Parameters
The Volvo S90 has 220 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery state of charge S90_12V_BAT_ST_CHG
- Service 22
DID 4946 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4294 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Auxiliary battery current S90_AUXILIARY_BAT
- Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -127 to 128 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Auxiliary battery temperature S90_AUXILIARY_BAT_T
- Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Auxiliary battery voltage S90_AUXILIARY_BAT_V
- Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Average static low range battery current S90_AVG_STATIC_LOW_RANGE
- Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Battery current S90_BAT_CURRENT
- Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 3583 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Battery relay S90_BAT_RELAY
- Service 22
DID D953 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery state of charge S90_BAT_ST_CHG
- Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Battery voltage S90_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1643 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Boost pressure after turbocharger S90_BOOST_P_AFTER
- Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -0.0534 to 500 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charge air pressure S90_CHG_AIR_P
- Service 22
DID EE3E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger cable current S90_CHARGER_CABLE
- Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -410 to 6143 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging socket lock S90_CHG_SOCKET_LOCKED
- Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2017. Supported for 2018 to 2020.
DC charger current S90_DC_CHARGER_CURRENT
- Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
DC charger voltage S90_DC_CHARGER_V
- Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery current S90_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery state of charge S90_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery voltage S90_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, average temperature S90_HVBAT_AVG_T
- Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, coolant pump speed, actual S90_HVBAT_CLT_PMP_SPD_ACT
- Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, coolant pump speed, requested S90_HVBAT_CLT_PMP_SPD
- Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, high-voltage coolant heater fuse voltage S90_HVBAT_HVCH_FUSE_V
- Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, IEM fuse voltage S90_HVBAT_IEM_FUSE_V
- Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, IGM fuse voltage S90_HVBAT_IGM_FUSE_V
- Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, inlet coolant temperature S90_HVBAT_INLET_ECT
- Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, max temperature S90_HVBAT_MAX_T
- Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, OBC fuse voltage S90_HVBAT_OBC_FUSE_V
- Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Main charger current S90_MAIN_CHARGER_CURRENT
- Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Main charger voltage S90_MAIN_CHARGER_V
- Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Module voltage S90_MODULE_V
- Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Start/stop battery relay S90_START_STOP_BAT_RELAY
- Service 22
DID EF51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Start/stop secondary battery relay S90_START_STOP_SECONDARY
- Service 22
DID EF52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Supercharger clutch, requested position S90_SUPERCHARGER_CLU_REQ
- Service 22
DID EE84 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission control module supply voltage S90_MECU_SUP_V
- Service 22
DID DD02 - Module
7E1 → 1EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Climate
Auxiliary water pump duty cycle S90_AUXILIARY_WATER_PMP
- Service 22
DID 4336 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Evaporator temperature S90_EVAPORATOR_T
- Service 22
DID 984F - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Evaporator temperature v.2 S90_EVAPORATOR_T_V_2
- Service 22
DID 9820 - Module
D01A → 1F422E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -409 to 406 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Fuel-operated heater, inlet water temperature S90_FOH_INLET_WATER_T
- Service 22
DID 43BE - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel-operated heater, outlet water temperature S90_FOH_OUTLET_WATER_T
- Service 22
DID 43BE - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Heat exchanger temperature S90_HEAT_EXCHANGER_T
- Service 22
DID 9850 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Heat exchanger temperature v.2 S90_HEAT_EXCHANGER_T_V_2
- Service 22
DID 4337 - Module
D01A → 1F422E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -409 to 406 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
High-voltage coolant heater coolant inlet temperature S90_HVCH_CLT_INLET_T
- Service 22
DID 4344 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High-voltage coolant heater coolant outlet temperature S90_HVCH_CLT_OUTLET_T
- Service 22
DID 4344 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High-voltage coolant heater current consumption S90_HVCH_CURRENT_CONS
- Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High-voltage coolant heater power consumption S90_HVCH_POWER_CONS
- Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High-voltage coolant heater required power consumption S90_HVCH_REQUIRED_POWER
- Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Interior temperature S90_INTERIOR_T
- Service 22
DID 9843 - Module
D01A → 1F422E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 144 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Control
Brake pedal position S90_BRAKE_PEDAL_POS
- Service 22
DID E504 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Brake switch S90_BRAKE_SWITCH
- Service 22
DID D943 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Front left brake disc temperature S90_FL_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Front right brake disc temperature S90_FR_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Rear left brake disc temperature S90_RL_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Rear right brake disc temperature S90_RR_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Start/stop brake booster pressure S90_START_STOP_BRAKE_P
- Service 22
DID EF44 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2017. Supported for 2018 to 2020.
