Peugeot 508

Parameters

The Peugeot 508 has 444 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Accelerator pedal signal 1 voltage 508_ACCEL_PEDAL_SIG_1_V

  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal signal 1 voltage 508_ACCEL_PEDAL_SIG_1_V

  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Accelerator pedal signal 2 voltage 508_ACCEL_PEDAL_SIG_2_V

  • Service 22DID D406
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Approximate position of turbocharger actuator 508_APPROXIMATE_POS

  • Service 22DID D4EC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Battery current 508_BAT_CURRENT

  • Service 22DID D497
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1024
Range
-2097152 to 2097151 A
Unit
A

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Centralized voltage maintenance device temperature limiter state 508_CENTRALIZED_V_T

  • Service 22DID D759
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Computer power supply voltage 508_COMPUTER_POWER_SUP_V

  • Service 22DID D551
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.

Energy accumulator discharge permission state 508_ENERGY_ACCUMULATOR

  • Service 22DID D74F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine control computer supply voltage 508_ENG_CTRL_COMPUTER_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine oil level sensor voltage 508_ENG_OIL_LEVEL_SENS_V

  • Service 22DID D41E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Evaluation of the total resistance of the voltage maintaining device 508_EVALUATION_TOT_RES_V

  • Service 22DID D72D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128040.9703
Range
0 to 0.511
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Glow plug unit supply voltage 508_PREHEATING_V

  • Service 22DID D50E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Minimum battery voltage at startup 508_MIN_BAT_V_STARTUP

  • Service 22DID D4D4
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50.00000112
Range
-655 to 655 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Reversible generator voltage 508_REVERSIBLE_GEN_V

  • Service 22DID D713
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Service battery charge state 508_SERVICE_BAT_CHG_ST

  • Service 22DID D742
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Service battery charge status 508_SERVICE_BAT_CHG_STAT

  • Service 22DID D467
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Service battery temperature 508_SERVICE_BAT_T_6A8

  • Service 22DID D496
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Service battery voltage 508_SERVICE_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D78A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Service battery wear condition 508_SERVICE_BAT_WEAR

  • Service 22DID D741
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Set voltage of energy storage 508_SET_V_ENERGY_STORAGE

  • Service 22DID D734
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Set voltage of storage battery charging 508_SET_V_STORAGE_BAT

  • Service 22DID D766
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Set voltage of the reversible generator 508_SET_V_REVERSIBLE_GEN

  • Service 22DID D712
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val39.9999994+10.60000038
Range
0 to 16.97 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Stop permitted by voltage maintainer computer 508_STOP_PERMITTED_V

  • Service 22DID D749
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Temperature of the electronic power unit of the voltage maintenance device 508_T_ELECTRONIC_POWER_V

  • Service 22DID D730
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Turbocharger control duty cycle 508_TURBOCHARGER_CTRL

  • Service 22DID D48A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 127 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Turbocharger first electronic boost 508_TURBOCHARGER_FIRST

  • Service 22DID D48C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Turbocharger position information 508_TURBOCHARGER_POS

  • Service 22DID D4EA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Turbocharger pressure measured 508_TURBOCHARGER_P_MEAS

  • Service 22DID D4D9
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Turbocharger pressure reference 508_TURBOCHARGER_P

  • Service 22DID D556
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Turbocharger, target position 508_TURBOCHARGER_TGT_POS

  • Service 22DID D47B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Voltage at the terminals of the energy accumulator 508_V_TERMINALS_ENERGY

  • Service 22DID D720
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Voltage maintainer computer request sent 508_V_MAINTAINER_COMPUTER_REQ

  • Service 22DID D748
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Voltage maintainer computer restart permission 508_V_MAINTAINER

  • Service 22DID D747
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Voltage maintainer status 508_V_MAINTAINER_STAT

  • Service 22DID D72C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014 to 2015, 2019. Supported for 2012 to 2013.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2019, 2021.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Anti-lock brake or stability control regulating 508_ABS_EKS_PROCESS_ADJ

  • Service 22DID D474
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Brake circuit pressure 508_BRAKE_CIRCUIT_P

  • Service 22DID D70E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Brake system backup contactor status 508_BRAKE_SYSTEM_BACKUP

  • Service 22DID D463
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Main brake contactor status 508_MAIN_BRAKE_CONTACTOR

  • Service 22DID D513
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Secondary brake contactor status 508_SECONDARY_BRAKE

  • Service 22DID D514
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vacuum present in the brake system 508_VACUUM_PRESENT_BRAKE

