Parameters
The Toyota Veloz has 347 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
+BM voltage VELOZ_BM_V
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2021 to 2026.
Battery current VELOZ_BAT_CURRENT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2021 to 2026.
Battery temperature VELOZ_BAT_T
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2021 to 2026.
Battery voltage VELOZ_BAT_V
- Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2021 to 2026.
Battery voltage VELOZ_BATTERY_VOLTAGE_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2021 to 2026.
Charge contactor current VELOZ_SCC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2021 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2024.
Main connector solenoid current VELOZ_SMC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2021 to 2026.
Main relay a, solenoid current VELOZ_SLA_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2021 to 2026.
Main relay r solenoid current VELOZ_SLR_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2021 to 2026.
Output speed sensor voltage VELOZ_NOUT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2021 to 2026.
Regenerative braking cooperation VELOZ_REGEN_COOPERATION
- Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Regenerative operation VELOZ_FR_REGEN_OPERATION
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Regenerative request VELOZ_FR_REGEN_REQUEST
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Relay control solenoid current VELOZ_SRC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2021 to 2026.
Service contactor solenoid current VELOZ_SSC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2021 to 2026.
Turbine speed sensor voltage VELOZ_NT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2021 to 2026.
Brakes
Parking brake actuator status VELOZ_EPB
- Service 22
DID 1045 - Module
7B0 → 7B8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | APPLIED | Applied |
In testing for 2021 to 2026.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024.
Communication with air conditioner VELOZ_COMM_WITH_AIR_CONDITIONER
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Communication with HV VELOZ_COMMUNICATION_WITH_HV
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Communication with valvematic VELOZ_COMM_WITH_VALVEMATIC_COMM
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2024.
Control
A/C compressor VELOZ_A_C_COMPRESSOR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Accelerator sensor voltage, 1 VELOZ_ACCEL_SENS_1_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Accelerator sensor voltage, 2 VELOZ_ACCEL_SENS_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Anti-lock brake warning light VELOZ_ABS_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Brake pedal stroke VELOZ_BRAKE_STROKE
- Service 22
DID 104C - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mm
- Unit
- mm
In testing for 2021 to 2026.
Brake warning light VELOZ_BRAKE_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Buzzer VELOZ_BUZZER
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Communication with brake VELOZ_COMMUNICATION_WITH_BRAKE
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Cruise control live brake cancel VELOZ_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Electrical load signal 1 VELOZ_ELECTRICAL_LOAD_SIGNAL_1
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Electrical load signal 2 VELOZ_ELECTRICAL_LOAD_SIGNAL_2
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Electronically controlled brake warning light VELOZ_ECB_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Ignition trigger count VELOZ_IGNITION_TRIG_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Key remind sound VELOZ_KEY_REMIND_SOUND
- Service 21
PID A1 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Main idle VELOZ_MAIN_IDLE_SW
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Neutral position VELOZ_NEUTRAL_POSITION_SW_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 53 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Parking brake VELOZ_PARKING_BRAKE_SW
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Pattern switch VELOZ_PATTERN_SWITCH_PWR_M
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 42 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Power steering VELOZ_POWER_STEERING_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Reservoir warning VELOZ_RESERVOIR_WARNING_SW
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Shift SW status, drive VELOZ_SHIFT_SW_STATUS_D_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Shift SW status, neutral VELOZ_SHIFT_SW_STATUS_N_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Shift SW status, parking VELOZ_SHIFT_SW_STATUS_P_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Shift SW status, reverse VELOZ_SHIFT_SW_STATUS_R_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Slip indicator light VELOZ_SLIP_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Sports mode selection VELOZ_SPORTS_MODE_SELECTION_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Sports shift down VELOZ_SPORTS_SHIFT_DOWN_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Sports shift up VELOZ_SPORTS_SHIFT_UP_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Starter control VELOZ_STARTER_CONTROL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Starter signal VELOZ_STARTER_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Steering wheel angle VELOZ_STEER_ANGLEConfirmed
Positive = counter-clockwise, negative = clockwise.
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
0x7FB5 = 32693 → = -7.5 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
TC VELOZ_TC_TERMINAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Traction control, brake status VELOZ_TRC_TRAC__BRAKE_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Details
Inspection mode VELOZ_INSPECTION_MODE
- Service 21
PID A6 - Module
7B0 → 7B8 - Every
60 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
DTCs
2nd air monitor available? VELOZ_2ND_AIR_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
2nd air monitor incomplete? VELOZ_2ND_AIR_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
A/C monitor available? VELOZ_A_C_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
A/C monitor incomplete? VELOZ_A_C_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Catalyst monitor available? VELOZ_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Catalyst monitor incomplete? VELOZ_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Complete parts monitor available? VELOZ_COMPLETE_PARTS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024.
