 mV
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Evaluation of the total resistance of the voltage maintaining device 3008_EVALUATION_TOT_RES_V
- Service 22
DID D72D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.511
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
High voltage battery charge 3008_HVBAT_SOC_RAW
Pelican can show this parameter as the state of charge.
- Service 22
DID D810 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
High voltage battery charge, calibrated 3008_HVBAT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID D410 - Module
6B4 → 694 - Every
1 s - Testing for 2008 to 2023, 2025 to 2026
Example reply from a 2024 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2024. In testing for 2008 to 2016, 2020, 2022, 2026. Not supported for 2017 to 2019, 2021, 2023, 2025.
High voltage battery health 3008_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Service 22
DID D860 - Module
6B4 → 694 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
High voltage battery voltage 3008_HVBAT_VOLT
- Service 22
DID D815 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
High voltage maximum voltage 3008_HVBAT_MAX_VOLT
- Service 22
DID D870 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
High voltage minimum voltage 3008_HVBAT_MIN_VOLT
- Service 22
DID D86F - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Highest voltage cell number 3008_HIGHEST_V_CELL
- Service 22
DID D43B - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
HV battery energy 3008_HVBAT_KWH
Energy stored in the high voltage battery
- Service 22
DID D865 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 kWh
- Unit
- kWh
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Lowest voltage cell number 3008_LOWEST_V_CELL_NUMBER
- Service 22
DID D43C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Maximum power the battery can provide for 10 seconds 3008_MAX_POWER_BAT_CAN_PROVIDE_10
- Service 22
DID D873 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Maximum power the battery can provide for 30 seconds 3008_MAX_POWER_BAT_CAN_PROVIDE_30
- Service 22
DID D874 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Maximum power the battery can withstand for 10 seconds 3008_MAX_POWER_BAT_CAN_10
- Service 22
DID D871 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Maximum power the battery can withstand for 30 seconds 3008_MAX_POWER_BAT_CAN_30
- Service 22
DID D872 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Minimum battery voltage at startup 3008_MIN_BAT_V_STARTUP
- Service 22
DID D4D4 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
On-board charger temperature 3008_ON_BOARD_CHARGER_T
- Service 22
DID D8E1 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Reversible generator voltage 3008_REVERSIBLE_GEN_V
- Service 22
DID D713 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Service battery charge state 3008_SERVICE_BAT_CHG_STConfirmed
- Service 22
DID D742 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Service battery charge status 3008_SERVICE_BAT_CHG_STATConfirmed
- Service 22
DID D467 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
0x04D8 = 1240 → = 77.5 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Service battery temperature 3008_SERVICE_BAT_T
- Service 22
DID D496 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Service battery temperature 3008_SERVICE_BAT_T_6A8Confirmed
- Service 22
DID D496 - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
0x0052 = 82 → = 41 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Service battery voltage 3008_SERVICE_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D78A - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
0x06F4 = 1780 → = 13.90625 V
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Service battery wear condition 3008_SERVICE_BAT_WEARConfirmed
- Service 22
DID D741 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Service cell voltage value 3008_SERVICE_CELL_V
- Service 22
DID D822 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Set voltage of energy storage 3008_SET_V_ENERGY_STORAGE
- Service 22
DID D734 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Set voltage of storage battery charging 3008_SET_V_STORAGE_BATConfirmed
- Service 22
DID D766 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
0x0718 = 1816 → = 14.1875 V
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Set voltage of the reversible generator 3008_SET_V_REVERSIBLE_GEN
- Service 22
DID D712 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 16.97 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Stop permitted by voltage maintainer computer 3008_STOP_PERMITTED_V
- Service 22
DID D749 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Temperature of the electronic power unit of the voltage maintenance device 3008_T_ELECTRONIC_POWER_V
- Service 22
DID D730 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Turbocharger control duty cycle 3008_TURBOCHARGER_CTRLConfirmed
- Service 22
DID D48A - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -128 to 127 %
- Unit
- %
0x391C = 14620 → = 57.109375 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Turbocharger first electronic boost 3008_TURBOCHARGER_FIRST
- Service 22
DID D48C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Turbocharger position information 3008_TURBOCHARGER_POS
- Service 22
DID D4EA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Turbocharger pressure measured 3008_TURBOCHARGER_P_MEASConfirmed
- Service 22
DID D4D9 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
0x1162 = 4450 → 4,450
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Turbocharger pressure reference 3008_TURBOCHARGER_P
- Service 22
DID D556 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Turbocharger, target position 3008_TURBOCHARGER_TGT_POS
- Service 22
DID D47B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Voltage at the terminals of the energy accumulator 3008_V_TERMINALS_ENERGY
- Service 22
DID D720 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Voltage maintainer computer request sent 3008_V_MAINTAINER_COMPUTER_REQ
- Service 22
DID D748 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Voltage maintainer computer restart permission 3008_V_MAINTAINER