  • Service 22DID D700
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2019, 2021.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2019. Supported for 2021.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. Supported for 2021.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2019. Supported for 2021.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Engine

5V power supply state number 1 508_5V_POWER_SUP_ST_1

  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

5V power supply state number 2 508_5V_POWER_SUP_ST_2

  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

5V power supply state number 3 508_5V_POWER_SUP_ST_3

  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

5V power supply state number 4 508_5V_POWER_SUP_ST_4

  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

12V network allowed stop 508_12V_NETWORK_ALLOWED

  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Activation count, brake electromagnetic valve B1 508_NUM_ACTIVATIONS_B1

  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, line pressure control solenoid 508_NUM_LINE_P_CTRL

  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve of brake B2 508_NUM_ACTIVATIONS_B2

  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Actual oil pressure 508_ACT_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Additional heater control 1 508_ADDITIONAL_HEATER_1

  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air conditioning 508_AC

  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air conditioning compressor current 508_AC_COMP_CURRENT

  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air conditioning pressure 508_AC_P

  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air doser first electronic loading 508_AIR_DOSER_FIRST

  • Service 22DID D53B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air flow 508_AIR_FLOW

  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.

Air flow target 508_AIR_FLOW_TGT

  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air metering valve duty cycle 508_AIR_METERING_VLV

  • Service 22DID D461
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air metering valve position 508_AIR_METERING_VLV_POS

  • Service 22DID D54F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air metering valve, target position 508_AIR_METERING_VLV_TGT

  • Service 22DID D460
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Air temperature by air flow meter 508_AIR_T_AIR_FLOW_METER

  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Alternator load value 508_ALTERNATOR_LOAD

  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Ambient air temperature 508_AAT_6A9

  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

ANTI START PROGRAMMING STATUS 508_ANTI_START

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Assessment of thermal aging of the particulate filter 508_ASSESSMENT_THERMAL

  • Service 22DID D532
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25128
Range
0 to 12799 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Atmospheric pressure 508_ATMOSPHERIC_P

  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Automatic restart request from body control module 508_AUTOMATIC_RESTART_REQ_BSI

  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Automatic restart request from engine management computer 508_AUTOMATIC_RESTART

  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Automatic stop allowed by body control module 508_AUTOMATIC_STOP

  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Automatic stop allowed by power steering computer 508_AUTOMATIC_STOP_ALLOWED_POWER_STEER

  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Auxiliary heater 2 control 508_AUXILIARY_HEATER_2

  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Average mileage for the last 10 regenerations 508_AVG_MILEAGE_LAST_10

  • Service 22DID D525
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val16
Range
0 to 4095 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Boost air temperature 508_BOOST_AIR_T

  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Button state 508_BUTTON_ST

  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.

Camshaft/crankshaft position synchronization 508_CAM_CRANK_POS

  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2019. Supported for 2021.

CHANGE REPORT IN PROGRESS 508_CHANGE_REPORT

  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Closed loop soot load assessment of the diesel particulate filter 508_CLOSED_LOOP_SOOT

  • Service 22DID D54B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Combustion engine state 508_ICE_ST

  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2021.

Commanded oil pressure 508_CMD_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019. Supported for 2021.

Commanded wastegate A position WG_A_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Commanded wastegate B position WG_B_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Computer lock 508_COMPUTER_LOCK

  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Computer remote wake-up state 508_COMPUTER_WAKE_UP_ST

  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Computer restarts since memory erase 508_CNT_NUM_RE

  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Computer temperature 508_COMPUTER_T

  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Control current of electromagnetic valve for changing the pressure in the brake system B2 508_CTRL_CURRENT_P_B2

  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 508_CTRL_CURRENT_P_B1

  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Controlled air supply module 508_CONTROLLED_AIR_SUP

  • Service 22DID D4A0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Coolant temperature 508_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Coolant temperature target 508_ECT_TGT

  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Coolant temperature, corrected 508_ECT_CORRECTED

  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Cruise control, RW status 508_CRUISE_CTRL_RW_STAT

  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Cylinder 1 injector flow correction 508_CYL_1_INJ_FLOW_CORR

  • Service 22DID D546
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Cylinder 2 injector flow correction 508_CYL_2_INJ_FLOW_CORR

  • Service 22DID D547
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Cylinder 3 injector flow correction 508_CYL_3_INJ_FLOW_CORR

  • Service 22DID D548
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Cylinder 4 injector flow correction 508_CYL_4_INJ_FLOW_CORR

  • Service 22DID D549
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Date 508_DATE

  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Diesel particulate filter differential pressure sensor signal deviation from reference value 508_DPF_DIFF_P_SENS_SIG

  • Service 22DID D518
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Diesel particulate filter regeneration status 508_DPF_REGEN_STAT

  • Service 22DID D521
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Driver presence 508_DRIVER_PRESENCE

  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Driver, requested torque value 508_DRIVER_REQ_TQ

  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Economy mode off state 508_ECO_MODE_OFF_ST

  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2019.