EGR/VVT monitor available? VELOZ_EGR_VVT_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
EGR/VVT monitor incomplete? VELOZ_EGR_VVT_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2024.
EVAP monitor available? VELOZ_EVAP_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
EVAP monitor_icmpl VELOZ_EVAP_MONITOR_ICMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Fuel system monitor available? VELOZ_FUEL_SYSTEM_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Heated catalyst monitor available? VELOZ_HEATED_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Heated catalyst monitor incomplete? VELOZ_HEATED_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2024.
MIL VELOZ_MIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
MIL ON run distance VELOZ_MILON_RUN_DISTANCE
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2021 to 2026.
Misfire monitor available? VELOZ_MISFIRE_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2024.
Number of emission DTC VELOZ_NUMBER_OF_EMISSION_DTC
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2021 to 2026.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2024.
O2S heater monitor available? VELOZ_O2S_A_FS_HEATER_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
O2S heater monitor incomplete? VELOZ_O2S_A_FS_HEATER_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
O2S monitor available? VELOZ_O2S_A_FS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
O2S monitor incomplete? VELOZ_O2S_A_FS_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Running time from MIL ON VELOZ_RUNNING_TIME_FROM_MIL_ON
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2021 to 2026.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2024.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024.
Engine
A/F heater duty bank 1 sensor 1 VELOZ_F_HEATER_DUTY_B1S1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2021 to 2026.
A/F test results 1, incomplete VELOZ_F_TEST_RESULTS_1
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Accessory relay on VELOZ_ACC_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Accumulator open VELOZ_ACCUMULATOR_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Acoustic control induction system vacuum switching valve on VELOZ_ACIS_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Actual engine torque VELOZ_ACT_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Actuator power supply on VELOZ_ACTUATOR_POWER_SUP_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 146 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Air conditioning compressor VELOZ_AC_COMP
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Air-fuel equivalence ratio, bank 1 sensor 1 VELOZ_AF_LAMBDA_B1S1
Pelican can show this parameter as the O2 lambda.
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2021 to 2026.
Air-fuel sensor current, bank 1 sensor 1 VELOZ_AFS_I_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.99 mA
- Unit
- mA
In testing for 2021 to 2026.
Air-fuel sensor voltage, bank 1 sensor 1 VELOZ_AFS_V_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99 V
- Unit
- V
In testing for 2021 to 2026.
Alt voltage - active test VELOZ_ALT_VOL_ACTIVE_TEST
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2021 to 2026.
Alt voltage - non active test VELOZ_ALT_VOL_NON_ACTIVE
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2021 to 2026.
Alternator output duty VELOZ_ALTERNATOR_OUTPUT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2021 to 2026.
Atmospheric pressure VELOZ_ATMOSPHERE_PRESSURE
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Calculated load VELOZ_CALCULATED_LOAD_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Catalyst temperature, bank 1 sensor 1 VELOZ_CAT_T_B1S1
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2021 to 2026.
Catalyst temperature, bank 1 sensor 2 VELOZ_CAT_T_B1S2
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2021 to 2026.
Catalyst temperature, bank 1 sensor 2, variant 2 VELOZ_CAT_T_B1S2_V2
- Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2021 to 2026.
Check mode on VELOZ_CHECK_MODE_ON
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Closed throttle position switch on VELOZ_CLOSED_THROTTLE_POS_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Codes, include history VELOZ_CODES_INCLUDE
- Service 21
PID E1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Continuously variable transmission learning complete VELOZ_CVT_LEARNED
- Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2021 to 2026.
Continuously variable transmission oil pressure VELOZ_CVT_OIL_P
- Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Coolant temperature VELOZ_COOLANT_TEMP_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Cruise control on VELOZ_CRUISE_CTRL_ON
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Cylinder number VELOZ_CYLINDER_NUMBER
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Destination VELOZ_DESTINATION
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Dist battery cable disconnect VELOZ_DIST_BATT_CABLE
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2021 to 2026.
