Volvo XC60

Parameters

The Volvo XC60 has 513 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

All-wheel drive coupling module voltage XC60_MECU_V

  • Service 22DID DD02
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 V
Unit
V

In testing for 1997, 2008 to 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

All-wheel drive coupling module voltage XC60_MECU_V

  • Service 22DID DD02
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 V
Unit
V

In testing for 1997, 2008 to 2017.

Alternator charge voltage request XC60_ALTERNATOR_CHG_V_REQ

  • Service 22DID 411D
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Auxiliary battery current XC60_AUXILIARY_BAT

  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Auxiliary battery temperature XC60_AUXILIARY_BAT_T

  • Service 22DID 40D3
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Auxiliary battery voltage XC60_AUXILIARY_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 417E
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Average static low range battery current XC60_AVG_STATIC_LOW_RANGE

  • Service 22DID 4025
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 mA
Unit
mA

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Battery charge balance, ah XC60_BAT_CHG_BALANCE_AH

  • Service 22DID 41A5
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Battery charge, amps XC60_BAT_CHG_AMPS

  • Service 22DID 4090
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511 to 3584 A
Unit
A

In testing for 1997, 2008 to 2017.

Battery current XC60_BAT_CURRENT

  • Service 22DID 4090
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−512
Range
-512 to 3583 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Battery operation time since battery monitoring sensor reset, days XC60_BAT_OPERATION_TIME

  • Service 22DID 4027
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Battery relay XC60_BAT_RELAY

  • Service 22DID D953
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Battery state of charge XC60_BAT_ST_CHG

  • Service 22DID 4028
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Battery state of charge XC60_BAT_ST_CHG_726

  • Service 22DID 4028
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1997, 2008 to 2017.

Battery temperature XC60_BAT_T

  • Service 22DID 4029
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Battery voltage XC60_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40+5
Range
0 to 1643 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Battery voltage XC60_BAT_V_726

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

In testing for 1997, 2008 to 2017.

Boost pressure after turbocharger XC60_BOOST_P_AFTER

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val131−0.053435
Range
-0.0534 to 500 kPa
Unit
kPa

In testing for 1997, 2008 to 2021.

Charger cable current XC60_CHARGER_CABLE

  • Service 22DID EE8D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−410
Range
-410 to 6143 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Charging socket lock XC60_CHG_SOCKET_LOCKED

  • Service 22DID EE8C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2012, 2015, 2020, 2024 to 2025. Supported for 1997, 2016 to 2019, 2021 to 2023, 2026.

Control module voltage XC60_CTRL_MODULE_V_MS_CAN

  • Service 22DID D904
  • Module784
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 1997, 2008 to 2017.

DC charger current XC60_DC_CHARGER_CURRENT

  • Service 22DID EE16
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

DC charger voltage XC60_DC_CHARGER_V

  • Service 22DID EE17
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode
3Not PSA

Confirmed for 2024. Supported for 2019, 2021.

Front camera voltage supply XC60_FRONT_CAMERA_V_SUP

  • Service 22DID 9969
  • Module764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 1997, 2008 to 2017.

High voltage battery current XC60_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery state of charge XC60_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 %
Unit
%

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery voltage XC60_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, average temperature XC60_HVBAT_AVG_T

  • Service 22DID 491B
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−50
Range
-50 to 605 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, coolant pump speed, actual XC60_HVBAT_CLT_PMP_SPD_ACT

  • Service 22DID 4867
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, coolant pump speed, requested XC60_HVBAT_CLT_PMP_SPD

  • Service 22DID 4866
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, high-voltage coolant heater fuse voltage XC60_HVBAT_HVCH_FUSE_V

  • Service 22DID 480A
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, IEM fuse voltage XC60_HVBAT_IEM_FUSE_V

  • Service 22DID 4808
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, IGM fuse voltage XC60_HVBAT_IGM_FUSE_V

  • Service 22DID 4809
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, inlet coolant temperature XC60_HVBAT_INLET_ECT

  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, max temperature XC60_HVBAT_MAX_T

  • Service 22DID 4945
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val100−50
Range
-50 to 605 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High voltage battery, OBC fuse voltage XC60_HVBAT_OBC_FUSE_V

  • Service 22DID 480B
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018 to 2019, 2021, 2023.

Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2024. Supported for 2019, 2021.

Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.98 V
Unit
V

Confirmed for 2024. Supported for 2019, 2021.

Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

Confirmed for 2024. Supported for 2019, 2021.

Main charger current XC60_MAIN_CHARGER_CURRENT

  • Service 22DID EE15
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Main charger voltage XC60_MAIN_CHARGER_V

  • Service 22DID EE1C
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Module voltage XC60_MODULE_V

  • Service 22DID D111
  • ModuleD016 → 1EC70E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Secondary battery charge time XC60_SECONDARY_BAT_CHG

  • Service 22DID EED3
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1997, 2008 to 2017.

Secondary battery needed charge time XC60_SECONDARY_BAT_NEEDED

  • Service 22DID EED5
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1997, 2008 to 2017.

Secondary battery relay XC60_SECONDARY_BAT_RELAY

  • Service 22DID 419C
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Secondary battery temperature XC60_SECONDARY_BAT_T_25_C

  • Service 22DID EED2
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Secondary battery voltage XC60_SECONDARY_BAT_V

  • Service 22DID 417E
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Secondary battery voltage average value XC60_SECONDARY_BAT_V_AVG

  • Service 22DID EED7
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Secondary battery voltage latest stored XC60_SECONDARY_BAT_V_LATEST

  • Service 22DID EED4
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Servo supply voltage XC60_SERVO_SUP_V

  • Service 22DID 413D
  • Module730
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Start/stop battery relay XC60_START_STOP_BAT_RELAY

  • Service 22DID EF51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Start/stop secondary battery relay XC60_START_STOP_SECONDARY

  • Service 22DID EF52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Supercharger clutch, requested position XC60_SUPERCHARGER_CLU_REQ

  • Service 22DID EE84
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission control module supply voltage XC60_MECU_SUP_V

  • Service 22DID DD02
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 V
Unit
V

In testing for 1997, 2008 to 2021.