Electric cooling fan control 508_GMV_ELEC_COOLING_FAN

  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Energy accumulator state transfer 508_ENERGY_ACCUMULATOR_ST

  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Energy accumulator temperature limiter state 508_ENERGY_ACCUMULATOR_T

  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine control module status 508_ENG_CTRL_MODULE_STAT

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine coolant temperature 508_ECT_6A9

  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.

Engine oil dilution protection status 508_ENG_OIL_DILUTION

  • Service 22DID D524
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine operating mode 508_ENG_OP_MODE

  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine restart counter 508_ENG_RESTART_CNT

  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine restart counter by stop and start function 508_ENG_RESTART_CNT_STOP

  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine restart request sent by ESP computer 508_ENG_RESTART_REQ_SENT

  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.

Engine stalls 508_ENG_STALLS

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine start prohibition control, start lock 508_ENG_START

  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine stop time 508_ENG_STOP_TIME

  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine torque 508_ENG_TQ

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Estimated torque of internal friction of the engine 508_ESTIMATED_TQ

  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Evaluation of carbon content in engine oil 508_EVALUATION_CARBON

  • Service 22DID D523
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Evaluation of the degree of dilution of motor oil 508_EVALUATION_DEGREE

  • Service 22DID D51F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Evaluation of the exhaust gas flow using the nox sensor 508_EVALUATION_EXH_GAS

  • Service 22DID D542
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×100
Range
-214748364800 to 214748364700 L
Unit
L

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas flow through the particulate filter 508_EXH_GAS_FLOW_THROUGH

  • Service 22DID D533
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×219.726593
Range
0 to 14399782 L
Unit
L

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas pressure at the outlet of the particulate filter 508_EXH_GAS_P_OUTLET_PF

  • Service 22DID D544
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val999.9999525
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas recirculation high limit electronic loading 508_EGR_HIGH_LIM

  • Service 22DID D553
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas recirculation low limit electronic loading 508_EGR_LOW_LIM

  • Service 22DID D552
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas recirculation valve duty cycle 508_EGR_VLV_CTRL_SIG_RCO

  • Service 22DID D511
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas recirculation valve first electronic loading 508_EGR_VLV_FIRST

  • Service 22DID D53A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas recirculation valve position 508_EGR_VLV_POS

  • Service 22DID D509
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas recirculation valve set position 508_EGR_VLV_SET_POS

  • Service 22DID D510
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Expected generator supplier identifier of the reversible generator 508_EXPECTED_GEN

  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Expected identifier of electronic power circuit of reversible generator generator 508_EXPECTED_IDENTIFIER_ELECTRONIC

  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Expected identifier of reversible generator 508_EXPECTED_IDENTIFIER

  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

FUGITIVE TRIP IN EMERGENCY MODE 508_FUGITIVE_TRIP

  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Generator mode 508_GEN_MODE

  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×75
Range
0 to 19125 rpm
Unit
rpm

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Generator shutdown 508_GEN_SHUTDOWN

  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Glow plug plug set temperature 508_PREHEATING_T

  • Service 22DID D50F
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Glow plug relay status 508_STAT_PRE_POST

  • Service 22DID D50D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Identifier of the electronic power circuit of the reversible generator 508_IDENTIFIER

  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Identifier of the supplier of the reversible generator 508_IDENTIFIER_SUPPLIER

  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Immobilizer code programming status 508_IMMOBILIZER_CODE

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Indicated engine torque 508_INDICATED_ENG_TQ

  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Injector code 1 508_INJ_CODE_1

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 47 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Injector code 2 508_INJ_CODE_2

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 72 to 111 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Injector code 3 508_INJ_CODE_3

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 136 to 175 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Injector code 4 508_INJ_CODE_4

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 200 to 239 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Line pressure solenoid valve control current 508_SLT_LINE_P_VARIATION

  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Lock status 508_LOCK_STAT

  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Long-term regeneration capability 508_LONG_TERM_REGEN

  • Service 22DID D54D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Mass of urea injected for thermal protection of urea injector 508_MASS_UREA_INJECTED

  • Service 22DID D56B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50.00000112
Range
0 to 1310 g
Unit
g