Electric fan motor on VELOZ_ELEC_FAN_MOTOR_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Engine coolant temperature VELOZ_ECT_7C0
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 23 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine independent VELOZ_ENG_INDEPENDENT
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Engine independent control VELOZ_ENG_INDEPENDENT_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Engine oil temperature VELOZ_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x58 = 88 → = 48 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2024.
Engine run time VELOZ_ENGINE_RUN_TIME
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2021 to 2026.
Engine run time, up to 255 sec. only VELOZ_ENG_RUN_TIME_UP_255
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2021 to 2026.
Engine speed VELOZ_ENGINE_SPEED_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Engine stall control FB flow VELOZ_ENG_STALL_CTRL_FB
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 2021 to 2026.
Evaporative purge duty VELOZ_EVAP_PURGE_DUTY_7E0
- Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Evaporative purge flow VELOZ_EVAP_PURGE_FLOW
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.99 %
- Unit
- %
In testing for 2021 to 2026.
Evaporative purge vacuum switching valve on VELOZ_EVAP_PURGE_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Exhaust gas recirculation step position VELOZ_EGR_STEP_POSITION
- Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Exhaust gas recirculation temperature VELOZ_EGR_T
- Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 159 °C
- Unit
- °C
In testing for 2021 to 2026.
Exhaust gas recirculation valve step VELOZ_EGR_STEP
- Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Fuel cut for engine stop request VELOZ_F_C_ENG_STOP_REQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Fuel cut TAU on VELOZ_FC_TAU_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
G sensor calibration, complete VELOZ_G_SENS_CALIBRATION
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
G sensor learning value VELOZ_G_SENS_LEARNING
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2021 to 2026.
Hydraulic valve, communication open VELOZ_HV_COMM_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Idle control VELOZ_IDLE_CTRL
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Idle spark advance control 1 VELOZ_IDLE_SPARK_ADVN_CTRL_1
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2021 to 2026.
Idle spark advance control 2 VELOZ_IDLE_SPARK_ADVN_CTRL_2
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2021 to 2026.
Idle spark advance control 3 VELOZ_IDLE_SPARK_ADVN_CTRL_3
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2021 to 2026.
Idle spark advance control 4 VELOZ_IDLE_SPARK_ADVN_CTRL_4
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2021 to 2026.
Idle speed control learning VELOZ_IDLE_SPD_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Idle speed control learning value, l/s VELOZ_IDLE_SPD_CTRL_L_S
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 2021 to 2026.
IG OFF elapsed time VELOZ_IG_OFF_ELAPSED_TIME
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 min
- Unit
- min
In testing for 2021 to 2026.
Ignition advance VELOZ_SPARKADV_21
- Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2021 to 2026.
Ignition timing advance VELOZ_IGN_ADVANCE
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2021 to 2026.
Immobilizer communication on VELOZ_IMMOBILIZER_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Initial engine coolant temperature VELOZ_INITIAL_ECT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.3
- Unit
- Number
In testing for 2021 to 2026.
Initial intake air temperature VELOZ_INITIAL_IAT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2021 to 2026.
Injection duration for cylinder 1 VELOZ_INJ_DUR_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2021 to 2026.
Injection volume per 10 injections, cylinder 1 VELOZ_INJ_VOL_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.002 L
- Unit
- L
In testing for 2021 to 2026.
Injector pulse width VELOZ_INJ_PW
- Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 2021 to 2026.
Injector pulse width VELOZ_INJ_WIDTH
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2021 to 2026.
Input shaft speed VELOZ_SPD_NIN
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Intake air temperature VELOZ_IAT_21
- Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Intake air temperature VELOZ_INTAKE_AIR_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Judge time engine ignition VELOZ_JUDGE_TIME_ENG_IGN
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2021 to 2026.
Judge time engine output VELOZ_JUDGE_TIME_ENG
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2021 to 2026.
Knock adjust VELOZ_KNOCK_ADJUST
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2021 to 2026.
Knock adjust VELOZ_KNOCK_ADJUST_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2021 to 2026.
Knock correct learn value VELOZ_KNOCK_CORRECT_LEARN
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023 °
- Unit
- °
In testing for 2021 to 2026.
Knock feedback VELOZ_KNOCK_FEEDBACK
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2021 to 2026.
Knock feedback VELOZ_KNOCK_FEEDBACK_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2021 to 2026.
Long term fuel trim, bank 1 VELOZ_LONG_FT_B1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2021 to 2026.
Long term fuel trim, bank 2 VELOZ_LONG_FT_B2
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2021 to 2026.