- Service 22
DID D747 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Voltage maintainer status 3008_V_MAINTAINER_STAT
- Service 22
DID D72C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Control
Anti-lock brake or stability control regulating 3008_ABS_EKS_PROCESS_ADJ
- Service 22
DID D474 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Brake circuit pressure 3008_BRAKE_CIRCUIT_P
- Service 22
DID D70E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -55 to 6498 bar
- Unit
- bar
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Brake system backup contactor status 3008_BRAKE_SYSTEM_BACKUPConfirmed
- Service 22
DID D463 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Main brake contactor status 3008_MAIN_BRAKE_CONTACTORConfirmed
- Service 22
DID D513 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Secondary brake contactor status 3008_SECONDARY_BRAKEConfirmed
- Service 22
DID D514 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vacuum present in the brake system 3008_VACUUM_PRESENT_BRAKEConfirmed
- Service 22
DID D700 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2023. Supported for 2017 to 2019, 2021.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2023. Supported for 2017 to 2019, 2021.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Engine
5V power supply state number 1 3008_5V_POWER_SUP_ST_1Confirmed
- Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
5V power supply state number 2 3008_5V_POWER_SUP_ST_2Confirmed
- Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
5V power supply state number 3 3008_5V_POWER_SUP_ST_3Confirmed
- Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
5V power supply state number 4 3008_5V_POWER_SUP_ST_4
- Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
12V network allowed stop 3008_12V_NETWORK_ALLOWEDConfirmed
- Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, brake electromagnetic valve B1 3008_NUM_ACTIVATIONS_B1Confirmed
- Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0004C4B9 = 312505 → 312,505
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, line pressure control solenoid 3008_NUM_LINE_P_CTRL
- Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Activation count, the electromagnetic valve of brake B2 3008_NUM_ACTIVATIONS_B2
- Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Actual oil pressure 3008_ACT_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Additional heater control 1 3008_ADDITIONAL_HEATER_1
- Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Air conditioning 3008_ACConfirmed
- Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Air conditioning compressor current 3008_AC_COMP_CURRENTConfirmed
- Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375
- Unit
- Number
0x0D = 13 → = 325
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Air conditioning high side pressure 3008_AC_HIGH_SIDE_P
- Service 22
DID D8FF - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Air conditioning pressure 3008_AC_PConfirmed
- Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
0x4386 = 17286 → = 17.286 bar
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Air doser first electronic loading 3008_AIR_DOSER_FIRST
- Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Air flow 3008_AIR_FLOWConfirmed
- Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
0x008C = 140 → = 14
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2017, 2023. Supported for 2018 to 2019, 2021.
Air flow target 3008_AIR_FLOW_TGTConfirmed
- Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
0x00CA = 202 → = 20.2
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Air metering valve duty cycle 3008_AIR_METERING_VLV
- Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Air metering valve position 3008_AIR_METERING_VLV_POS
- Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Air metering valve, target position 3008_AIR_METERING_VLV_TGTConfirmed
- Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
0x0940 = 2368 → = 23.679999 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Air temperature by air flow meter 3008_AIR_T_AIR_FLOW_METER
- Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Alternator load value 3008_ALTERNATOR_LOADConfirmed
- Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x13 = 19 → 19 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Ambient air temperature 3008_AAT_6A9Confirmed
- Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
0x96 = 150 → = 35 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Ambient temperature 3008_AAT
- Service 22
DID D434 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
ANTI START PROGRAMMING STATUS 3008_ANTI_START
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Atmospheric pressure 3008_ATMOSPHERIC_PConfirmed
- Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
0x03E9 = 1001 → 1,001
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic restart request from body control module 3008_AUTOMATIC_RESTART_REQ_BSIConfirmed
- Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic restart request from engine management computer 3008_AUTOMATIC_RESTARTConfirmed
- Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic stop allowed by body control module 3008_AUTOMATIC_STOPConfirmed
- Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic stop allowed by power steering computer 3008_AUTOMATIC_STOP_ALLOWED_POWER_STEERConfirmed
- Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Auxiliary heater 2 control 3008_AUXILIARY_HEATER_2
- Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Average mileage for the last 10 regenerations 3008_AVG_MILEAGE_LAST_10
- Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Boost air temperature 3008_BOOST_AIR_T
- Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Button state 3008_BUTTON_ST
- Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2023. Supported for 2018 to 2019, 2021, 2024 to 2025.
Camshaft/crankshaft position synchronization 3008_CAM_CRANK_POS
- Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
CHANGE REPORT IN PROGRESS 3008_CHANGE_REPORTConfirmed
- Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Combustion engine state 3008_ICE_ST
- Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2017 to 2019, 2021.