Engine
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2018. Supported for 2017, 2019 to 2020.
Accelerator pedal position S90_M3_APP_ECM
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air conditioning pressure S90_AC_P
- Service 22
DID D900 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air conditioning pressure S90_AC_P_D016
- Service 22
DID EE34 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air conditioning relay S90_AC_RELAY
- Service 22
DID D909 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air flow/cycle, mg/s S90_AIR_FLOW_CYCLE_MG_S
- Service 22
DID D916 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air mass, desired S90_AIR_MASS_DES
- Service 22
DID D91F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Alternator, amps S90_ALTERNATOR_AMPS
- Service 22
DID D924 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Average charging time left S90_AVG_CHG_TIME_LEFT
- Service 22
DID EEB6 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost air pressure after turbocharger S90_BOOST_AIR_P_AFTER
- Service 22
DID 033E - Module
D016 → 1EC60E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Boost air temperature S90_BOOST_AIR_T
- Service 22
DID 0341 - Module
D016 → 1EC60E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Boost air temperature S90_BOOST_AIR_T_7E0
- Service 22
DID 0341 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost pressure S90_BOOST_P
- Service 22
DID D941 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost pressure, desired value S90_BOOST_P_DES
- Service 22
DID D9E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Calculated load S90_CALC_LOAD
Pelican can show this parameter as the engine load.
- Service 22
DID F404 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017. Supported for 2018 to 2020.
Charging state S90_CHG_ST
- Service 22
DID EE1D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018. Supported for 2017, 2019 to 2020.
Control module temperature S90_CTRL_MODULE_T
- Service 22
DID D9B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant pump relay S90_CLT_PMP_RELAY
- Service 22
DID D95B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 1 misfire S90_MIS_1
- Service 22
DID F6A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 1 misfire average S90_MIS_AVG_1
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 2 misfire S90_MIS_2
- Service 22
DID F6A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 2 misfire average S90_MIS_AVG_2
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 3 misfire S90_MIS_3
- Service 22
DID F6A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 3 misfire average S90_MIS_AVG_3
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 4 misfire S90_MIS_4
- Service 22
DID F6A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 4 misfire average S90_MIS_AVG_4
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 5 misfire average S90_MIS_AVG_5
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 6 misfire average S90_MIS_AVG_6
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 7 misfire average S90_MIS_AVG_7
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 8 misfire average S90_MIS_AVG_8
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Electric rear axle drive calculated torque S90_ERAD_CALC_TQ
- Service 22
DID EF12 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Electric rear axle drive calculated torque S90_ERAD_CALC_TQ_D016
- Service 22
DID EE09 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine coolant fan S90_ENG_CLT_FAN
- Service 22
DID EE6F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017 to 2018. Supported for 2019 to 2020.
Engine oil pressure S90_EOP
- Service 22
DID EF4E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine oil pressure S90_EOP_D016
- Service 22
DID EE37 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine oil temperature S90_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID D9DC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine oil temperature S90_EOT_D016
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID EE58 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2018. Supported for 2017, 2019 to 2020.
