Volvo XC40 Recharge

Parameters

The Volvo XC40 Recharge has 118 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge XC40R_12V_BAT_ST_CHG

  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×102415625
Range
0 to 4294 %
Unit
%

In testing for 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery state of charge XC40R_12V_BAT_ST_CHG

  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×102415625
Range
0 to 4294 %
Unit
%

In testing for 2020 to 2026.

Auxiliary battery current XC40R_AUXILIARY_BAT

  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2020 to 2026.

Auxiliary battery temperature XC40R_AUXILIARY_BAT_T

  • Service 22DID 40D3
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

Auxiliary battery voltage XC40R_AUXILIARY_BAT_V

  • Service 22DID 417E
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2026.

Average static low range battery current XC40R_AVG_STATIC_LOW_RANGE

  • Service 22DID 4025
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 mA
Unit
mA

In testing for 2020 to 2026.

Battery current XC40R_BAT_CURRENT

  • Service 22DID 4090
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−512
Range
-512 to 3583 A
Unit
A

In testing for 2020 to 2026.

Battery voltage XC40R_BAT_V

  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40+5
Range
0 to 1643 V
Unit
V

In testing for 2020 to 2026.

Charge power limit XC40R_CHG_POWER_LIM

  • Service 22DID 489C
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×415625
Range
0 to 4294 kW
Unit
kW

In testing for 2020 to 2026.

Charger cable selected current XC40R_CHARGER_CABLE

  • Service 22DID EE8D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−410
Range
-410 to 6143 A
Unit
A

In testing for 2020 to 2026.

Charging socket, locked XC40R_CHG_SOCKET_LOCKED

  • Service 22DID EE8C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Control module supply voltage XC40R_ENG_CTRL_MODULE_SUP_V

  • Service 22DID F442
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2021. Supported for 2024.

DC charger current XC40R_DC_CHARGER_CURRENT

  • Service 22DID EE16
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2020 to 2026.

DC charger voltage XC40R_DC_CHARGER_V

  • Service 22DID EE17
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2020 to 2026.

Discharge power limit XC40R_DCHG_POWER_LIM

  • Service 22DID 489E
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×415625
Range
0 to 4294 kW
Unit
kW

In testing for 2020 to 2026.

External temperature sensor, HV battery cooling module XC40R_EXTERNAL_T_SENS

  • Service 22DID EE46
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Fuse DC charging voltage XC40R_FUSE_DC_CHG_V

  • Service 22DID 498B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2020 to 2026.

High voltage battery - voltage at IEM fuse XC40R_HVBAT_V_IEM_FUSE

  • Service 22DID 4859
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2020 to 2026.

High voltage battery - voltage at IHFA fuse XC40R_HVBAT_V_IHFA_FUSE

  • Service 22DID 4858
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2020 to 2026.

High voltage battery cell voltage sum XC40R_HVBAT_CELL_VOLTAGES

  • Service 22DID 497C
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

High voltage battery contactor voltage XC40R_HVBAT_CONTACTOR_V

  • Service 22DID 4857
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2020 to 2026.

High voltage battery coolant inlet temperature XC40R_HVBAT_CLT_INLET_T

  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2020 to 2026.

High voltage battery coolant outlet temperature XC40R_HVBAT_CLT_OUTLET_T

  • Service 22DID 4990
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2020 to 2026.

High voltage battery current XC40R_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2020 to 2026.

High voltage battery negative contactor voltage XC40R_HVBAT_NEGATIVE_V

  • Service 22DID 4A58
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 V
Unit
V

In testing for 2020 to 2026.

High voltage battery state of charge XC40R_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 %
Unit
%

In testing for 2020 to 2026.

High voltage battery state of health XC40R_HVBAT_ST_HEALTH

Pelican can show this parameter as the state of health.

  • Service 22DID 496D
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100
Range
0 to 42949672 %
Unit
%

In testing for 2020 to 2026.

High voltage battery voltage XC40R_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2020 to 2026.