Commanded oil pressure 3008_CMD_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Computer lock 3008_COMPUTER_LOCK
- Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Computer remote wake-up state 3008_COMPUTER_WAKE_UP_STConfirmed
- Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Computer restarts since memory erase 3008_CNT_NUM_RE
- Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Computer temperature 3008_COMPUTER_TConfirmed
- Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0CE7 = 3303 → 3,303 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Control current of electromagnetic valve for changing the pressure in the brake system B2 3008_CTRL_CURRENT_P_B2
- Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 3008_CTRL_CURRENT_P_B1Confirmed
- Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x0A = 10 → = 100 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Controlled air supply module 3008_CONTROLLED_AIR_SUPConfirmed
- Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Coolant temperature 3008_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D8FB - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Coolant temperature 3008_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Coolant temperature target 3008_ECT_TGTConfirmed
- Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0055 = 85 → 85 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Coolant temperature, corrected 3008_ECT_CORRECTEDConfirmed
- Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0057 = 87 → 87 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Cruise control, RW status 3008_CRUISE_CTRL_RW_STATConfirmed
- Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x02 = 2 → 2
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Cylinder 1 injector flow correction 3008_CYL_1_INJ_FLOW_CORR
- Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Cylinder 2 injector flow correction 3008_CYL_2_INJ_FLOW_CORR
- Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Cylinder 3 injector flow correction 3008_CYL_3_INJ_FLOW_CORR
- Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Cylinder 4 injector flow correction 3008_CYL_4_INJ_FLOW_CORR
- Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Date 3008_DATEConfirmed
- Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
0x02EEF35B = 49214299 → = 4,921,429.9 s
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Drive motor coolant inlet temperature 3008_DRIVE_MOTOR_CLT_T
- Service 22
DID D8D6 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Drive motor power 3008_DRIVE_MOTOR_POWER
- Service 22
DID D8D9 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 W
- Unit
- W
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Drive motor stator temperature 3008_DRIVE_MOTOR_STATOR_T
- Service 22
DID D8CD - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Drive motor torque, actual 3008_DRIVE_MOTOR_TQ_ACT
- Service 22
DID D8D0 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Drive motor torque, desired 3008_DRIVE_MOTOR_TQ_DES
- Service 22
DID D880 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 N·m
- Unit
- N·m
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Driver presence 3008_DRIVER_PRESENCEConfirmed
- Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Driver, requested torque value 3008_DRIVER_REQ_TQConfirmed
- Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
0x23 = 35 → = -30 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Economy mode off state 3008_ECO_MODE_OFF_STConfirmed
- Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2023. Supported for 2017 to 2019, 2021.
Electric cooling fan control 3008_GMV_ELEC_COOLING_FANConfirmed
- Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Electric machine torque 3008_ELEC_MACHINE_TQ
- Service 22
DID DCB6 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1638 to 4915 N·m
- Unit
- N·m
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Electric machine torque reduction 3008_ELEC_MACHINE_TQ_REDUCTION
- Service 22
DID DC69 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Energy accumulator state transfer 3008_ENERGY_ACCUMULATOR_ST
- Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Energy accumulator temperature limiter state 3008_ENERGY_ACCUMULATOR_T
- Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Engine control module status 3008_ENG_CTRL_MODULE_STATConfirmed
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine coolant temperature 3008_ECT_6A9Confirmed
- Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x7E = 126 → = 86 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Engine oil dilution protection status 3008_ENG_OIL_DILUTION
- Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Engine operating mode 3008_ENG_OP_MODEConfirmed
- Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 rpm
- Unit
- rpm
0x18C8 = 6344 → = 793 rpm
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine restart counter 3008_ENG_RESTART_CNT
- Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Engine restart counter by stop and start function 3008_ENG_RESTART_CNT_STOP
- Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Engine restart request sent by ESP computer 3008_ENG_RESTART_REQ_SENTConfirmed
- Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Engine stalls 3008_ENG_STALLSConfirmed
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine start prohibition control, start lock 3008_ENG_STARTConfirmed
- Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine stop time 3008_ENG_STOP_TIMEConfirmed
- Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 s
- Unit
- s
0x000066EA = 26346 → 26,346 s
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine torque 3008_ENG_TQ
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Estimated torque of internal friction of the engine 3008_ESTIMATED_TQConfirmed
- Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
0x0100 = 256 → = 16 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Evaluation of carbon content in engine oil 3008_EVALUATION_CARBON
- Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Evaluation of the degree of dilution of motor oil 3008_EVALUATION_DEGREE
- Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas recirculation high limit electronic loading 3008_EGR_HIGH_LIM
- Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas recirculation low limit electronic loading 3008_EGR_LOW_LIM
- Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas recirculation valve duty cycle 3008_EGR_VLV_CTRL_SIG_RCO
- Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas recirculation valve first electronic loading 3008_EGR_VLV_FIRST
- Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas recirculation valve position 3008_EGR_VLV_POS
- Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas recirculation valve set position 3008_EGR_VLV_SET_POS
- Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Expected generator supplier identifier of the reversible generator 3008_EXPECTED_GEN
- Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Expected identifier of electronic power circuit of reversible generator generator 3008_EXPECTED_IDENTIFIER_ELECTRONIC
- Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Expected identifier of reversible generator 3008_EXPECTED_IDENTIFIER
- Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
FUGITIVE TRIP IN EMERGENCY MODE 3008_FUGITIVE_TRIPConfirmed
- Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Generator mode 3008_GEN_MODE
- Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Generator shutdown 3008_GEN_SHUTDOWN
- Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Identifier of the electronic power circuit of the reversible generator 3008_IDENTIFIER
- Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Identifier of the supplier of the reversible generator 3008_IDENTIFIER_SUPPLIER
- Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Immobilizer code programming status 3008_IMMOBILIZER_CODEConfirmed
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Indicated engine torque 3008_INDICATED_ENG_TQConfirmed
- Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Injector code 1 3008_INJ_CODE_1
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Injector code 2 3008_INJ_CODE_2
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Injector code 3 3008_INJ_CODE_3
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Injector code 4 3008_INJ_CODE_4
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Inverter temperature estimated 3008_INVERTER_T_ESTIMATED
- Service 22