Voltage supply XC60_V_SUP

  • Service 22DID D901
  • Module737
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 1997, 2008 to 2017.

Voltage supply XC60_V_SUP_764

  • Service 22DID D112
  • Module764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 1997, 2008 to 2017.

Voltage supply XC60_V_SUP_MS_CAN

  • Service 22DID D111
  • Module791
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Voltage/power sensitive loads connected XC60_V_POWER_SENSITIVE

  • Service 22DID EEA2
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Internal

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2019, 2021.

Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2019, 2021.

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2019, 2021.

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024. Supported for 2019, 2021.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012, 2017, 2020 to 2021, 2024 to 2026. Supported for 1997, 2015 to 2016, 2018 to 2019, 2022 to 2023.

Auxiliary water pump duty cycle XC60_AUXILIARY_WATER_PMP

  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Evaporator temperature XC60_EVAPORATOR_T

  • Service 22DID 984F
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Evaporator temperature v.2 XC60_EVAPORATOR_T_V_2

  • Service 22DID 9820
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×165
Range
-409 to 406 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Fuel-operated heater, inlet water temperature XC60_FOH_INLET_WATER_T

  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Fuel-operated heater, outlet water temperature XC60_FOH_OUTLET_WATER_T

  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Heater core temperature XC60_HEAT_EXCHANGER_T

  • Service 22DID 9850
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Heater core temperature, variant 2 XC60_HEAT_EXCHANGER_T_V_2

  • Service 22DID 4337
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×165
Range
-409 to 406 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater coolant inlet temperature XC60_HVCH_CLT_INLET_T

  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater coolant outlet temperature XC60_HVCH_CLT_OUTLET_T

  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater current consumption XC60_HVCH_CURRENT_CONS

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater power consumption XC60_HVCH_POWER_CONS

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 W
Unit
W

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater required power consumption XC60_HVCH_REQUIRED_POWER

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 W
Unit
W

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Interior temperature XC60_INTERIOR_T

  • Service 22DID 9843
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45−60
Range
-60 to 144 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2017, 2020, 2022, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021, 2023 to 2024, 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2015, 2020, 2024 to 2025. Supported for 1997, 2016 to 2019, 2021 to 2023, 2026.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2020, 2024 to 2025. Supported for 2016, 2021 to 2023, 2026.

Brake pedal position XC60_BRAKE_PEDAL_POS

  • Service 22DID E504
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Brake pressure XC60_BRAKE_P

  • Service 22DID 2B0D
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3
Range
0 to 21845 bar
Unit
bar

In testing for 1997, 2008 to 2017.

Brake pressure sensor offset XC60_BRAKE_P_SENS_OFFSET

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1600
Range
0 to 40.95 bar
Unit
bar

In testing for 1997, 2008 to 2017.

Brake switch XC60_BRAKE_SWITCH

  • Service 22DID D943
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 1997, 2008 to 2021.

Front left brake disc temperature XC60_FL_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Front left brake disc temperature, calculated XC60_FL_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Front right brake disc temperature XC60_FR_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Front right brake disc temperature, calculated XC60_FR_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Left parking brake pad XC60_LEFT_PARKING_BRAKE

  • Service 22DID 2B1A
  • Module756
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Park brake switch XC60_PARK_BRAKE_SWITCH

  • Service 22DID 2B14
  • Module756
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Parking brake dynamic use count XC60_PARKING_BRAKE_CNT_DYNAMIC

  • Service 22DID 2B21
  • Module756
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Parking brake normal 0 /maintenance 32 XC60_PARKING_BRAKE_NORMAL_0_32

  • Service 22DID 2B24
  • Module756
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Parking brake static use count XC60_PARKING_BRAKE_CNT

  • Service 22DID 2B20
  • Module756
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Rear left brake disc temperature XC60_RL_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Rear left brake disc temperature, calculated XC60_RL_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Rear right brake disc temperature XC60_RR_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Rear right brake disc temperature, calculated XC60_RR_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2024 to 2025. Supported for 2016 to 2019, 2021 to 2023, 2026.

Right parking brake pad XC60_RIGHT_PARKING_BRAKE

  • Service 22DID 2B1A
  • Module756
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Start/stop brake booster pressure XC60_START_STOP_BRAKE_P

  • Service 22DID EF44
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 1997, 2008 to 2021.

Doors

Drivers door rear mirror x-axis XC60_DRIVERS_DOOR_REAR_X

  • Service 22DID A4A7
  • Module740
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 1997, 2008 to 2017.

Drivers door rear mirror y-axis XC60_DRIVERS_DOOR_REAR_Y

  • Service 22DID A4A8
  • Module740
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 1997, 2008 to 2017.

Passenger door rear mirror x-axis XC60_PASSENGER_DOOR_REAR_MIRROR_X

  • Service 22DID A4A8
  • Module741
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 1997, 2008 to 2017.

Passenger door rear mirror x-axis XC60_PASSENGER_DOOR_REAR_X

  • Service 22DID A4A7
  • Module741
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 1997, 2008 to 2017.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2012, 2015, 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2016, 2018 to 2019, 2021, 2023.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2020, 2025. Supported for 2016, 2018 to 2019, 2021 to 2024, 2026.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2017, 2020, 2022, 2024 to 2025. Supported for 1997, 2015 to 2016, 2018 to 2019, 2021, 2023, 2026.

Engine

- pedal position sensor XC60_PEDAL_POS_SENS

  • Service 22DID 2B35
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val25
Range
0 to 2621 mm
Unit
mm

In testing for 1997, 2008 to 2017.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 2012, 2016, 2018 to 2019, 2021, 2023.

Accelerator pedal position XC60_M3_APP_ECM

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018, 2023.