High voltage battery, average temperature XC40R_HVBAT_AVG_T

  • Service 22DID 491B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−50
Range
-50 to 605 °C
Unit
°C

In testing for 2020 to 2026.

High voltage battery, coolant pump speed, actual XC40R_HVBAT_CLT_PMP_SPD_ACT

  • Service 22DID 4867
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2020 to 2026.

High voltage battery, coolant pump speed, requested XC40R_HVBAT_CLT_PMP_SPD

  • Service 22DID 4866
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2020 to 2026.

High voltage battery, high-voltage coolant heater fuse voltage XC40R_HVBAT_HVCH_FUSE_V

  • Service 22DID 480A
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

High voltage battery, IEM fuse voltage XC40R_HVBAT_IEM_FUSE_V

  • Service 22DID 4808
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

High voltage battery, IGM fuse voltage XC40R_HVBAT_IGM_FUSE_V

  • Service 22DID 4809
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

High voltage battery, max temperature XC40R_HVBAT_MAX_T

  • Service 22DID 4945
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val100−50
Range
-50 to 605 °C
Unit
°C

In testing for 2020 to 2026.

High voltage battery, OBC fuse voltage XC40R_HVBAT_OBC_FUSE_V

  • Service 22DID 480B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

High voltage system voltage XC40R_HIGH_V_SYSTEM_V

  • Service 22DID 985C
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 V
Unit
V

In testing for 2020 to 2026.

High voltage system voltage XC40R_HIGH_V_SYSTEM_V_D016

  • Service 22DID 985C
  • ModuleD016 → 1ED24E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 V
Unit
V

In testing for 2020 to 2026.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2024.

Main charger current XC40R_MAIN_CHARGER_CURRENT

  • Service 22DID EE15
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2020 to 2026.

Main charger voltage XC40R_MAIN_CHARGER_V

  • Service 22DID EE1C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2020 to 2026.

Module voltage XC40R_MODULE_V

  • Service 22DID D111
  • ModuleD016 → 1EC70E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2026.

State of charge XC40_SOC

  • Service 22DID 4028
  • ModuleD01A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2020, 2022 to 2026. Not supported for 2021.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021. Supported for 2024.

Auxiliary water pump duty cycle XC40R_AUXILIARY_WATER_PMP

  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Evaporator temperature, variant 2 XC40R_EVAPORATOR_T_V_2

  • Service 22DID 9820
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×165
Range
-409 to 406 °C
Unit
°C

In testing for 2020 to 2026.

Fuel-operated heater, inlet water temperature XC40R_FOH_INLET_WATER_T

  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Fuel-operated heater, outlet water temperature XC40R_FOH_OUTLET_WATER_T

  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Heat exchanger temperature XC40R_HEAT_EXCHANGER_T

  • Service 22DID 9850
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2020 to 2026.

Heat exchanger temperature, variant 2 XC40R_HEAT_EXCHANGER_T_V_2

  • Service 22DID 4337
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×165
Range
-409 to 406 °C
Unit
°C

In testing for 2020 to 2026.

High-voltage coolant heater coolant inlet temperature XC40R_HVCH_CLT_INLET_T

  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

High-voltage coolant heater coolant outlet temperature XC40R_HVCH_CLT_OUTLET_T

  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Control

Front left brake disc temperature XC40R_FL_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2020 to 2026.

Front right brake disc temperature XC40R_FR_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2020 to 2026.

Rear left brake disc temperature XC40R_RL_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2020 to 2026.

Rear right brake disc temperature XC40R_RR_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2020 to 2026.

Pedals

Accelerator pedal position XC40_APP_POS

  • Service 22DID EE6F
  • ModuleD016
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020, 2022 to 2026. Not supported for 2021.

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2024.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021. Supported for 2024.

Engine

Actual power XC40R_ACT_POWER

  • Service 22DID 4A88
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kW
Unit
kW

In testing for 2020 to 2026.