Long-term fuel trim, bank 1 VELOZ_LTFT1_21
- Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.15 %
- Unit
- %
In testing for 2021 to 2026.
Manifold absolute pressure VELOZ_MAP_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Mass air flow VELOZ_MAF_21
- Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 2021 to 2026.
Mass air flow VELOZ_MAF_7E0
Pelican can show this parameter as the mass air flow.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2021 to 2026.
Master cylinder open VELOZ_MASTER_CYLINDER_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Misfire RPM VELOZ_MISFIRE_RPM_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Misfire test result, incomplete VELOZ_MIS_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Model year VELOZ_MODEL_YEAR
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 1900 to 2155
- Unit
- Number
In testing for 2021 to 2026.
O2 heater b1s2_active VELOZ_O2_HEATER_B1S2
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
O2 heater current val bank 1 sensor 2 VELOZ_O2_HEATER_CURR_VAL
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 A
- Unit
- A
In testing for 2021 to 2026.
Open side malfunction on VELOZ_OPEN_SIDE_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 145 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Output shaft speed VELOZ_SPD_NOUT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2021 to 2026.
OXS1, A/FS2 test result, incomplete VELOZ_OXS1_FS2_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Oxygen sensor voltage, bank 1 sensor 1 VELOZ_O2S11_V
- Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.27 V
- Unit
- V
In testing for 2021 to 2026.
Oxygen sensor voltage, bank 1 sensor 2 VELOZ_O2S_B1S2
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
In testing for 2021 to 2026.
Purge cut vacuum switching valve duty VELOZ_PURGE_CUT_VSV_DUTY
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2021 to 2026.
Racing operation VELOZ_RACING_OPERATION
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Request engine run time VELOZ_REQ_ENG_RUN_TIME
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2021 to 2026.
Request warm-up VELOZ_REQ_WARM_UP
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Requested engine torque VELOZ_REQ_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383
- Unit
- Number
In testing for 2021 to 2026.
Short term fuel trim, bank 1 VELOZ_SHORT_FT_B1
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2021 to 2026.
Short term fuel trim, bank 2 VELOZ_SHORT_FT_B2
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2021 to 2026.
Starter relay on VELOZ_STARTER_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Stroke open VELOZ_STROKE_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
System guard on VELOZ_SYSTEM_GUARD_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 144 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Throttle fully close learn VELOZ_THROTTLE_FULLY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle idle position on VELOZ_THROTTLE_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 149 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Throttle motor current VELOZ_THROTTLE_MOTOR
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.9 A
- Unit
- A
In testing for 2021 to 2026.
Throttle motor duty VELOZ_THROTTLE_MOTOR_DUTY
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Throttle motor duty, close VELOZ_THROTTLE_MOTOR_DUTY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2021 to 2026.
Throttle motor duty, open VELOZ_THROTTLE_MOTOR_DUTY_OPEN
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2021 to 2026.
Throttle position VELOZ_THROTTLE_21
- Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Throttle position command VELOZ_THROTTLE_POS_COMMAND
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle position, number 1 VELOZ_THROTTLE_POS_NUMBER_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle position, number 2 VELOZ_THROTTLE_POS_NUMBER_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle require position VELOZ_THROTTLE_REQUIRE_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle sensor open position 1 VELOZ_THROTTLE_SENS_OPEN_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle sensor open position 2 VELOZ_THROTTLE_SENS_OPEN_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Throttle sensor position VELOZ_THROTTLE_SENSOR_POSITION
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Throttle sensor voltage, 1 VELOZ_THROTTLE_SENSOR_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Throttle sensor voltage, 2 VELOZ_THROTTLE_SENSOR_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Time since DTCs cleared VELOZ_TIME_SINCE_DTC_CLEARED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2021 to 2026.
Total fuel trim, bank 1 VELOZ_TOT_FT_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 49.6 %
- Unit
- %
In testing for 2021 to 2026.
Transmission output shaft speed VELOZ_TRANS_OUT_RPM
- Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Turbine speed VELOZ_SPD_NT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Valvematic current angle VELOZ_VALVEMATIC_CURRENT
- Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2021 to 2026.
Valvematic, target angle VELOZ_VALVEMATIC_TGT_ANG
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2021 to 2026.
Variable valve timing aim angle 1 VELOZ_VARIABLE_VLV_TIM_AIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2021 to 2026.