DID DC6A - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Inverter temperature, commanded 3008_INVERTER_T_CMD
- Service 22
DID DC04 - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Line pressure solenoid valve control current 3008_SLT_LINE_P_VARIATIONConfirmed
- Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x4A = 74 → = 740 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Lock status 3008_LOCK_STATConfirmed
- Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Long-term regeneration capability 3008_LONG_TERM_REGEN
- Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Maximum allowable torque 3008_MAX_ALLOWABLE_TQConfirmed
- Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
0x34 = 52 → = 4 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 3008_MEAS_CURRENT_P_B2
- Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 3008_MEAS_CURRENT_P_B1Confirmed
- Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x09 = 9 → = 90 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Measured line pressure variation solenoid valve current 3008_MEAS_LINE_PConfirmed
- Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x49 = 73 → = 730 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Mileage since last oil change 3008_MILEAGE_SINCE_OIL
- Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Minimum cell capacity 3008_MIN_CELL_CAP
- Service 22
DID D413 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Movement of controlled air supply module 3008_MOVEMENT_CONTROLLED
- Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Neutral position sensor status 3008_NEUTRAL_POS_SENSConfirmed
- Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of engine stop information deletion cycles 3008_NUM_ENG_STOPConfirmed
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Oil pressure 3008_OIL_PConfirmed
- Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
0x0169 = 361 → = 0.361 bar
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Oil pressure reference value 3008_OIL_P_REFERENCEConfirmed
- Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
0x0A4A = 2634 → = 2.634 bar
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Oil pressure regulation control 3008_OIL_P_REGULATION
- Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Oil temperature 3008_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
0x03B8 = 952 → = -177.940015 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Outside air temperature 3008_AAT_6A8Confirmed
- Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0022 = 34 → 34 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Powertrain condition 3008_POWERTRAIN_CONDConfirmed
- Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Preheating relay control 3008_PREHEATING_RELAY
- Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Presence of the identifier of the reversible generator 3008_PRESENCE_IDENTIFIER
- Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Problems detected while transmitting unlock code 3008_PROBLEMS_DETECTEDConfirmed
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Problems detected while transmitting unlock code 3008_PROBLEMS_DETECTED_WHILE
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Real engine torque 3008_REAL_ENG_TQConfirmed
- Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
0x24 = 36 → = -28 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Regeneration enable 3008_REGEN_ENABLE
- Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Remote wake-up circuit status 3008_REMOTE_WAKE_UPConfirmed
- Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Remote wake-up state 3008_REMOTE_WAKE_UP_ST
- Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Request to turn on the engine diagnostic indicator 3008_REQ_TURN_ON_ENGConfirmed
- Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Requested value controlled thermostat 3008_REQ_CONTROLLED
- Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Restart request sent by power steering computer 3008_RESTART_REQ_SENTConfirmed
- Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Restart request sent by suspension computer 3008_RESTART_REQ_SENT_SUSPENSIONConfirmed
- Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Return to engine start and restart control by starter 3008_RETURN_ENG_STARTConfirmed
- Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x02 = 2 → 2
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Return to starter engine restart control 3008_RETURN_STARTER_ENGConfirmed
- Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x02 = 2 → 2
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Reverse generator status 3008_REVERSE_GEN_STAT
- Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Reversible generator torque 3008_REVERSIBLE_GEN_TQ
- Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Service network related engine restart request 3008_SERVICE_NETWORKConfirmed
- Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Short-term regeneration capability 3008_SHORT_TERM_REGEN
- Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Sport mode contactor state 3008_SPORT_MODE_CONTACTORConfirmed
- Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Start inhibit control, wired 3008_START_INHIBIT_CTRLConfirmed
- Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Start or restart inhibition transmitted by engine management computer 3008_START_OR_RESTARTConfirmed
- Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Start prohibition 3008_START_PROHIBITIONConfirmed
- Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Starter activation counter 3008_STARTER_ACTIVATIONConfirmed
- Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x000032BE = 12990 → 12,990
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Starter control interface unit operating status 3008_STARTER_CTRLConfirmed
- Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Starter duty cycle 3008_STARTER_DUTYConfirmed
- Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
0x0000 = 0 → = 0 s
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Starter engagement status 3008_STARTER_ENGAGEMENTConfirmed
- Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
State lock/unlock control unit 3008_ST_LOCK_UNLOCK_CTRL
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Status of internal ignition motor 3008_STAT_INTERNAL_IGNConfirmed
- Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x05 = 5 → 5
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Status of the energy accumulator 3008_STAT_ENERGY
- Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Stop allowed by ESP computer 3008_STOP_ALLOWED_ESPConfirmed
- Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Stop and start function state 3008_STOP_START_FUNCTIONConfirmed
- Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x09 = 9 → 9
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Stop and start switch 3008_STOP_START_SWITCHConfirmed
- Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Stop permitted by suspension computer 3008_STOP_PERMITTEDConfirmed
- Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Temperature difference between the hottest and the coolest cells 3008_T_DIFF_HOTEST
- Service 22
DID D878 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Temperature of the energy accumulator 3008_T_ENERGY_ACCUMULATOR
- Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
The composition of the mixture is calculated by the oxygen sensor 3008_COMPOSITION_MIXTURE
- Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Torque corresponding to driver requirement 3008_TQ_CORRESPONDINGConfirmed
- Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
0x0096 = 150 → = 9.375 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Torque supplied or taken by generator 3008_TQ_SUPPLIED_OR_TAKENConfirmed
- Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
0x005B = 91 → = 5.6875 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Total mileage 3008_ODO_6A8Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
0x00037BA0 = 228256 → 228,256 km
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Towing device configured 3008_CAN_VEH_BE_EQUIPPED
- Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Traction circuit coolant temperature 3008_TRACTION_CIRCUIT_ECT
- Service 22
DID D8F9 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Traction or stability control regulating 3008_ASR_OR_ESP_SYSTEMConfirmed
- Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Transmission fluid temperature 3008_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2023. Supported for 2018 to 2019, 2021, 2025.