Adaptive cruise target vehicle XC60_ACC_TARGETVEHICLE

  • Service 22DID DA12
  • Module720
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Adaptive cruise time gap XC60_ACC_TIMEGAP

  • Service 22DID DA11
  • Module720
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2+0.5
Range
0 to 128 s
Unit
s

In testing for 1997, 2008 to 2017.

Air conditioning pressure XC60_AC_P

  • Service 22DID D900
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

In testing for 1997, 2008 to 2021.

Air conditioning relay XC60_AC_RELAY

  • Service 22DID D909
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Air distribution damper motor wanted position XC60_AIR_DISTRIBUTION

  • Service 22DID D904
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Air distribution damper motor, actual position XC60_AIR_DISTRIBUTION_ACT

  • Service 22DID D909
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2012, 2015, 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2016, 2018 to 2019, 2021, 2023.

Air flow/cycle, mg/s XC60_AIR_FLOW_CYCLE_MG_S

  • Service 22DID D916
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 1997, 2008 to 2021.

Air mass, desired XC60_AIR_MASS_DES

  • Service 22DID D91F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 1997, 2008 to 2021.

Air quality sensor status XC60_AIR_QUALITY_SENS

  • Service 22DID DCF9
  • Module733
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

All-wheel drive coupling current XC60_HALDEX_CURRENT

  • Service 22DID 1945
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2017.

All-wheel drive coupling current XC60_HALDEX_CURRENT_795

  • Service 22DID 1946
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2017.

All-wheel drive coupling module temperature sensor 1 XC60_HALDEX_ECU_T_SENS_1

  • Service 22DID D116
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1997, 2008 to 2017.

All-wheel drive coupling module temperature sensor 2 XC60_HALDEX_ECU_T_SENS_2

  • Service 22DID D900
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1997, 2008 to 2017.

All-wheel drive coupling oil temperature XC60_HALDEX_OIL_T

  • Service 22DID FD04
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 1997, 2008 to 2017.

All-wheel drive coupling pressure XC60_HALDEX_P

  • Service 22DID 1944
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 1997, 2008 to 2017.

All-wheel drive coupling rear axle torque XC60_HALDEX_REAR_AXLE_TQ

  • Service 22DID D930
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1997, 2008 to 2017.

All-wheel drive coupling rear axle torque, requested XC60_HALDEX_REAR_AXLE_TQ_REQ

  • Service 22DID D953
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1997, 2008 to 2017.

Alternator control mode XC60_ALTERNATOR_CTRL_MODE

  • Service 22DID 40D1
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Alternator, amps XC60_ALTERNATOR_AMPS

  • Service 22DID D924
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 1997, 2008 to 2021.

Automatic alignment offset XC60_AUTOMATIC_ALIGNMENT

  • Service 22DID A220
  • Module764
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 1997, 2008 to 2017.

Average charging time left XC60_AVG_CHG_TIME_LEFT

  • Service 22DID EEB6
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021, 2023.

Battery management sensor reliable XC60_BAT_MANAGEMENT_SENS

  • Service 22DID 41A7
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Bonnet closed XC60_BONNET_CLOSED

  • Service 22DID C154
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Boost air pressure after turbocharger XC60_BOOST_AIR_P_AFTER

  • Service 22DID 033E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 kPa
Unit
kPa

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Boost air temperature XC60_BOOST_AIR_T

  • Service 22DID 0341
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Boost air temperature XC60_BOOST_AIR_T_7E0

  • Service 22DID 0341
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Boost pressure XC60_BOOST_P

  • Service 22DID D941
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 1997, 2008 to 2021.

Boost pressure, desired value XC60_BOOST_P_DES

  • Service 22DID D9E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 1997, 2008 to 2021.

Boot lid sensor XC60_BOOT_LID_SENS

  • Service 22DID C150
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val64
Range
0 to 3.98
Unit
Number

In testing for 1997, 2008 to 2017.

Burning time, hours XC60_BURNING_TIME_HOURS

  • Service 22DID 9A0B
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1997, 2008 to 2017.

Burning time, minutes XC60_BURNING_TIME_MINUTES

  • Service 22DID 9A0B
  • Module7E3
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2015, 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2016, 2018 to 2019, 2021, 2023.

Calculated load XC60_CALC_LOAD

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020, 2022, 2024 to 2026. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021, 2023.

Central lock XC60_CENTRAL_LOCK

  • Service 22DID C259
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 1997, 2008 to 2017.

Charging XC60_CHG_MS_CAN

  • Service 22DID D901
  • Module791
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−1
Range
-1 to 254
Unit
Number

In testing for 1997, 2008 to 2017.

Charging state XC60_CHG_ST

  • Service 22DID EE1D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Cold zone count XC60_CEM_COLD_ZONE

  • Service 22DID D9FE
  • Module733
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Combustion air fan XC60_COMBUSTION_AIR_FAN

  • Service 22DID 9A06
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2022. Supported for 1997, 2015, 2019, 2021.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2012, 2020, 2022, 2024 to 2026. Supported for 2016, 2018 to 2019, 2021, 2023.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2012, 2016, 2018 to 2019, 2021, 2023.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 2018 to 2019, 2021, 2023.

Control module power supply XC60_CTRL_MODULE_POWER

  • Service 22DID D111
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Control module temperature XC60_CTRL_MODULE_T

  • Service 22DID D9B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Coolant pump relay XC60_CLT_PMP_RELAY

  • Service 22DID D95B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Counter XC60_CNT_MS_CAN

  • Service 22DID 9A0D
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Cylinder 1 misfire XC60_MIS_1

  • Service 22DID F6A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 1 misfire average XC60_MIS_AVG_1

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 2 misfire XC60_MIS_2

  • Service 22DID F6A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 2 misfire average XC60_MIS_AVG_2

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 3 misfire XC60_MIS_3

  • Service 22DID F6A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 3 misfire average XC60_MIS_AVG_3

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 4 misfire XC60_MIS_4

  • Service 22DID F6A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 4 misfire average XC60_MIS_AVG_4

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 5 misfire average XC60_MIS_AVG_5

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 6 misfire average XC60_MIS_AVG_6

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 7 misfire average XC60_MIS_AVG_7

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Cylinder 8 misfire average XC60_MIS_AVG_8

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Defroster damper motor wanted position XC60_DEFROSTER_DAMPER

  • Service 22DID D900
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Defroster damper motor, actual position XC60_DEFROSTER_DAMPER_ACT

  • Service 22DID D905
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Diesel particulate filter additive pump XC60_M3_ADM_ADDITIVE_PMP

  • Service 22DID D904
  • Module7C0
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1997, 2008 to 2017.