Variable valve timing change angle 1 VELOZ_VARIABLE_VLV_TIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 639 °
- Unit
- °
In testing for 2021 to 2026.
Variable valve timing control status 1 on VELOZ_VARIABLE_VLV_TIM_1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Variable valve timing oil control valve duty 1 VELOZ_VARIABLE_VLV_TIM_OIL_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2021 to 2026.
Variable valve timing oil temperature VELOZ_VVTOTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x60 = 96 → = 56 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Vehicle speed VELOZ_VSS_21
- Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2021 to 2026.
Vehicle speed sensor test result, incomplete VELOZ_SPD_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Warm-up cycles since DTCs cleared VELOZ_WARMUP_CYCLES_DTC_CLEARED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfires
All cylinders misfire count VELOZ_ALL_CYLINDERS_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Cylinder #1 misfire count VELOZ_CYL1_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Cylinder #2 misfire count VELOZ_CYL2_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Cylinder #3 misfire count VELOZ_CYL3_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Cylinder #4 misfire count VELOZ_CYL4_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire load VELOZ_MISFIRE_LOAD_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 2021 to 2026.
Misfire margin VELOZ_MISFIRE_MARGIN_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2021 to 2026.
Fluids
Distance since oil change VELOZ_OIL_CHANGE_ODO
- Service 21
PID 41 - Module
7C0 → 7C8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 41038.272 km
- Unit
- km
In testing for 2021 to 2026.
Fuel
Fuel cut VELOZ_FUEL_CUT
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Fuel cut VELOZ_FUEL_CUT_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 121 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Fuel cut time VELOZ_FUEL_CUT_TIME
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 68734.9511
- Unit
- Number
In testing for 2021 to 2026.
Fuel injection timing VELOZ_FUEL_INJ_TIM
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2021 to 2026.
Fuel level, volume VELOZ_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 21
PID 29 - Module
7C0 → 7C8 - Every
5 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 21 gal
- Unit
- gal
0x47 = 71 → = 9.379128 gal
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Fuel pump/speed status on VELOZ_FUEL_PMP_SPD_STAT_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2024.
Target air-fuel equivalence ratio VELOZ_LAMBDA_TARGET
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2021 to 2026.
Lights
Check engine SW VELOZ_CHECK_ENGINE_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Hazard switch history VELOZ_HAZARD_SWITCH_HISTORY
- Service 21
PID BC - Module
7B0 → 7B8 - Every
3600 s - Testing
Bit 2 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | INCOMPLETE | Incomplete |
1 | COMPLETE | Complete |
In testing for 2021 to 2026.
Oil pressure switch VELOZ_EOP_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 35 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
P-seatbelt buckle SW VELOZ_P_SEATBELT_BUCKLE_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rheostat VELOZ_RHEOSTAT
Higher values are brighter
- Service 21
PID 68 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Stop light VELOZ_STOP_LIGHT_SW
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Stop light VELOZ_STOP_LIGHT_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Stop light relay VELOZ_STOP_LIGHT_RELAY
- Service 21
PID 3C - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Tail cancel SW VELOZ_TAIL_CANCEL_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Movement
Accelerator fully close learn 1 VELOZ_ACCEL_FULLY_CLOSE_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2021 to 2026.
Accelerator fully close learn 2 VELOZ_ACCEL_FULLY_CLOSE_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2021 to 2026.
Accelerator idle position on VELOZ_ACCEL_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 148 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Accelerator position VELOZ_ACCEL_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2021 to 2026.
Accelerator sensor out, number 1 VELOZ_ACCEL_SENS_OUT_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Accelerator sensor out, number 2 VELOZ_ACCEL_SENS_OUT_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2021 to 2026.
Average engine speed of all cylinders VELOZ_AV_RPM_ALL_CYL
Pelican can show this parameter as the engine speed.
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Cruise control speed VELOZ_CRUISE_CTRL_SPD
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2021 to 2026.
Engine speed of cylinder 1 VELOZ_RPM_CYL_1
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Engine speed of cylinder 2 VELOZ_RPM_CYL_2
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Engine speed of cylinder 3 VELOZ_RPM_CYL_3
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Engine speed of cylinder 4 VELOZ_RPM_CYL_4
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Front left wheel acceleration VELOZ_FL_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2021 to 2026.
Front left wheel speed VELOZ_TIRE_FL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Front left wheel speed? VELOZ_FL_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Front right wheel acceleration VELOZ_FR_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2021 to 2026.