Engine torque S90_ENG_TQ
- Service 22
DID DA89 - Module
D016 → 1EC64E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 6041 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Exhaust gas recirculation bypass valve S90_EGR_BYPASS_VLV
- Service 22
DID EE7F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation cooler bypass actuator position S90_EGR_COOLER_BYPASS
- Service 22
DID DAD2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation valve position sensor S90_EGR_VLV_POS_SENS
- Service 22
DID DAAD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation valve, commanded position S90_EGR_VLV_CMD_POS
- Service 22
DID DC01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation valve, commanded position II S90_EGR_VLV_CMD_POS_II
- Service 22
DID D96D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fan S90_FAN
- Service 22
DID DC02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Front oxygen sensor heating S90_FRONT_OXYGEN_SENS
- Service 22
DID DA59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Grill shutter open S90_GRILL_SHUTTER_OPEN
- Service 22
DID 0707 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage ED coolant temperature 2 S90_HIGH_V_ED_ECT_2
- Service 22
DID EF73 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage motor coolant pump S90_HIGH_V_MOTOR_CLT_PMP
- Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage system current S90_HIGH_V_SYSTEM
- Service 22
DID EF13 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -250 to 260 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Ignition angle before top dead center S90_IGN_ANG_BTDC
- Service 22
DID F40E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Intake air temperature, manifold sensor S90_TMAP_IAT
- Service 22
DID D9AB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leading A/T S90_LEADING_T
- Service 22
DID 1E2F - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Load S90_LOAD
- Service 22
DID F443 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 APP, CAN S90_M3_APP_CAN
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 diff.press. S90_M3_DIFF_PRESS
- Service 22
DID D9F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 EGR DC S90_M3_EGR_DC
- Service 22
DID D96C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 IAT, butterfly S90_M3_IAT_BUTTERFLY
- Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 IAT, MAF S90_M3_IAT_MAF
- Service 22
DID D91C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfire catalytic damage total - petrol S90_MIS_CATALYTIC_DAMAGE
- Service 22
DID DA03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfire emission related total - petrol S90_MIS_EMISSION_RELATED
- Service 22
DID DA04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfires, cylinder 2 S90_MIS_2_D016
- Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfires, cylinder 3 S90_MIS_3_D016
- Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Module current S90_MODULE_CURRENT
- Service 22
DID 1946 - Module
D016 → 1EC70E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
On-board charger module temperature S90_OBC_T
- Service 22
DID EE19 - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Rear oxygen sensor heating S90_REAR_OXYGEN_SENS
- Service 22
DID DB77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018. Supported for 2017, 2019 to 2020.
Slave A/T S90_SLAVE_T
- Service 22
DID 1E1B - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
SLC1 current S90_SLC1_CURRENT
- Service 22
DID D90C - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
SLC2 current S90_SLC2_CURRENT
- Service 22
DID D90F - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
SLC3 current S90_SLC3_CURRENT
- Service 22
DID D910 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Starter relay S90_STARTER_RELAY
- Service 22
DID D950 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Starter relay 1 S90_STARTER_RELAY_1
- Service 22
DID DA12 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Starter relay 2 S90_STARTER_RELAY_2
- Service 22
DID EEEB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
System relay S90_SYSTEM_RELAY
- Service 22
DID D94F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Throttle absolute position S90_THROTTLE_ABS_POS
Pelican can show this parameter as the throttle position.