Air conditioning compressor module A current XC40R_AC_COMP_MODULE

  • Service 22DID 0331
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 A
Unit
A

In testing for 2020 to 2026.

Air conditioning compressor module a status XC40R_AC_COMP_MODULE_STAT

  • Service 22DID 032F
  • ModuleD016 → 1EC04E80
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Air conditioning pressure XC40R_AC_P

  • Service 22DID EE34
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2020 to 2026.

Average charging time left XC40R_AVG_CHG_TIME_LEFT

  • Service 22DID EEB6
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2020 to 2026.

Charging state XC40R_CHG_ST

  • Service 22DID EE1D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Compressor inlet sensor pressure XC40R_COMP_INLET_SENS_P

  • Service 22DID 0303
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2020 to 2026.

Compressor inlet sensor temperature XC40R_COMP_INLET_SENS_T

  • Service 22DID EE36
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Compressor inlet sensor temperature XC40R_COMP_INLET_SENS_T_D016

  • Service 22DID 0303
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2020 to 2026.

Compressor outlet sensor pressure XC40R_COMP_OUTLET_SENS_P

  • Service 22DID 0329
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2020 to 2026.

Compressor outlet sensor temperature XC40R_COMP_OUTLET_SENS_T

  • Service 22DID EE38
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Compressor outlet sensor temperature XC40R_COMP_OUTLET_SENS_T_D016

  • Service 22DID 0329
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2020 to 2026.

Days since last service XC40R_DAYS_SINCE_SERVICE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2020 to 2026.

Electric drivetrain coolant temperature, IEM inlet XC40R_ELEC_DRIVETRAIN_ECT

  • Service 22DID 985E
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2020 to 2026.

Electric drivetrain coolant temperature, IEM outlet XC40R_ELEC_DRIVETRAIN_ECT_IEM

  • Service 22DID 985E
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2020 to 2026.

Electric drivetrain coolant temperature, IHFA inlet XC40R_ELEC_DRIVETRAIN_ECT_IHFA

  • Service 22DID 985E
  • ModuleD016 → 1ED24E80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2020 to 2026.

Electric drivetrain coolant temperature, IHFA outlet XC40R_ELEC_DRIVETRAIN_ECT_IHFA_OUTLET

  • Service 22DID 985E
  • ModuleD016 → 1ED24E80
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2020 to 2026.

Electric front axle drive torque XC40R_ELECTRICAL_FRONT

  • Service 22DID 49D4
  • ModuleD016 → 1ED24E80
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val−1024
Range
-2147484672 to 2147482623 N·m
Unit
N·m

In testing for 2020 to 2026.

Electric rear axle drive calculated torque XC40R_ERAD_CALC_TQ

  • Service 22DID EF12
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4−8188
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 2020 to 2026.

Electric rear axle drive calculated torque XC40R_ERAD_CALC_TQ_D016

  • Service 22DID EE09
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4−8188
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 2020 to 2026.

Electric rear axle drive motor winding temperature sensor 1 XC40R_ERAD_MOTOR_WINDING_T_1

  • Service 22DID 4A00
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 °C
Unit
°C

In testing for 2020 to 2026.

Electric rear axle drive motor winding temperature sensor 2 XC40R_ERAD_MOTOR_WINDING_T_2

  • Service 22DID 4A01
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 °C
Unit
°C

In testing for 2020 to 2026.

Evaporator temperature XC40R_EVAPORATOR_T

  • Service 22DID 984F
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2020 to 2026.

High voltage coolant heater A, inlet temperature XC40R_HIGH_V_CLT_HEATER_T

  • Service 22DID 032B
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2020 to 2026.

High voltage coolant heater A, outlet temperature XC40R_HIGH_V_CLT_HEATER_OUTLET_T

  • Service 22DID 032B
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2020 to 2026.