Front right wheel speed VELOZ_TIRE_FR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Front right wheel speed? VELOZ_FR_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
High voltage, target engine speed VELOZ_HIGH_V_TGT_RPM
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Minimum engine speed VELOZ_MIN_RPM
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Rear left wheel acceleration VELOZ_RL_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2021 to 2026.
Rear left wheel speed VELOZ_TIRE_RL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Rear left wheel speed? VELOZ_RL_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Rear right wheel acceleration VELOZ_RR_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2021 to 2026.
Rear right wheel speed VELOZ_TIRE_RR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Rear right wheel speed? VELOZ_RR_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Speed VELOZ_VSS_7C0
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7C0 → 7C8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2021 to 2026.
Vehicle speed VELOZ_VEHICLE_SPEED_7E0
Pelican can show this parameter as the speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2021 to 2026.
Vehicle speed VELOZ_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7B0 → 7B8 - Every
200 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 323.85 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2024.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2024.
Orientation
Deceleration VELOZ_DECEL
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
In testing for 2021 to 2026.
Deceleration 2 VELOZ_DECEL_2
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
In testing for 2021 to 2026.
Deceleration open VELOZ_DECELERATION_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Lateral g VELOZ_LAT_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Longitudinal g VELOZ_LNG_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Yaw rate value, degrees/sec VELOZ_YAW_RATEConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x80 = 128 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Yaw rate, error? VELOZ_YAW_RATE_OPEN_ERROR
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Yaw rate, sensor 1 VELOZ_YAW_1
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2021 to 2026.
Yaw rate, sensor 2 VELOZ_YAW_2
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2021 to 2026.
Zero point of deceleration VELOZ_ZP_DEC
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
In testing for 2021 to 2026.
Zero point of deceleration 2 VELOZ_ZP_DEC2
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
In testing for 2021 to 2026.
Zero point of yaw rate VELOZ_ZERO_POINT_OF_YAW_RATE
- Service 21
PID A1 - Module
7B0 → 7B8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2021 to 2026.
Zero point of yaw rate, degrees/sec VELOZ_ZP_YAW
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2021 to 2026.
Seatbelts
Reverse beep VELOZ_REVERSE_BEEP
- Service 21
PID AC - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- On or off
In testing for 2021 to 2026.
Seat belt beep, driver VELOZ_SEAT_BELT_BEEP_DRIVER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Seat belt beep, passenger VELOZ_SEAT_BELT_BEEP_PASSENGER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Seat belt beep, reminder VELOZ_SEAT_BELT_BEEP_REMINDER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Tires
Brake assist status VELOZ_BA_CTRL_STATUS
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Front left wheel ABS status VELOZ_FL_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Front left wheel vehicle stability control status VELOZ_FL_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Front right wheel ABS status VELOZ_FR_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Front right wheel cylinder open VELOZ_FR_WHEEL_CYLINDER_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2021 to 2026.
Front right wheel vehicle stability control status VELOZ_FR_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Predictive brake assist status VELOZ_PBA_CTRL_STATUS
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rear left wheel ABS status VELOZ_RL_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rear left wheel EBS status VELOZ_RL_WHEEL_EBD_CTRL
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rear left wheel vehicle stability control status VELOZ_RL_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rear right wheel ABS status VELOZ_RR_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rear right wheel EBS status VELOZ_RR_WHEEL_EBD_CTRL
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Rear right wheel vehicle stability control status VELOZ_RR_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Traction control, engine status VELOZ_TRC_TRAC__ENGINE_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Traction control, status VELOZ_TRC_TRAC__CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Wheel cylinder pressure VELOZ_WHEEL_CYLINDER_PRESSURE
- Service 21
PID 07 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2021 to 2026.
Transmission
Current gear VELOZ_GEAR_V2
- Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Torque converter and TE1 on VELOZ_TQ_CONV_TE1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Transmission fluid temperature, variant 5 VELOZ_ATF_T_V_5
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission fluid temperature, variant 8 VELOZ_ATF_T_V_8
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission fluid temperature, variant 14 VELOZ_ATF_T_V_14
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission fluid temperature, variant 21 VELOZ_ATF_T_V_21
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission oil pressure calibration, complete VELOZ_TRANS_OIL_PRESS
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2021 to 2026.
Trips
Previous trip distance VELOZ_PREV_TRIP_DSTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Toyota Veloz.
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
0x0000 = 0 → = 0 km
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.