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Maximum allowable torque 508_MAX_ALLOWABLE_TQ

  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 508_MEAS_CURRENT_P_B2

  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 508_MEAS_CURRENT_P_B1

  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured line pressure variation solenoid valve current 508_MEAS_LINE_P

  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mileage remaining before diesel particulate filter replacement 508_MILEAGE_REMAINING

  • Service 22DID D530
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×16
Range
-524288 to 524272 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Mileage since last diesel particulate filter replacement 508_MILEAGE_SINCE_DPF

  • Service 22DID D531
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8
Range
0 to 524280 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Mileage since last oil change 508_MILEAGE_SINCE_OIL

  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Mixture enrichment measured by nox sensor at inlet 508_MIXTURE_ENRICHMENT

  • Service 22DID D571
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Mixture enrichment measured by nox sensor at outlet 508_MIXTURE_ENRICHMENT_MEAS

  • Service 22DID D55B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Movement of controlled air supply module 508_MOVEMENT_CONTROLLED

  • Service 22DID D4EB
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Neutral position sensor status 508_NEUTRAL_POS_SENS

  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nox sensor heating control 508_NOX_SENS_HEATING

  • Service 22DID D554
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nox sensor signal status at the inlet 508_NOX_SENS_SIG_STAT_INLET

  • Service 22DID D572
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nox sensor signal status at the outlet 508_NOX_SENS_SIG_STAT

  • Service 22DID D573
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nox system operating status 508_NOX_SYSTEM_OP_STAT

  • Service 22DID D540
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Number of engine stop information deletion cycles 508_NUM_ENG_STOP

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Oil pressure 508_OIL_P

  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Oil pressure reference value 508_OIL_P_REFERENCE

  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Oil pressure regulation control 508_OIL_P_REGULATION

  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Oil temperature 508_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Open loop soot load assessment of the diesel particulate filter 508_OPEN_LOOP_SOOT_LOAD

  • Service 22DID D54A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1024
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Outside air temperature 508_AAT_6A8

  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Particulate filter differential pressure 508_PF_DIFF_P

  • Service 22DID D520
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Power consumed for heating the pipelines of the urea injection system 508_POWER_CONSUMED

  • Service 22DID D580
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Power spent on heating the urea injection system pipes, percentage ratio 508_POWER_SPENT_ON

  • Service 22DID D53C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val163.8399875
Range
0 to 399 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Powertrain condition 508_POWERTRAIN_COND

  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Preheating relay control 508_PREHEATING_RELAY

  • Service 22DID D50C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Presence of the identifier of the reversible generator 508_PRESENCE_IDENTIFIER

  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Pressure-based injection permission for urea solution 508_P_BASED_INJ

  • Service 22DID D514
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED_WHILE

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Real engine torque 508_REAL_ENG_TQ

  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Regeneration enable 508_REGEN_ENABLE

  • Service 22DID D528
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Remaining urea solution in the urea tank 508_REMAINING_UREA

  • Service 22DID D517
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×125128
Range
0 to 63999
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Remote wake-up circuit status 508_REMOTE_WAKE_UP

  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Remote wake-up state 508_REMOTE_WAKE_UP_ST

  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Request to turn on the engine diagnostic indicator 508_REQ_TURN_ON_ENG

  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Requested value controlled thermostat 508_REQ_CONTROLLED

  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Restart request sent by power steering computer 508_RESTART_REQ_SENT

  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Restart request sent by suspension computer 508_RESTART_REQ_SENT_SUSPENSION

  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Return to engine start and restart control by starter 508_RETURN_ENG_START

  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Return to starter engine restart control 508_RETURN_STARTER_ENG

  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Reverse generator status 508_REVERSE_GEN_STAT

  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Reversible generator torque 508_REVERSIBLE_GEN_TQ

  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Service network related engine restart request 508_SERVICE_NETWORK

  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021.

Short-term regeneration capability 508_SHORT_TERM_REGEN

  • Service 22DID D54C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Soot clogging level of diesel particulate filter 508_SOOT_CLOGGING_LEVEL

  • Service 22DID D52F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10.24
Range
0 to 6399 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Specified volume of injected urea solution 508_SPEC_VOLUME_INJECTED

  • Service 22DID D550
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Sport mode contactor state 508_SPORT_MODE_CONTACTOR

  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Start inhibit control, wired 508_START_INHIBIT_CTRL

  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Start or restart inhibition transmitted by engine management computer 508_START_OR_RESTART

  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Start prohibition 508_START_PROHIBITION

  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Starter activation counter 508_STARTER_ACTIVATION