Vacuum circuit vacuum 3008_VACUUM_CIRCUIT
- Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Value during generator load smooth increase 3008_DURING_GEN_LOADConfirmed
- Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x07 = 7 → 7
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vehicle hour meter 3008_VEH_HOUR_METERConfirmed
- Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
0x02EEF3DD = 49214429 → = 4,921,442.9 s
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vehicle mileage since the last oil change under severe vehicle operating conditions 3008_VEH_MILEAGE_SINCE
- Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Winter mode switch state 3008_WINTER_MODE_SWITCHConfirmed
- Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Fuel
Amount of fuel additive remaining in the additive tank 3008_AMOUNT_FUEL_ADDITIVE
- Service 22
DID D56C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Calculated fuel injection amount 3008_CALC_FUEL_INJ_AMOUNT
- Service 22
DID D563 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Desired high pressure common rail fuel pressure 3008_DES_HIGH_P_COMMON_PConfirmed
- Service 22
DID D445 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 bar
- Unit
- bar
0x0320 = 800 → 800 bar
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
First fuel additive injection state 3008_FIRST_FUEL_ADDITIVE
- Service 22
DID D56F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Fuel pressure 3008_FUEL_P
- Service 22
DID D41F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Fuel temperature 3008_FUEL_T
- Service 22
DID D42A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
High fuel pressure measured 3008_HIGH_FUEL_P_MEASConfirmed
- Service 22
DID D446 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
0x031E = 798 → = 79.8 bar
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Injection angle of the high-pressure fuel pump 3008_INJ_ANG_HIGH_P_FUEL
- Service 22
DID D588 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Low pressure fuel pump actuator duty cycle 3008_LOW_P_FUEL_PMPConfirmed
- Service 22
DID D472 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
0x0015 = 21 → = 0.21 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Low pressure fuel pump status 3008_LOW_P_FUEL_PMP_STAT
- Service 22
DID D4ED - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Minimum fuel level 3008_MIN_FLI
- Service 22
DID D56A - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Movement
Accelerator pedal position 3008_ACCEL_PEDAL_POS
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.45 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Accelerator pedal position 3008_ACCEL_PEDAL_POS_6A6
- Service 22
DID D407 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Accelerator pedal position 3008_ACCEL_PEDAL_POS_6A9Confirmed
- Service 22
DID D505 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Accelerator pedal position 3008_ACCEL_PEDAL_POS_6B4
- Service 22
DID D407 - Module
6B4 → 694 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Accelerator pedal position, recalculated 3008_ACCEL_PEDAL_POS_RECALCULATEDConfirmed
- Service 22
DID D407 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Accelerator pedal position, track 1 3008_ACCEL_PEDAL_POS_1Confirmed
- Service 22
DID D491 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Accelerator pedal position, track 2 3008_ACCEL_PEDAL_POS_2Confirmed
- Service 22
DID D492 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Clutch release state at stop, creep speed reduction 3008_CLU_RELEASE_ST_STOPConfirmed
- Service 22
DID D672 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Crankshaft speed 3008_CRANK_SPD
- Service 22
DID D462 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Crankshaft speed determined by camshaft sensor 3008_CRANK_SPD_DETERMINEDConfirmed
- Service 22
DID D499 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
0x0631 = 1585 → = 792.5 rpm
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Cruise control set speed 3008_CRUISE_CTRL_SET_SPDConfirmed
- Service 22
DID D475 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine RPM 3008_RPMConfirmed
Pelican can show this parameter as the engine speed.
- Service 22
DID D400 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0319 = 793 → 793 rpm
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engine RPM 3008_RPM_6A9
Pelican can show this parameter as the engine speed.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Input shaft speed 3008_INPUT_SHFT_SPD
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Motor speed 3008_MOTOR_SPD
- Service 22
DID DC00 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Set speed of electric cooling fan 3008_SET_SPD_ELEC_COOLINGConfirmed
- Service 22
DID D4AA - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x13 = 19 → 19 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
STATUS COMMANDS REGULATION OR LIMITATION SPEED 3008_STAT_COMMANDSConfirmed
- Service 22
DID D704 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x03 = 3 → 3
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Torque converter slip speed, measured 3008_TQ_CONV_SLIP_SPDConfirmed
- Service 22
DID D654 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
0x7E = 126 → = -64 rpm
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vehicle speed 3008_VSS
Pelican can show this parameter as the speed.