Diesel particulate filter pressure XC60_DPF_P

  • Service 22DID DAC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1997, 2008 to 2021.

Diesel particulate filter soot XC60_DPF_SOOT

  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 1997, 2008 to 2021.

Diesel particulate filter temperature XC60_DPF_T

  • Service 22DID D9F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Dipped beam XC60_DIPPED_BEAM

  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Display illumination intensity XC60_LCD_ILUMINATION

  • Service 22DID DB01
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1997, 2008 to 2017.

Display temperature XC60_DISPLAY_T_MS_CAN

  • Service 22DID D906
  • Module784
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 1997, 2008 to 2017.

Downtime XC60_DOWNTIME

  • Service 22DID EED6
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 1997, 2008 to 2017.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017, 2022. Supported for 1997, 2015, 2019, 2021.

Electric rear axle drive calculated torque XC60_ERAD_CALC_TQ

  • Service 22DID EF12
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4−8188
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012, 2015, 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2016, 2018 to 2019, 2021, 2023.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018.

Engine oil pressure XC60_EOP

  • Service 22DID EF4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 1997, 2008 to 2021.

Engine oil temperature XC60_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D9DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021, 2023.

Engine time since last service XC60_ENG_TIME_SINCE

  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1997, 2008 to 2017.

Engine torque XC60_ENG_TQ

  • Service 22DID DA89
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−512
Range
-512 to 6041 N·m
Unit
N·m

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Evap system vapor pressure (wide) EVAP_VP_WIDESAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 54
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32767 to 32768 kPa
Unit
kPa

Confirmed for 2024 to 2026. Supported for 2021, 2023.

Evaporator temperature XC60_EVAPORATOR_T_MS_CAN

  • Service 22DID D998
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−100
Range
-100 to 923 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Exhaust gas recirculation bypass valve XC60_EGR_BYPASS_VLV

  • Service 22DID EE7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1997, 2008 to 2021.

Exhaust gas recirculation cooler bypass actuator position XC60_EGR_COOLER_BYPASS

  • Service 22DID DAD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Exhaust gas recirculation valve position sensor XC60_EGR_VLV_POS_SENS

  • Service 22DID DAAD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 1997, 2008 to 2021.

Exhaust gas recirculation valve, commanded position XC60_EGR_VLV_CMD_POS

  • Service 22DID DC01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 1997, 2008 to 2021.

Exhaust gas recirculation valve, commanded position II XC60_EGR_VLV_CMD_POS_II

  • Service 22DID D96D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Fan XC60_FAN

  • Service 22DID DC02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Front axle sensor XC60_FRONT_AXLE_SENS

  • Service 22DID 3B71
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.37 V
Unit
V

In testing for 1997, 2008 to 2017.

Front oxygen sensor heating XC60_FRONT_OXYGEN_SENS

  • Service 22DID DA59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 ms
Unit
ms

In testing for 1997, 2008 to 2021.

Fuel injection timing FUEL_TIMINGSAE J1979Confirmed

Start of main fuel injection relative to Top Dead Center (TDC). Positive degrees indicate before TDC, negative degrees indicate after TDC.

  • Service 01PID 5D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−38665
Range
-210 to 301.992 °
Unit
°

Confirmed for 2017. Supported for 2019, 2021.

Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is absolute (referenced to vacuum). Meant for diesel and gasoline direct-injection systems, whose pressures exceed the range of PIDs 0A and 22.

  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 2018 to 2019, 2021, 2023.

Glow plug pulse ratio XC60_GLOW_PLUG_RAT_MS_CAN

  • Service 22DID 9A04
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2017.

Glow plugs XC60_GLOW_PLUGS

  • Service 22DID D9A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Grill shutter open XC60_GRILL_SHUTTER_OPEN

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

High beam XC60_HIGH_BEAM

  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

High voltage system current XC60_HIGH_V_SYSTEM

  • Service 22DID EF13
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−250
Range
-250 to 260 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Ignition angle before top dead center XC60_IGN_ANG_BTDC

  • Service 22DID F40E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5
Unit
Number

In testing for 1997, 2008 to 2021.

In car temperature XC60_CAR_T

  • Service 22DID DD04
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

In car temperature XC60_CAR_T_MS_CAN_7E3

  • Service 22DID DD04
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

In-car temperature XC60_CAR_T_720

  • Service 22DID DD04
  • Module720
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

In-car temperature XC60_CAR_T_MS_CAN

  • Service 22DID 9A1B
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−100
Range
-100 to 923 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Infotainment ring optical fiber test XC60_MOST_OPTICAL_FIBRE

  • Service 22DID 831F
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Input torque calculated XC60_INPUT_TQ_CALC

  • Service 22DID D962
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8−16376
Range
-16376 to 507904 N·m
Unit
N·m

In testing for 1997, 2008 to 2017.

Input torque, requested XC60_INPUT_TQ_REQ

  • Service 22DID D956
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8−16376
Range
-16376 to 507904 N·m
Unit
N·m

In testing for 1997, 2008 to 2017.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021, 2023.

Intake air temperature, manifold sensor XC60_TMAP_IAT

  • Service 22DID D9AB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.14
Range
-3549 to 3003 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017, 2020, 2022, 2024 to 2026. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021, 2023.

Lateral angle XC60_LATERAL_ANG

  • Service 22DID 2B0C
  • Module760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °
Unit
°

In testing for 1997, 2008 to 2017.