  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Starter control interface unit operating status 508_STARTER_CTRL

  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Starter duty cycle 508_STARTER_DUTY

  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Starter engagement status 508_STARTER_ENGAGEMENT

  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

State lock/unlock control unit 508_ST_LOCK_UNLOCK_CTRL

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Status of internal ignition motor 508_STAT_INTERNAL_IGN

  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Status of the energy accumulator 508_STAT_ENERGY

  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Stop allowed by ESP computer 508_STOP_ALLOWED_ESP

  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Stop and start function state 508_STOP_START_FUNCTION

  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Stop and start switch 508_STOP_START_SWITCH

  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Stop permitted by suspension computer 508_STOP_PERMITTED

  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Temperature of the energy accumulator 508_T_ENERGY_ACCUMULATOR

  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Temperature of the urea solution in the urea tank 508_T_UREA_SOLUTION_UREA

  • Service 22DID D56D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

The composition of the mixture is calculated by the oxygen sensor 508_COMPOSITION_MIXTURE

  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2021.

Torque corresponding to driver requirement 508_TQ_CORRESPONDING

  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Torque supplied or taken by generator 508_TQ_SUPPLIED_OR_TAKEN

  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE

  • Service 22DID D526
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 g
Unit
g

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE_ACCUMULATED_DPF

  • Service 22DID D527
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047 g
Unit
g

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Total mileage 508_ODO_6A8

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Towing device configured 508_CAN_VEH_BE_EQUIPPED

  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Traction or stability control regulating 508_ASR_OR_ESP_SYSTEM

  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Transmission fluid temperature 508_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2019.

Urea mass fraction 508_UREA_MASS_FRACTION

  • Service 22DID D58C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Urea solution injected amount 508_UREA_SOLUTION

  • Service 22DID D568
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Urea solution injection permission based on temperature value 508_UREA_SOLUTION_INJ_ON_T

  • Service 22DID D515
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Urea solution pressure 508_UREA_SOLUTION_P

  • Service 22DID D53E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Urea solution type in urea tank 508_UREA_SOLUTION_TYPE

  • Service 22DID D58D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Urea tank heating current 508_UREA_TANK_HEATING

  • Service 22DID D581
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Urea tank heating current, percentage 508_UREA_TANK_HEATING_CURRENT

  • Service 22DID D51E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val163.8399875
Range
0 to 399 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Vacuum circuit vacuum 508_VACUUM_CIRCUIT

  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Value during generator load smooth increase 508_DURING_GEN_LOAD

  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Vehicle hour meter 508_VEH_HOUR_METER

  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle mileage remaining before filling the tank with urea solution 508_VEH_MILEAGE

  • Service 22DID D513
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Vehicle mileage since the last oil change under severe vehicle operating conditions 508_VEH_MILEAGE_SINCE

  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Volume of urea solution measured in urea tank 508_VOLUME_UREA_SOLUTION

  • Service 22DID D558
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 L
Unit
L

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Wastegate A position WG_A_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Wastegate B position WG_B_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Water in diesel 508_WATER_DIESEL

  • Service 22DID D52C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Winter mode switch state 508_WINTER_MODE_SWITCH

  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Internal

Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 kPa
Unit
kPa

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2014, 2021. Supported for 2012 to 2013, 2015, 2019.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2014. Supported for 2012 to 2013, 2015.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2014, 2021. Supported for 2012 to 2013, 2015, 2019.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2014. Supported for 2012 to 2013, 2015.

Fuel

Amount of fuel additive remaining in the additive tank 508_AMOUNT_FUEL_ADDITIVE

  • Service 22DID D56C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Calculated fuel injection amount 508_CALC_FUEL_INJ_AMOUNT

  • Service 22DID D563
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Desired high pressure common rail fuel pressure 508_DES_HIGH_P_COMMON_P

  • Service 22DID D445
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2021.

First fuel additive injection state 508_FIRST_FUEL_ADDITIVE

  • Service 22DID D56F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Fuel pressure 508_FUEL_P

  • Service 22DID D41F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val999.9999525
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Fuel temperature 508_FUEL_T

  • Service 22DID D42A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

High fuel pressure measured 508_HIGH_FUEL_P_MEAS

  • Service 22DID D446
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Injection angle of the high-pressure fuel pump 508_INJ_ANG_HIGH_P_FUEL

  • Service 22DID D588
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Low pressure fuel pump actuator duty cycle 508_LOW_P_FUEL_PMP

  • Service 22DID D472
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Low pressure fuel pump status 508_LOW_P_FUEL_PMP_STAT