- Service 21
PID C8 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Vehicle speed 3008_VSS_6A2
Pelican can show this parameter as the speed.
- Service 22
DID D402 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Vehicle speed 3008_VSS_6A8Confirmed
Pelican can show this parameter as the speed.
- Service 22
DID D402 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vehicle speed 3008_VSS_6A9
Pelican can show this parameter as the speed.
- Service 22
DID D711 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Vehicle speed 3008_VSS_6B4
Pelican can show this parameter as the speed.
- Service 22
DID D802 - Module
6B4 → 694 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4194368 km/h
- Unit
- km/h
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2017, 2023. Supported for 2018 to 2019, 2021, 2024 to 2025.
Vehicle speed limiter set speed 3008_VSS_LIMITER_SET_SPDConfirmed
- Service 22
DID D476 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vehicle speed limiter status, LW 3008_VSS_LIMITER_STAT_LWConfirmed
- Service 22
DID D4C0 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x03 = 3 → 3
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Vehicle speed, ESP 3008_VSS_ESP
Pelican can show this parameter as the speed.
- Service 22
DID D802 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.
Tires
Average front wheel speed 3008_AVG_FRONT_WHL_SPDConfirmed
- Service 22
DID D530 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Average speed front wheels 3008_AVG_SPD_FRONT_WHEELSConfirmed
- Service 22
DID D533 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Counter of occurrence of enhanced resonance of the twin flywheel of the engine 3008_CNT_OCCURRENCE
- Service 22
DID D4E4 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Counter of occurrence of resonance of the twin flywheel of the engine 3008_CNT_OCCURRENCE_RESONANCE
- Service 22
DID D4E5 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Rear left wheel speed 3008_RL_WHL_SPDConfirmed
- Service 22
DID D531 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Rear right wheel speed 3008_RR_WHL_SPDConfirmed
- Service 22
DID D532 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Transmission
Activation count, additional oil pump, ATN8 gearbox 3008_NUM_ADDITIONAL_OILConfirmed
- Service 22
DID D750 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x00000000 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, clutch electromagnetic valve C2 3008_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2Confirmed
- Service 22
DID D743 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0001FD13 = 130323 → 130,323
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, clutch electromagnetic valve C3 3008_NUM_ACTIVATIONS_CLU_C3Confirmed
- Service 22
DID D744 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0006ED16 = 453910 → 453,910
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, clutch protection C1 3008_NUM_ACTIVATIONS_CLU_C1Confirmed
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, clutch protection C2 3008_NUM_ACTIVATIONS_CLU_C2Confirmed
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, gear 7 3008_NUM_ACTIVATIONS_GEAR_7
- Service 22
DID D75B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Activation count, shift solenoid SC2 3008_NUM_SHIFT_SOLENOID
- Service 22
DID D752 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Activation count, shift solenoid SC3 3008_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3
- Service 22
DID D753 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 3008_NUM_ACTIVATIONS_P
- Service 22
DID D758 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Activation count, the electromagnetic valve of clutch C4 3008_NUM_ACTIVATIONS_C4
- Service 22
DID D759 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Activation count, the electromagnetic valve of the clutch C1 3008_NUM_ACTIVATIONS_C1Confirmed
- Service 22
DID D742 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x00034839 = 215097 → 215,097
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation count, torque converter lockup electromagnetic valve 3008_NUM_ACTIVATIONS_TQConfirmed
- Service 22
DID D746 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0004D870 = 317552 → 317,552
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Activation of additional oil pump, ATN8 gearbox 3008_ACTIVATIONConfirmed
- Service 22
DID D616 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Additional oil pump control status, atn8 transmission 3008_ADDITIONAL_OIL_PMPConfirmed
- Service 22
DID D617 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic restart request from transmission computer 3008_AUTOMATIC_RESTART_REQConfirmed
- Service 22
DID D70B - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic stop allowed by gearbox computer 3008_AUTOMATIC_STOP_ALLOWEDConfirmed
- Service 22
DID D704 - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic transmission fluid temperature 3008_AUTOMATIC_ATF_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D550 - Module
6A9 → 689 - Every
5 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x75 = 117 → = 77 °C
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic transmission in emergency mode 3008_AUTOMATIC_TRANS_EMERGENCYConfirmed
- Service 22
DID D670 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic transmission in park position 3008_AUTOMATIC_TRANS_PARK
- Service 22
DID D70B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Automatic transmission input shaft mode, calculated 3008_AUTOMATIC_TRANS_INPUT_SHFT_MODE
- Service 22
DID D651 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Automatic transmission input shaft mode, measured 3008_AUTOMATIC_TRANS_INPUT_SHFT
- Service 22
DID D650 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Automatic transmission lubrication solenoid control current 3008_AUTOMATIC_TRANS_LUBRICATION
- Service 22
DID D61A - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Automatic transmission oil aging sensor 3008_AUTOMATIC_TRANS_OILConfirmed
- Service 22
DID D405 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x00006470 = 25712 → 25,712
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic transmission oil drain 3008_DRAIN_TRANSConfirmed
- Service 22