- Service 22
DID F411 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Time since engine start S90_TIME_SINCE_ENG_START
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid S90_LOCK_UP_SOLENOID_SLU_7E1
- Service 22
DID DA4C - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid current S90_LOCK_UP_SOLENOID_SLU_CURRENT
- Service 22
DID 1E47 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid current, requested S90_LOCK_UP_SOLENOID_SLU
- Service 22
DID 1E41 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid, requested S90_LOCK_UP_SOLENOID_SLU_REQ
- Service 22
DID DA4B - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fixed lock-up S90_FIXED_LOCK_UP
- Service 22
DID 1E24 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission kickdown S90_KICKDOWN
- Service 22
DID DCE4 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current S90_LINEAR_P_SOLENOID_SLT
- Service 22
DID 1E40 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current S90_LINEAR_P_SOLENOID_SLT_CURRENT
- Service 22
DID DA4A - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current, requested S90_LINEAR_P_SOLENOID
- Service 22
DID 1E1E - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current, requested S90_LINEAR_P_SOLENOID_SLT_REQ
- Service 22
DID DA49 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL1 current S90_LINEAR_P_SOLENOID_SL1
- Service 22
DID DA4E - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL1, requested, current S90_LINEAR_P_SOLENOID_SL1_REQ
- Service 22
DID DA4D - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL2 current S90_LINEAR_P_SOLENOID_SL2
- Service 22
DID DA50 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL2, requested, current S90_LINEAR_P_SOLENOID_SL2_REQ
- Service 22
DID DA4F - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL3 current S90_LINEAR_P_SOLENOID_SL3
- Service 22
DID DA52 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL3, requested, current S90_LINEAR_P_SOLENOID_SL3_REQ
- Service 22
DID DA51 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLB1, requested, current S90_LINEAR_P_SOLENOID_SLB1_REQ
- Service 22
DID 1E45 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC1 current S90_LINEAR_P_SOLENOID_SLC1
- Service 22
DID 1E48 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC1, requested, current S90_LINEAR_P_SOLENOID_SLC1_REQ
- Service 22
DID 1E42 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC2 current S90_LINEAR_P_SOLENOID_SLC2
- Service 22
DID 1E49 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC2, requested, current S90_LINEAR_P_SOLENOID_SLC2_REQ
- Service 22
DID 1E43 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC3 current S90_LINEAR_P_SOLENOID_SLC3
- Service 22
DID 1E4A - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC3, requested, current S90_LINEAR_P_SOLENOID_SLC3_REQ
- Service 22
DID 1E44 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission lock-up function S90_LOCK_UP_FUNCTION
- Service 22
DID DA3C - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -0.333 to 84.66
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission selector S90_SELECTOR
- Service 22
DID DCEA - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission solenoid S1 status S90_SOLENOID_S1_STAT
- Service 22
DID DD89 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission solenoid S2 status S90_SOLENOID_S2_STAT
- Service 22
DID DD8A - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission start lock - start approved S90_START_LOCK_START
- Service 22
DID DF08 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission torque S90_TQ
- Service 22
DID DD8D - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission torque limiting S90_TQ_LIMITING
- Service 22
DID DCF0 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Turbo bypass valve opened S90_TURBO_BYPASS_VLV
- Service 22
DID D9EE - Module
D016 → 1EC60E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Turbo control valve wastegate S90_TURBO_CTRL_VLV_WASTEGATE
- Service 22
DID DC10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 800 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Turbo control valve, bypass or variable nozzle S90_TURBO_CTRL_VLV
- Service 22
DID DC00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 800 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Wastegate position S90_WASTEGATE_POS
- Service 22
DID DC80 - Module
D016 → 1EC60E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018. Supported for 2017, 2020.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2018. Supported for 2017, 2020.