  • Service 22DID D4ED
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Minimum fuel level 508_MIN_FLI

  • Service 22DID D56A
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Movement

Accelerator pedal position 508_ACCEL_PEDAL_POS

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×39100
Range
0 to 99.45 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Accelerator pedal position 508_ACCEL_PEDAL_POS_6A9

  • Service 22DID D505
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Accelerator pedal position, recalculated 508_ACCEL_PEDAL_POS_RECALCULATED

  • Service 22DID D407
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Accelerator pedal position, track 1 508_ACCEL_PEDAL_POS_1

  • Service 22DID D491
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Accelerator pedal position, track 2 508_ACCEL_PEDAL_POS_2

  • Service 22DID D492
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Clutch release state at stop, creep speed reduction 508_CLU_RELEASE_ST_STOP

  • Service 22DID D672
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Crankshaft speed 508_CRANK_SPD

  • Service 22DID D462
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 rpm
Unit
rpm

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Crankshaft speed determined by camshaft sensor 508_CRANK_SPD_DETERMINED

  • Service 22DID D499
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Cruise control set speed 508_CRUISE_CTRL_SET_SPD

  • Service 22DID D475
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine RPM 508_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID D400
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engine RPM 508_RPM_6A9

Pelican can show this parameter as the engine speed.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Input shaft speed 508_INPUT_SHFT_SPD

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Set speed of electric cooling fan 508_SET_SPD_ELEC_COOLING

  • Service 22DID D4AA
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

STATUS COMMANDS REGULATION OR LIMITATION SPEED 508_STAT_COMMANDS

  • Service 22DID D704
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter slip speed, measured 508_TQ_CONV_SLIP_SPD

  • Service 22DID D654
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle speed 508_VSS

Pelican can show this parameter as the speed.

  • Service 21PID C8
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle speed 508_VSS_6A8

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 km/h
Unit
km/h

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Vehicle speed 508_VSS_6A9

Pelican can show this parameter as the speed.

  • Service 22DID D711
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2014 to 2015, 2019, 2021. Supported for 2012 to 2013.

Vehicle speed limiter set speed 508_VSS_LIMITER_SET_SPD

  • Service 22DID D476
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Vehicle speed limiter status, LW 508_VSS_LIMITER_STAT_LW

  • Service 22DID D4C0
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.

Tires

Average front wheel speed 508_AVG_FRONT_WHL_SPD

  • Service 22DID D530
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val25.00000056
Range
0 to 2621 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Average speed front wheels 508_AVG_SPD_FRONT_WHEELS

  • Service 22DID D533
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Counter of occurrence of enhanced resonance of the twin flywheel of the engine 508_CNT_OCCURRENCE

  • Service 22DID D4E4
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Counter of occurrence of resonance of the twin flywheel of the engine 508_CNT_OCCURRENCE_RESONANCE

  • Service 22DID D4E5
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Rear left wheel speed 508_RL_WHL_SPD

  • Service 22DID D531
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Rear right wheel speed 508_RR_WHL_SPD

  • Service 22DID D532
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Transmission

Activation count, additional oil pump, ATN8 gearbox 508_NUM_ADDITIONAL_OIL

  • Service 22DID D750
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch electromagnetic valve C2 508_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2

  • Service 22DID D743
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch electromagnetic valve C3 508_NUM_ACTIVATIONS_CLU_C3

  • Service 22DID D744
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch protection C1 508_NUM_ACTIVATIONS_CLU_C1

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch protection C2 508_NUM_ACTIVATIONS_CLU_C2

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, gear 7 508_NUM_ACTIVATIONS_GEAR_7

  • Service 22DID D75B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, shift solenoid SC2 508_NUM_SHIFT_SOLENOID

  • Service 22DID D752
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, shift solenoid SC3 508_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3

  • Service 22DID D753
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 508_NUM_ACTIVATIONS_P

  • Service 22DID D758
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve of clutch C4 508_NUM_ACTIVATIONS_C4

  • Service 22DID D759
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve of the clutch C1 508_NUM_ACTIVATIONS_C1

  • Service 22DID D742
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, torque converter lockup electromagnetic valve 508_NUM_ACTIVATIONS_TQ

  • Service 22DID D746
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation of additional oil pump, ATN8 gearbox 508_ACTIVATION

  • Service 22DID D616
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Additional oil pump control status, atn8 transmission 508_ADDITIONAL_OIL_PMP

  • Service 22DID D617
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic restart request from transmission computer 508_AUTOMATIC_RESTART_REQ