DID D509 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic transmission output shaft mode, calculated 3008_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE
- Service 22
DID D653 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8128 to 4186112 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Automatic transmission output shaft mode, measured 3008_AUTOMATIC_TRANS_OUTPUT
- Service 22
DID D652 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Automatic transmission overheat indicator request 3008_AUTOMATIC_TRANSConfirmed
- Service 22
DID D510 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Automatic transmission torque request 3008_AUTOMATIC_TRANS_TQConfirmed
- Service 22
DID D508 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
0xFE = 254 → = 408 N·m
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Calculated gear in gearbox 3008_CALC_GEAR_GEARBOXConfirmed
- Service 22
DID D409 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Clutch pedal 3008_CLU_PEDALConfirmed
- Service 22
DID D404 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Clutch pedal position value 3008_CLU_PEDAL_POSConfirmed
- Service 22
DID D469 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 3008_CTRL_CURRENT_P_P
- Service 22
DID D625 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 3008_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P
- Service 22
DID D61E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Control current of electromagnetic valve of change of pressure of torque converter lock-up 3008_CTRL_CURRENT_P
- Service 22
DID D61C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Control current of the electromagnetic valve for changing the gear shift SC2 3008_CTRL_CURRENT
- Service 22
DID D60A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Control current of the electromagnetic valve of change of pressure of clutch C3 3008_CTRL_CURRENT_P_C3Confirmed
- Service 22
DID D614 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x0A = 10 → = 100 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Control current of the electromagnetic valve of change of pressure of clutch C4 3008_CTRL_CURRENT_P_C4
- Service 22
DID D620 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Control current of the solenoid valve for changing the pressure of the clutch C1 3008_CTRL_CURRENT_P_C1Confirmed
- Service 22
DID D610 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x0A = 10 → = 100 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Control current of the solenoid valve for changing the pressure of the clutch C2 3008_CTRL_CURRENT_P_C2Confirmed
- Service 22
DID D612 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x0A = 10 → = 100 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
DC-DC converter temperature 3008_DC_DC_CONV_T
- Service 22
DID D8CE - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Engaged gear 3008_ENGAGED_GEARConfirmed
- Service 22
DID D43D - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Engaged gear 3008_ENGAGED_GEAR_6A9Confirmed
- Service 22
DID D501 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Exhaust gas temperature after upstream catalytic converter 3008_EXH_GAS_T_AFTER_PRE
- Service 22
DID D555 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Exhaust gas temperature before upstream catalytic converter 3008_EXH_GAS_T_BEFORE_PRE
- Service 22
DID D52E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Gear in the process of engaging 3008_GEAR_PROCESSConfirmed
- Service 22
DID D43E - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Gear shift knob under steering wheel 3008_GEAR_SHIFT_KNOBConfirmed
- Service 22
DID D520 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Gear shift lever position displayed on instrument panel 3008_GEAR_SHIFT_LEVER_POS_ONConfirmed
- Service 22
DID D500 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x03 = 3 → 3
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Maximum clutch travel during gear shift 3008_MAX_CLU_TRAVELConfirmed
- Service 22
DID D498 - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Measured current of control of electromagnetic valve of automatic transmission lubrication 3008_MEAS_CURRENT_CTRL
- Service 22
DID D61B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 3008_MEAS_CURRENT_CTRL_P
- Service 22
DID D61D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Measured current of the electromagnetic valve for changing the gear shift SC2 3008_MEAS_CURRENT
- Service 22
DID D60B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 3008_MEAS_CURRENT_P_P
- Service 22
DID D626 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Measured current of the electromagnetic valve of change of pressure of clutch C3 3008_MEAS_CURRENT_P_C3Confirmed
- Service 22
DID D615 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x0A = 10 → = 100 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Measured current of the electromagnetic valve of change of pressure of clutch C4 3008_MEAS_CURRENT_P_C4
- Service 22
DID D621 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Measured current of the solenoid valve for changing the pressure of the clutch C1 3008_MEAS_CURRENT_P_C1Confirmed
- Service 22
DID D611 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x09 = 9 → = 90 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Measured current of the solenoid valve for changing the pressure of the clutch C2 3008_MEAS_CURRENT_P_C2Confirmed
- Service 22
DID D613 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x09 = 9 → = 90 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 3008_MEAS_CURRENT_P
- Service 22
DID D61F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Nitrogen oxide content after catalytic converter, ppm 3008_NOX_CONTENT_AFTER
- Service 22
DID D53D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 3008_NOX_CONTENT_MEAS
- Service 22
DID D545 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 3008_NOX_CONTENT_MEAS_INLET_NOX
- Service 22
DID D576 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 3008_NUM_ENGAGEMENTS_P_P
- Service 22
DID D75D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Number of gear engagements 1 3008_NUM_GEAR_ENGAGEMENTS_1Confirmed
- Service 22