Fuel
Fuel filter heater S90_FUEL_FLT_HEATER
- Service 22
DID DC14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel filter heater S90_FUEL_FLT_HEATER_7E0
- Service 22
DID DB35 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel high pressure S90_FUEL_HIGH_P
- Service 22
DID EE4F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel level input S90_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel low pressure S90_FUEL_LOW_P
- Service 22
DID EE57 - Module
D016 → 1EC60E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Fuel pressure S90_FUEL_P
- Service 22
DID F423 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553500
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel pressure nominal value S90_FUEL_P_NOMINAL
- Service 22
DID D9FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553500
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel pressure regulator valve current S90_FUEL_P_REGULATOR_VLV
- Service 22
DID D9EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel pump low pressure side duty cycle S90_FUEL_PMP_LOW_P_SIDE
- Service 22
DID EF59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel temperature S90_FUEL_T
- Service 22
DID D99C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel volume control valve S90_FUEL_VOLUME_CTRL_VLV
- Service 22
DID DAD5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuel volume control valve S90_FUEL_VOLUME_CTRL_VLV_7E0
- Service 22
DID DC13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Movement
Accelerator pedal position S90_ACCEL_PEDAL_POS
- Service 22
DID DD8E - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Driven shaft speed S90_DRIVEN_SHFT_SPD
- Service 22
DID DA38 - Module
D016 → 1EC64E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Tires
Front left wheel speed S90_FL_WHL_SPD
- Service 22
DID 2B06 - Module
D016 → 1EC62E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Front right wheel speed S90_FR_WHL_SPD
- Service 22
DID 2B07 - Module
D016 → 1EC62E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Rear left wheel speed S90_RL_WHL_SPD
- Service 22
DID 2B08 - Module
D016 → 1EC62E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Rear right wheel speed S90_RR_WHL_SPD
- Service 22
DID 2B09 - Module
D016 → 1EC62E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Transmission
A/T converter S90_T_CONV
- Service 22
DID 1E14 - Module
7E1 → 1EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
AT, actual gear ratio S90_ACT_GEAR_RAT
- Service 22
DID 1E16 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Clutch 1 temperature S90_CLU_1_T
- Service 22
DID D926 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Clutch 2 temperature S90_CLU_2_T
- Service 22
DID D940 - Module
D016 → 1EC64E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Clutch actuator 1 temperature S90_CLU_ACTUATOR_1_T
- Service 22
DID D96B - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Clutch actuator 2 temperature S90_CLU_ACTUATOR_2_T
- Service 22
DID D974 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Clutch pump duty S90_CLU_PMP_DUTY
- Service 22
DID D920 - Module
D016 → 1EC70E80 - Every
1 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Gear S90_GEAR
- Service 22
DID DA85 - Module
D016 → 1EC64E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Gear ratio expected S90_GEAR_RAT_EXPECTED
- Service 22
DID DA47 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Gear ratio, actual S90_GEAR_RAT_ACT
- Service 22
DID DA34 - Module
D016 → 1EC64E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Gear ratio, actual S90_GEAR_RAT_ACT_7E1
- Service 22
DID DA34 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Gear ratio, requested S90_GEAR_RAT_REQ
- Service 22
DID DA47 - Module
D016 → 1EC64E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Gear, AT position S90_GEAR_POS
- Service 22
DID DA40 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock S90_TQ_CONV_LOCK
- Service 22
DID DA3C - Module
D016 → 1EC64E80 - Every
250 ms - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Transmission expected gear ratio S90_EXPECTED_GEAR_RAT
- Service 22
DID 1E19 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fluid temperature S90_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID DA3B - Module
D016 → 1EC64E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Transmission fluid temperature S90_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E3F - Module
7E1 → 1EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fluid temperature S90_ATF_T_D016
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D900 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768000 to 32767000 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fluid temperature S90_ATF_T_D016_D016
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D90D - Module
D016 → 1EC64E80 - Every
5 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Transmission fluid temperature, variant 2 S90_ATF_T_VAR_2
- Service 22
DID D904 - Module
7E1 → 1EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fluid temperature, variant 2 S90_ATF_T_VAR_2_7E1
- Service 22
DID DA3B - Module
7E1 → 1EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fluid temperature, variant 3 S90_ATF_T_VAR_3
- Service 22
DID D9A1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission gear S90_GEAR_7E1
- Service 22
DID DD81 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission gear selector p, 0 r, 1 n, 2 d, 3 S90_GEAR_SELECTOR_P_0_R_1_N_2_D_3
- Service 22
DID 6310 - Module
7E1 → 1EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Trips
Distance since last service S90_DIST_SINCE_SERVICE
- Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Odometer S90_MILEAGE_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Odometer S90_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
D016 → 1EC64E80 - Every
30 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Odometer S90_ODO_TCM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E1 → 1EC - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Odometer at last service S90_ODO_LAST_SERVICE
- Service 22
DID D906 - Module
D018 → 1F002E80 - Every
30 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.
Total distance S90_DEM_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
D016 → 1EC70E80 - Every
30 s - Testing for 2016 to 2017, 2019 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Supported for 2018.