  • Service 22DID D70B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Automatic stop allowed by gearbox computer 508_AUTOMATIC_STOP_ALLOWED

  • Service 22DID D704
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Automatic transmission fluid temperature 508_AUTOMATIC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D550
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission in emergency mode 508_AUTOMATIC_TRANS_EMERGENCY

  • Service 22DID D670
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission in park position 508_AUTOMATIC_TRANS_PARK

  • Service 22DID D70B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission input shaft mode, calculated 508_AUTOMATIC_TRANS_INPUT_SHFT_MODE

  • Service 22DID D651
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission input shaft mode, measured 508_AUTOMATIC_TRANS_INPUT_SHFT

  • Service 22DID D650
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission lubrication solenoid control current 508_AUTOMATIC_TRANS_LUBRICATION

  • Service 22DID D61A
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission oil aging sensor 508_AUTOMATIC_TRANS_OIL

  • Service 22DID D405
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission oil drain 508_DRAIN_TRANS

  • Service 22DID D509
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission output shaft mode, calculated 508_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE

  • Service 22DID D653
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64−8128
Range
-8128 to 4186112 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission output shaft mode, measured 508_AUTOMATIC_TRANS_OUTPUT

  • Service 22DID D652
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission overheat indicator request 508_AUTOMATIC_TRANS

  • Service 22DID D510
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission torque request 508_AUTOMATIC_TRANS_TQ

  • Service 22DID D508
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated gear in gearbox 508_CALC_GEAR_GEARBOX

  • Service 22DID D409
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Calculated nox content at the inlet of the nox catalytic converter 508_CALC_NOX_CONTENT

  • Service 22DID D53F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1024
Range
0 to 4194303
Unit
Raw value

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Clutch pedal 508_CLU_PEDAL

  • Service 22DID D404
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Clutch pedal position value 508_CLU_PEDAL_POS

  • Service 22DID D469
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 508_CTRL_CURRENT_P_P

  • Service 22DID D625
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 508_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P

  • Service 22DID D61E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of electromagnetic valve of change of pressure of torque converter lock-up 508_CTRL_CURRENT_P

  • Service 22DID D61C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve for changing the gear shift SC2 508_CTRL_CURRENT

  • Service 22DID D60A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve of change of pressure of clutch C3 508_CTRL_CURRENT_P_C3

  • Service 22DID D614
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve of change of pressure of clutch C4 508_CTRL_CURRENT_P_C4

  • Service 22DID D620
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the solenoid valve for changing the pressure of the clutch C1 508_CTRL_CURRENT_P_C1

  • Service 22DID D610
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the solenoid valve for changing the pressure of the clutch C2 508_CTRL_CURRENT_P_C2

  • Service 22DID D612
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engaged gear 508_ENGAGED_GEAR

  • Service 22DID D43D
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Engaged gear 508_ENGAGED_GEAR_6A9

  • Service 22DID D501
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Evaluation of the thermal aging of the NOx catalytic converter 508_EVALUATION_THERMAL

  • Service 22DID D541
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val655.35995
Range
0 to 99.99 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas temperature after upstream catalytic converter 508_EXH_GAS_T_AFTER_PRE

  • Service 22DID D555
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Exhaust gas temperature before upstream catalytic converter 508_EXH_GAS_T_BEFORE_PRE

  • Service 22DID D52E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Gear in the process of engaging 508_GEAR_PROCESS

  • Service 22DID D43E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Gear shift knob under steering wheel 508_GEAR_SHIFT_KNOB

  • Service 22DID D520
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Gear shift lever position displayed on instrument panel 508_GEAR_SHIFT_LEVER_POS_ON

  • Service 22DID D500
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Maximum clutch travel during gear shift 508_MAX_CLU_TRAVEL

  • Service 22DID D498
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Measured current of control of electromagnetic valve of automatic transmission lubrication 508_MEAS_CURRENT_CTRL

  • Service 22DID D61B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 508_MEAS_CURRENT_CTRL_P

  • Service 22DID D61D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve for changing the gear shift SC2 508_MEAS_CURRENT

  • Service 22DID D60B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 508_MEAS_CURRENT_P_P

  • Service 22DID D626
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve of change of pressure of clutch C3 508_MEAS_CURRENT_P_C3

  • Service 22DID D615
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve of change of pressure of clutch C4 508_MEAS_CURRENT_P_C4

  • Service 22DID D621
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the solenoid valve for changing the pressure of the clutch C1 508_MEAS_CURRENT_P_C1