Leading A/T XC60_LEADING_T

  • Service 22DID 1E2F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1997, 2008 to 2021.

Left seat heater XC60_LEFT_SEAT_HEATER_MS

  • Service 22DID 9A21
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Left temperature damper motor wanted position XC60_LEFT_T_DAMPER_MOTOR

  • Service 22DID D902
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Left temperature damper motor, actual position XC60_LEFT_T_DAMPER_MOTOR_ACT

  • Service 22DID D907
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Load XC60_LOAD

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2051
Range
0 to 25700 %
Unit
%

In testing for 1997, 2008 to 2021.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2012, 2016, 2018 to 2019, 2021, 2023.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018, 2021, 2023.

M3 APP, CAN XC60_M3_APP_CAN

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

M3 diff.press. XC60_M3_DIFF_PRESS

  • Service 22DID D9F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1997, 2008 to 2021.

M3 DPF soot XC60_M3_DPF_SOOT

  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 g
Unit
g

In testing for 1997, 2008 to 2021.

M3 EGR DC XC60_M3_EGR_DC

  • Service 22DID D96C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

M3 IAT, butterfly XC60_M3_IAT_BUTTERFLY

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2021.

M3 IAT, MAF XC60_M3_IAT_MAF

  • Service 22DID D91C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Misfire catalytic damage total - petrol XC60_MIS_CATALYTIC_DAMAGE

  • Service 22DID DA03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2021.

Module current XC60_MODULE_CURRENT

  • Service 22DID 1946
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Months since last service XC60_MONTHS_SINCE_SERVICE

  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val120
Range
0 to 546
Unit
Number

In testing for 1997, 2008 to 2017.

MOST lock XC60_MOST_LOCK_MS_CAN

  • Service 22DID DB16
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

MOST network number of modules XC60_MOST_NETWORK_NUM

  • Service 22DID 8335
  • Module784
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Navigation altitude XC60_SENSUS_CONNECT_GPS

  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val180
Range
0 to 364 °
Unit
°

In testing for 1997, 2008 to 2017.

Navigation fix XC60_SENSUS_CONNECT_GPS_FIX_MS

  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1997, 2008 to 2017.

Navigation heading XC60_SENSUS_CONNECT_GPS_HEADING

  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 1997, 2008 to 2017.

Navigation number of satellites XC60_SENSUS_CONNECT_GPS_NUM

  • Service 22DID 8035
  • Module784
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

On-board charger module temperature XC60_OBC_T

  • Service 22DID EE19
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Operating state XC60_OP_ST_MS_CAN

  • Service 22DID 9A08
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Outdoor temperature, BCM XC60_OUTDOOR_T_BCM

  • Service 22DID DD05
  • Module760
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Parking heater counter XC60_PARKING_HEATER_CNT

  • Service 22DID 9A0E
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Parking lights XC60_PARKING_LIGHTS

  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Passenger airbag activated XC60_PASSENGER_AIRBAG_ACTIVATED

  • Service 22DID 5B29
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Passenger airbag cutoff switch XC60_PASSENGER_AIRBAG

  • Service 22DID 5B28
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 1997, 2008 to 2017.

Passenger airbag OFF lamp XC60_PASSENGER_AIRBAG_OFF

  • Service 22DID 61A5
  • Module737
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96
Unit
Number

In testing for 1997, 2008 to 2017.

Power mode XC60_POWER_MODE

  • Service 22DID DD06
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−192
Range
-192 to 63
Unit
Number

In testing for 1997, 2008 to 2017.

Power mode XC60_POWER_MODE_MS_CAN

  • Service 22DID DD07
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−99
Range
-99 to 156
Unit
Number

In testing for 1997, 2008 to 2017.

Power mode XC60_POWER_MODE_MS_CAN_7E3

  • Service 22DID DD06
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Quiescent current average XC60_QUIESCENT_CURRENT

  • Service 22DID 4025
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767 mA
Unit
mA

In testing for 1997, 2008 to 2017.

Rear axle sensor XC60_REAR_AXLE_SENS

  • Service 22DID 3B73
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.37 V
Unit
V

In testing for 1997, 2008 to 2017.

Rear defroster automatic XC60_REAR_DEFROSTER

  • Service 22DID D918
  • Module733
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Rear left seat heater XC60_RL_SEAT_HEATER_MS

  • Service 22DID 9A23
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Rear oxygen sensor heating XC60_REAR_OXYGEN_SENS

  • Service 22DID DB77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 ms
Unit
ms

In testing for 1997, 2008 to 2021.

Rear right seat heater XC60_RR_SEAT_HEATER_MS

  • Service 22DID 9A24
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Recirculation damper motor wanted position XC60_RECIRCULATION_DAMPER

  • Service 22DID D901
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Recirculation damper motor, actual position XC60_RECIRCULATION_DAMPER_ACT

  • Service 22DID D906
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Remote key XC60_REMOTE_KEY

  • Service 22DID 412D
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Right seat heater XC60_RIGHT_SEAT_HEATER_MS

  • Service 22DID 9A22
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Right temperature damper motor wanted position XC60_RIGHT_T_DAMPER_MOTOR

  • Service 22DID D903
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Right temperature damper motor, actual position XC60_RIGHT_T_DAMPER_MOTOR_ACT

  • Service 22DID D908
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2017.

Running time, hours XC60_RUNNING_TIME_HOURS

  • Service 22DID 9A0C
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1997, 2008 to 2017.

Running time, minutes XC60_RUNNING_TIME_MINUTES

  • Service 22DID 9A0C
  • Module7E3
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Seat buckle driver locked XC60_SEAT_BUCKLE_DRIVER

  • Service 22DID 5B19
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 1997, 2008 to 2017.

Seat buckle passenger locked XC60_SEAT_BUCKLE

  • Service 22DID 5B1A
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 1997, 2008 to 2017.