DID D747 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0001EB3A = 125754 → 125,754
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements 2 3008_NUM_GEAR_ENGAGEMENTS_2Confirmed
- Service 22
DID D748 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0004027A = 262778 → 262,778
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements 3 3008_NUM_GEAR_ENGAGEMENTS_3Confirmed
- Service 22
DID D749 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x00046598 = 288152 → 288,152
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements 4 3008_NUM_GEAR_ENGAGEMENTS_4Confirmed
- Service 22
DID D74A - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0003680C = 223244 → 223,244
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements 5 3008_NUM_GEAR_ENGAGEMENTS_5Confirmed
- Service 22
DID D74B - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x00022BAA = 142250 → 142,250
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements 6 3008_NUM_GEAR_ENGAGEMENTS_6Confirmed
- Service 22
DID D74C - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0000C277 = 49783 → 49,783
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements 8 3008_NUM_GEAR_ENGAGEMENTS_8
- Service 22
DID D75C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Number of gear engagements n 3008_NUM_GEAR_ENGAGEMENTS_NConfirmed
- Service 22
DID D74E - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0000F06A = 61546 → 61,546
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of gear engagements right 3008_NUM_GEAR_ENGAGEMENTSConfirmed
- Service 22
DID D74D - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x0000D28E = 53902 → 53,902
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Number of shift solenoid operated automatic transmission lubrication control valve 3008_NUM_SHIFT_SOLENOID_OPERATED
- Service 22
DID D756 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Number of shift solenoid operated SC4 3008_NUM_SHIFT_SOLENOID_OPERATED_SC4
- Service 22
DID D754 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Number of shift solenoid operated SC5 3008_NUM_SHIFT_SOLENOID_OPERATED_SC5
- Service 22
DID D755 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Number of shift solenoid operated torque converter lock-up pressure regulating valve 3008_NUM_SHIFT_SOLENOID_P
- Service 22
DID D757 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Operating mode used by the automatic transmission 3008_OP_MODE_USEDConfirmed
- Service 22
DID D673 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x0D = 13 → 13
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Position of the gearshift lever 3008_POS_GEARSHIFT_LEVERConfirmed
- Service 22
DID D700 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x03 = 3 → 3
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Proportional clutch pedal sensor 3008_PROPORTIONAL_CLU
- Service 22
DID D56E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Reverse gear contactor status 3008_REVERSE_GEARConfirmed
- Service 22
DID D43C - Module
6A8 → 688 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
SC5 shift solenoid control current 3008_SC5_SHIFT_SOLENOID
- Service 22
DID D618 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
SC5 shift solenoid measured current 3008_SC5_SHIFT_SOLENOID_MEAS
- Service 22
DID D619 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Shift solenoid control current SC3 3008_SHIFT_SOLENOID_CTRL
- Service 22
DID D60C - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Shift solenoid control current SC4 3008_SHIFT_SOLENOID_CTRL_CURRENT_SC4
- Service 22
DID D60E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Shift solenoid measured current SC3 3008_SHIFT_SOLENOID_MEAS
- Service 22
DID D60D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Shift solenoid measured current SC4 3008_SHIFT_SOLENOID_MEAS_CURRENT_SC4
- Service 22
DID D60F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Shift-lock control 3008_SHIFT_LOCK_CTRLConfirmed
- Service 22
DID D701 - Module
6A9 → 689 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Start permission from gearbox computer 3008_START_PERMISSIONConfirmed
- Service 22
DID D41A - Module
6A8 → 688 - Every
1 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Torque converter lock-up pressure variation solenoid valve control current 3008_TQ_CONV_LOCK_UP_PConfirmed
- Service 22
DID D604 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x0A = 10 → = 100 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Torque converter lock-up pressure variation solenoid valve control current 3008_TQ_CONV_LOCK_UP_P_VARIATIONConfirmed
- Service 22
DID D605 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
0x09 = 9 → = 90 mA
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Torque converter slip mode, theoretical value 3008_TQ_CONV_SLIP_MODEConfirmed
- Service 22
DID D655 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
0x7F = 127 → = 0 rpm
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Torque converter status 3008_TQ_CONV_STATConfirmed
- Service 22
DID D504 - Module
6A9 → 689 - Every
250 ms - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.
Upstream catalytic converter aging 3008_PRE_CATALYTIC_CONV
- Service 22
DID D559 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Trips
Distance to next oil change 3008_DIST_NEXT_OIL_CHANGE
- Service 22
DID D536 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Distance traveled since the last regeneration 3008_DIST_TRAVELED_SINCE
- Service 22
DID D519 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Odometer 3008_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Odometer 3008_ODO_6A2
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A2 → 682 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Odometer 3008_ODO_6A6
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A6 → 686 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 km
- Unit
- km
In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.
Odometer 3008_ODO_6A9Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID D802 - Module
6A9 → 689 - Every
30 s - Testing for 2008 to 2018, 2020 to 2026
Example reply from a 2019 Peugeot 3008.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x037BA1 = 228257 → 228,257 km
Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.