  • Service 22DID D611
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the solenoid valve for changing the pressure of the clutch C2 508_MEAS_CURRENT_P_C2

  • Service 22DID D613
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 508_MEAS_CURRENT_P

  • Service 22DID D61F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nitrogen oxide content after catalytic converter, ppm 508_NOX_CONTENT_AFTER

  • Service 22DID D53D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 508_NOX_CONTENT_MEAS

  • Service 22DID D545
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 508_NOX_CONTENT_MEAS_INLET_NOX

  • Service 22DID D576
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Nox catalytic converter urea content 508_NOX_CATALYTIC_CONV

  • Service 22DID D55D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val999.9999525
Range
0 to 65.53 g
Unit
g

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 508_NUM_ENGAGEMENTS_P_P

  • Service 22DID D75D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 1 508_NUM_GEAR_ENGAGEMENTS_1

  • Service 22DID D747
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 2 508_NUM_GEAR_ENGAGEMENTS_2

  • Service 22DID D748
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 3 508_NUM_GEAR_ENGAGEMENTS_3

  • Service 22DID D749
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 4 508_NUM_GEAR_ENGAGEMENTS_4

  • Service 22DID D74A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 5 508_NUM_GEAR_ENGAGEMENTS_5

  • Service 22DID D74B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 6 508_NUM_GEAR_ENGAGEMENTS_6

  • Service 22DID D74C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 8 508_NUM_GEAR_ENGAGEMENTS_8

  • Service 22DID D75C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements n 508_NUM_GEAR_ENGAGEMENTS_N

  • Service 22DID D74E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements right 508_NUM_GEAR_ENGAGEMENTS

  • Service 22DID D74D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated automatic transmission lubrication control valve 508_NUM_SHIFT_SOLENOID_OPERATED

  • Service 22DID D756
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated SC4 508_NUM_SHIFT_SOLENOID_OPERATED_SC4

  • Service 22DID D754
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated SC5 508_NUM_SHIFT_SOLENOID_OPERATED_SC5

  • Service 22DID D755
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated torque converter lock-up pressure regulating valve 508_NUM_SHIFT_SOLENOID_P

  • Service 22DID D757
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Operating mode used by the automatic transmission 508_OP_MODE_USED

  • Service 22DID D673
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Position of the gearshift lever 508_POS_GEARSHIFT_LEVER

  • Service 22DID D700
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Proportional clutch pedal sensor 508_PROPORTIONAL_CLU

  • Service 22DID D56E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Reverse gear contactor status 508_REVERSE_GEAR

  • Service 22DID D43C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

SC5 shift solenoid control current 508_SC5_SHIFT_SOLENOID

  • Service 22DID D618
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

SC5 shift solenoid measured current 508_SC5_SHIFT_SOLENOID_MEAS

  • Service 22DID D619
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid control current SC3 508_SHIFT_SOLENOID_CTRL

  • Service 22DID D60C
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid control current SC4 508_SHIFT_SOLENOID_CTRL_CURRENT_SC4

  • Service 22DID D60E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid measured current SC3 508_SHIFT_SOLENOID_MEAS

  • Service 22DID D60D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid measured current SC4 508_SHIFT_SOLENOID_MEAS_CURRENT_SC4

  • Service 22DID D60F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift-lock control 508_SHIFT_LOCK_CTRL

  • Service 22DID D701
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Start permission from gearbox computer 508_START_PERMISSION

  • Service 22DID D41A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Temperature of the nox catalytic converter 508_T_NOX_CATALYTIC_CONV

  • Service 22DID D543
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °C
Unit
°C

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Torque converter lock-up pressure variation solenoid valve control current 508_TQ_CONV_LOCK_UP_P

  • Service 22DID D604
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter lock-up pressure variation solenoid valve control current 508_TQ_CONV_LOCK_UP_P_VARIATION

  • Service 22DID D605
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter slip mode, theoretical value 508_TQ_CONV_SLIP_MODE

  • Service 22DID D655
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter status 508_TQ_CONV_STAT

  • Service 22DID D504
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Upstream catalytic converter aging 508_PRE_CATALYTIC_CONV

  • Service 22DID D559
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Trips

Distance to next oil change 508_DIST_NEXT_OIL_CHANGE

  • Service 22DID D536
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Distance traveled since the last regeneration 508_DIST_TRAVELED_SINCE

  • Service 22DID D519
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val16
Range
0 to 4095 km
Unit
km

In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.

Odometer 508_ODO_6A9

Pelican can show this parameter as the odometer.

  • Service 22DID D802
  • Module6A9 → 689
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.