Seat buckle rear center locked XC60_SEAT_BUCKLE_REAR

  • Service 22DID 5B47
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Seat buckle rear left locked XC60_SEAT_BUCKLE_RL

  • Service 22DID 5B46
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Seat buckle rear right locked XC60_SEAT_BUCKLE_RR

  • Service 22DID 5B48
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Servo control module temperature XC60_SERVO_CTRL_MODULE_T

  • Service 22DID D11C
  • Module730
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Servo pump engine power consumption XC60_SERVO_PMP_ENG_POWER

  • Service 22DID 4139
  • Module730
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 A
Unit
A

In testing for 1997, 2008 to 2017.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2012, 2020, 2022, 2024 to 2026. Supported for 2016, 2018 to 2019, 2021, 2023.

Slave A/T XC60_SLAVE_T

  • Service 22DID 1E1B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1997, 2008 to 2021.

SLC1 current XC60_SLC1_CURRENT

  • Service 22DID D90C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

SLC2 current XC60_SLC2_CURRENT

  • Service 22DID D90F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

SLC3 current XC60_SLC3_CURRENT

  • Service 22DID D910
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Starter relay XC60_STARTER_RELAY

  • Service 22DID D950
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Starter relay 1 XC60_STARTER_RELAY_1

  • Service 22DID DA12
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Starter relay 2 XC60_STARTER_RELAY_2

  • Service 22DID EEEB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Steering angle, actual value XC60_STEER_ANG_ACT

  • Service 22DID 3302
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 1997, 2008 to 2017.

Steering shaft torque XC60_STEER_SHFT_TQ

  • Service 22DID 330C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

In testing for 1997, 2008 to 2017.

Supplementary heater counter XC60_SUPPLEMENTARY_HEATER

  • Service 22DID 9A0F
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

System relay XC60_SYSTEM_RELAY

  • Service 22DID D94F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Tailgate closing motor XC60_TAILGATE_CLOSING

  • Service 22DID D908
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Tailgate hall sensor signal XC60_TAILGATE_HALL_SENS

  • Service 22DID D904
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Tailgate handle button XC60_TAILGATE_HANDLE

  • Service 22DID D900
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Tailgate motor protection XC60_TAILGATE_MOTOR

  • Service 22DID EE04
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Tailgate opening motor XC60_TAILGATE_OPENING

  • Service 22DID D907
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Tailgate opening position XC60_TAILGATE_OPENING_POS

  • Service 22DID D909
  • Module775
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Tailgate power supply XC60_TAILGATE_POWER_SUP

  • Service 22DID D111
  • Module775
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Tailgate switch 1-2 XC60_TAILGATE_SWITCH_1_2

  • Service 22DID D901
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2017.

Temperature left setting XC60_T_LEFT_SETTING_MS

  • Service 22DID D930
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Temperature right setting XC60_T_RIGHT_SETTING_MS

  • Service 22DID D931
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Throttle absolute position XC60_THROTTLE_ABS_POS

Pelican can show this parameter as the throttle position.

  • Service 22DID F411
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

Time since engine start XC60_TIME_SINCE_ENG_START

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1997, 2008 to 2021.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2012, 2016, 2018 to 2019, 2021, 2023.

Torque converter lock-up solenoid XC60_LOCK_UP_SOLENOID_SLU_7E1

  • Service 22DID DA4C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Torque converter lock-up solenoid current XC60_LOCK_UP_SOLENOID_SLU_CURRENT

  • Service 22DID 1E47
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Torque converter lock-up solenoid current, requested XC60_LOCK_UP_SOLENOID_SLU

  • Service 22DID 1E41
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Torque converter lock-up solenoid, requested XC60_LOCK_UP_SOLENOID_SLU_REQ

  • Service 22DID DA4B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Total engine running time at last service XC60_TOT_ENG_RUNNING_TIME

  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1997, 2008 to 2017.

Total months at last service XC60_TOT_MONTHS_LAST

  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×6
Range
0 to 393210
Unit
Raw value

In testing for 1997, 2008 to 2017.

Traction control switch indicator XC60_DTSC_SWITCH

  • Service 22DID 2B05
  • Module760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val64−1
Range
-1 to 2.98
Unit
Number

In testing for 1997, 2008 to 2017.

Transmission fixed lock-up XC60_FIXED_LOCK_UP

  • Service 22DID 1E24
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission kickdown XC60_KICKDOWN

  • Service 22DID DCE4
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission line pressure solenoid current XC60_LINEAR_P_SOLENOID_SLT

  • Service 22DID 1E40
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission line pressure solenoid current XC60_LINEAR_P_SOLENOID_SLT_CURRENT

  • Service 22DID DA4A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission line pressure solenoid current, requested XC60_LINEAR_P_SOLENOID

  • Service 22DID 1E1E
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission line pressure solenoid current, requested XC60_LINEAR_P_SOLENOID_SLT_REQ

  • Service 22DID DA49
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SL1 current XC60_LINEAR_P_SOLENOID_SL1

  • Service 22DID DA4E
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SL1, requested, current XC60_LINEAR_P_SOLENOID_SL1_REQ

  • Service 22DID DA4D
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SL2 current XC60_LINEAR_P_SOLENOID_SL2

  • Service 22DID DA50
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SL2, requested, current XC60_LINEAR_P_SOLENOID_SL2_REQ

  • Service 22DID DA4F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SL3 current XC60_LINEAR_P_SOLENOID_SL3

  • Service 22DID DA52
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SL3, requested, current XC60_LINEAR_P_SOLENOID_SL3_REQ

  • Service 22DID DA51
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLB1, requested, current XC60_LINEAR_P_SOLENOID_SLB1_REQ

  • Service 22DID 1E45
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLC1 current XC60_LINEAR_P_SOLENOID_SLC1

  • Service 22DID 1E48
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLC1, requested, current XC60_LINEAR_P_SOLENOID_SLC1_REQ

  • Service 22DID 1E42
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLC2 current XC60_LINEAR_P_SOLENOID_SLC2