High voltage ED coolant temperature 2 XC40R_HIGH_V_ED_ECT_2

  • Service 22DID EF73
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

High voltage system current XC40R_HIGH_V_SYSTEM

  • Service 22DID 9861
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10+40
Range
-3236 to 3316 A
Unit
A

In testing for 2020 to 2026.

High voltage system current XC40R_HIGH_V_SYSTEM_CURRENT

  • Service 22DID 9861
  • ModuleD016 → 1ED24E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10+40
Range
-3236 to 3316 A
Unit
A

In testing for 2020 to 2026.

High voltage system current XC40R_HIGH_V_SYSTEM_XC

  • Service 22DID EF13
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−250
Range
-250 to 260 A
Unit
A

In testing for 2020 to 2026.

High-voltage coolant heater current XC40R_CURRENT_CONS_HVCH

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

In testing for 2020 to 2026.

High-voltage coolant heater power XC40R_CURRENT_CONS_HVCH_W

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 W
Unit
W

In testing for 2020 to 2026.

High-voltage coolant heater requested power XC40R_REQ_CONS_HVCH_CCM_W

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 W
Unit
W

In testing for 2020 to 2026.

Interior temperature XC40R_INTERIOR_T

  • Service 22DID 9843
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45−60
Range
-60 to 144 °C
Unit
°C

In testing for 2020 to 2026.

Module current XC40R_MODULE_CURRENT

  • Service 22DID 1946
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2020 to 2026.

Motor hours since last service XC40R_MOTOR_HOURS_SINCE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2020 to 2026.

On-board charger module temperature XC40R_OBC_T

  • Service 22DID EE19
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2020 to 2026.

Outside heat exchanger outlet sensor pressure XC40R_OUTSIDE_HEAT_P

  • Service 22DID EE48
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Raw value

In testing for 2020 to 2026.

Outside heat exchanger outlet sensor temperature XC40R_OUTSIDE_HEAT_T

  • Service 22DID EE47
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Water cooled condenser outlet sensor temperature XC40R_WATER_COOLED_T

  • Service 22DID EE40
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2020 to 2026.

Movement

Air conditioning compressor module a speed XC40R_AC_COMP_MODULE_SPD

  • Service 22DID 032F
  • ModuleD016 → 1EC04E80
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2020 to 2026.

Electric rear axle drive motor speed XC40R_ERAD_MOTOR_SPD

  • Service 22DID 4A0E
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 rpm
Unit
rpm

In testing for 2020 to 2026.

Radiator cooling fan 1, requested speed XC40R_RADIATOR_COOLING_FAN_1

  • Service 22DID EE62
  • ModuleD016 → 1EC60E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2020 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2021. Supported for 2024.

Vehicle speed XC40R_VSS

  • Service 22DID F40D
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2021. Supported for 2024.

Tires

Front left wheel speed XC40R_FL_WHL_SPD

  • Service 22DID 2B06
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Front left wheel speed XC40R_FL_WHL_SPD_XC

  • Service 22DID 2B06
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Front right wheel speed XC40R_FR_WHL_SPD

  • Service 22DID 2B07
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Front right wheel speed XC40R_FR_WHL_SPD_XC

  • Service 22DID 2B07
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear left wheel speed XC40R_RL_WHL_SPD

  • Service 22DID 2B08
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear left wheel speed XC40R_RL_WHL_SPD_XC

  • Service 22DID 2B08
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear right wheel speed XC40R_RR_WHL_SPD

  • Service 22DID 2B09
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear right wheel speed XC40R_RR_WHL_SPD_XC

  • Service 22DID 2B09
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Transmission

Clutch pump duty XC40R_CLU_PMP_DUTY

  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Trips

Distance since last service XC40R_DIST_SINCE_SERVICE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Odometer XC40R_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 61BB
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer at last service XC40R_ODO_LAST_SERVICE

  • Service 22DID D906
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Total distance XC40R_DEM_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • ModuleD016 → 1EC70E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Total distance XC40R_TOT_DIST

  • Service 22DID DD01
  • ModuleD016 → 1EC6EE80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.