  • Service 22DID 1E49
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLC2, requested, current XC60_LINEAR_P_SOLENOID_SLC2_REQ

  • Service 22DID 1E43
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLC3 current XC60_LINEAR_P_SOLENOID_SLC3

  • Service 22DID 1E4A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission linear pressure solenoid SLC3, requested, current XC60_LINEAR_P_SOLENOID_SLC3_REQ

  • Service 22DID 1E44
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Transmission lock-up function XC60_LOCK_UP_FUNCTION

  • Service 22DID DA3C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3−0.333333
Range
-0.333 to 84.66
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission selector XC60_SELECTOR

  • Service 22DID DCEA
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission solenoid S1 status XC60_SOLENOID_S1_STAT

  • Service 22DID DD89
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission solenoid S2 status XC60_SOLENOID_S2_STAT

  • Service 22DID DD8A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission start lock - start approved XC60_START_LOCK_START

  • Service 22DID DF08
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission torque XC60_TQ

  • Service 22DID DD8D
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1997, 2008 to 2021.

Transmission torque limiting XC60_TQ_LIMITING

  • Service 22DID DCF0
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 N·m
Unit
N·m

In testing for 1997, 2008 to 2021.

Trip 1 XC60_TRIP_1

  • Service 22DID D936
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 1997, 2008 to 2017.

Trip 2 XC60_TRIP_2

  • Service 22DID D937
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 1997, 2008 to 2017.

Turbo bypass valve opened XC60_TURBO_BYPASS_VLV

  • Service 22DID D9EE
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Turbo control valve wastegate XC60_TURBO_CTRL_VLV_WASTEGATE

  • Service 22DID DC10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1008191
Range
0 to 800 %
Unit
%

In testing for 1997, 2008 to 2021.

Turbo control valve, bypass or variable nozzle XC60_TURBO_CTRL_VLV

  • Service 22DID DC00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1008191
Range
0 to 800 %
Unit
%

In testing for 1997, 2008 to 2021.

Twilight sensor XC60_TWILIGHT_SENS

  • Service 22DID 412A
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1997, 2008 to 2017.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018 to 2019, 2021, 2023.

Wastegate position XC60_WASTEGATE_POS

  • Service 22DID DC80
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Water temperature XC60_WATER_T_MS_CAN

  • Service 22DID F405
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1997, 2008 to 2017.

Yaw rate sensor offset XC60_YAW_RATE_SENS_OFFSET

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val3500
Range
0 to 18.72
Unit
Raw value

In testing for 1997, 2008 to 2017.

Yaw rate signal XC60_YAW_RATE_SIG

  • Service 22DID 2B0B
  • Module760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

In testing for 1997, 2008 to 2017.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2025. Supported for 1997, 2012, 2015 to 2016, 2018 to 2019, 2021 to 2024, 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2012, 2020, 2022, 2024 to 2026. Supported for 2016, 2018 to 2019, 2021.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2015. Supported for 1997.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2025. Supported for 2012, 2016, 2018 to 2024, 2026.

SHRTFT associated with O2S12 SHRTFT12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2025. Supported for 2012, 2016, 2018 to 2024, 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2012, 2020, 2022, 2024 to 2026. Supported for 2016, 2018 to 2019, 2021.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2015. Supported for 1997.

Fuel

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2022, 2024 to 2026. Supported for 2017, 2019 to 2021, 2023.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

Fuel filter heater XC60_FUEL_FLT_HEATER

  • Service 22DID DC14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Fuel filter heater XC60_FUEL_FLT_HEATER_7E0

  • Service 22DID DB35
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Fuel heater fan adjustment XC60_FUEL_HEATER_FAN_ADJ

  • Service 22DID 9A03
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1997, 2008 to 2017.

Fuel level 1 of 2 XC60_DIM_FLI_1_2

  • Service 22DID 61D1
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level 2 of 2 ejector side saddle tank XC60_DIM_FLI_2_2_EJECTOR

  • Service 22DID 61D0
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level damped XC60_DIM_FLI_DAMPED

  • Service 22DID EE11
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level damped XC60_FLI_DAMPED

  • Service 22DID EE12
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 L
Unit
L

In testing for 1997, 2008 to 2017.

Fuel level input XC60_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1997, 2008 to 2021.

Fuel level sensor XC60_FLI_SENS

  • Service 22DID 4117
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10020459
Range
0 to 320 V
Unit
V

In testing for 1997, 2008 to 2017.

Fuel level sensor ejector side saddle tank XC60_FLI_SENS_EJECTOR

  • Service 22DID 4118
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10020459
Range
0 to 320 V
Unit
V

In testing for 1997, 2008 to 2017.

Fuel pressure XC60_FUEL_P

  • Service 22DID F423
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500
Unit
Raw value

In testing for 1997, 2008 to 2021.

Fuel pressure nominal value XC60_FUEL_P_NOMINAL

  • Service 22DID D9FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500
Unit
Raw value

In testing for 1997, 2008 to 2021.

Fuel pressure regulator valve current XC60_FUEL_P_REGULATOR_VLV

  • Service 22DID D9EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1997, 2008 to 2021.

Fuel pump low pressure side duty cycle XC60_FUEL_PMP_LOW_P_SIDE

  • Service 22DID EF59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2012, 2020, 2022, 2024 to 2025. Supported for 2016, 2018 to 2019, 2021, 2023, 2026.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2012, 2020, 2022, 2024 to 2025. Supported for 2016, 2018 to 2019, 2021, 2023, 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2015, 2020, 2022, 2024 to 2026. Supported for 1997, 2016 to 2019, 2021, 2023.

Fuel temperature XC60_FUEL_T

  • Service 22DID D99C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Fuel volume control valve XC60_FUEL_VOLUME_CTRL_VLV

  • Service 22DID DAD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Fuel volume control valve XC60_FUEL_VOLUME_CTRL_VLV_7E0

  • Service 22DID DC13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 1997, 2008 to 2021.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2020, 2022, 2024 to 2025. Supported for 2019, 2021.

Lights

Brake light switch XC60_BRAKE_LIGHT_SWITCH

  • Service 22DID 2B00
  • Module760
  • Every250 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1997, 2008 to 2017.

Movement

Accelerator pedal position XC60_ACCEL_PEDAL_POS

  • Service 22DID DD8E
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 1997, 2008 to 2021.

Adaptive cruise set speed XC60_ACC_SETSPEED

  • Service 22DID DA10
  • Module720
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Cabin fan speed, requested XC60_CABIN_FAN_SPD_REQ_MS

  • Service 22DID D950
  • Module733
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 %
Unit
%

In testing for 1997, 2008 to 2017.

Driven shaft speed XC60_DRIVEN_SHFT_SPD

  • Service 22DID DA38
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Indirect tire pressure monitoring high speed calibration XC60_ITPMS_HIGH_SPD

  • Service 22DID FDC6
  • Module760
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1997, 2008 to 2017.

Indirect tire pressure monitoring low speed calibration XC60_ITPMS_LOW_SPD

  • Service 22DID FDC6
  • Module760
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1997, 2008 to 2017.

Lateral acceleration sensor offset XC60_LATERAL

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val113000
Range
0 to 0.579 m/s²
Unit
m/s²

In testing for 1997, 2008 to 2017.

Lateral acceleration sensor stored offset XC60_LATERAL_ACCELEROMETER

  • Service 22DID EE04
  • Module760
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1113000
Range
0 to 0.0588 m/s²
Unit
m/s²

In testing for 1997, 2008 to 2017.

Servo pump speed XC60_SERVO_PMP_SPD

  • Service 22DID 413C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 1997, 2008 to 2017.

Servo pump speed, desired value XC60_SERVO_PMP_SPD_DES

  • Service 22DID 413A
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 1997, 2008 to 2017.

Traffic sign speed limit XC60_TSI_SPD

  • Service 22DID DA18
  • Module720
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×5
Range
0 to 327675 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2012, 2015, 2020, 2022, 2024 to 2026. Supported for 1997, 2016 to 2019, 2021, 2023.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2020, 2022, 2024 to 2026. Supported for 1997, 2012, 2015 to 2019, 2021, 2023.

Tires

Front left wheel speed XC60_FL_WHL_SPD

  • Service 22DID 2B06
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Front left wheel speed XC60_FL_WHL_SPD_760

  • Service 22DID 2B06
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Front left wheel speed XC60_FL_WHL_SPD_795

  • Service 22DID 2B06
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Front right wheel speed XC60_FR_WHL_SPD

  • Service 22DID 2B07
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Front right wheel speed XC60_FR_WHL_SPD_760

  • Service 22DID 2B07
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Front right wheel speed XC60_FR_WHL_SPD_795

  • Service 22DID 2B07
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Rear left wheel speed XC60_RL_WHL_SPD

  • Service 22DID 2B08
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Rear left wheel speed XC60_RL_WHL_SPD_760

  • Service 22DID 2B08
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Rear left wheel speed XC60_RL_WHL_SPD_795

  • Service 22DID 2B08
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Rear right wheel speed XC60_RR_WHL_SPD

  • Service 22DID 2B09
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Rear right wheel speed XC60_RR_WHL_SPD_760

  • Service 22DID 2B09
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Rear right wheel speed XC60_RR_WHL_SPD_795

  • Service 22DID 2B09
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1997, 2008 to 2017.

Steering wheel angle sensor offset XC60_SAS_STEER_WHL_ANG

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val22.8533
Range
-1433 to 1433 °
Unit
°

In testing for 1997, 2008 to 2017.

Steering wheel angle sensor stored offset XC60_SAS_STEER_WHL_ANG_SENS

  • Service 22DID EE04
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1461
Range
-22.42 to 22.42 °
Unit
°

In testing for 1997, 2008 to 2017.

Steering wheel angle velocity XC60_STEER_WHL_ANG

  • Service 22DID 3301
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020
Unit
Raw value

In testing for 1997, 2008 to 2017.

Transmission

A/T converter XC60_T_CONV

  • Service 22DID 1E14
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 1997, 2008 to 2021.

AT, actual gear ratio XC60_ACT_GEAR_RAT

  • Service 22DID 1E16
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 1997, 2008 to 2021.

Clutch pump duty XC60_CLU_PMP_DUTY

  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Gear XC60_GEAR

  • Service 22DID DA85
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Gear ratio expected XC60_GEAR_RAT_EXPECTED

  • Service 22DID DA47
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1997, 2008 to 2021.

Gear ratio, actual XC60_GEAR_RAT_ACT

  • Service 22DID DA34
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61250000
Range
0 to 15.99
Unit
Number

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Gear ratio, actual XC60_GEAR_RAT_ACT_7E1

  • Service 22DID DA34
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 1997, 2008 to 2021.

Gear ratio, requested XC60_GEAR_RAT_REQ

  • Service 22DID DA47
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Gear, AT position XC60_GEAR_POS

  • Service 22DID DA40
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 1997, 2008 to 2021.

Torque converter lock XC60_TQ_CONV_LOCK

  • Service 22DID DA3C
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Transmission expected gear ratio XC60_EXPECTED_GEAR_RAT

  • Service 22DID 1E19
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission fluid temperature XC60_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID DA3B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Transmission fluid temperature XC60_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Transmission fluid temperature XC60_ATF_T_D016

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D900
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1000
Range
-32768000 to 32767000 °C
Unit
°C

In testing for 2018 to 2026.

Transmission fluid temperature, variant 2 XC60_ATF_T_VAR_2

  • Service 22DID D904
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Transmission fluid temperature, variant 2 XC60_ATF_T_VAR_2_7E1

  • Service 22DID DA3B
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Transmission fluid temperature, variant 3 XC60_ATF_T_VAR_3

  • Service 22DID D9A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 1997, 2008 to 2021.

Transmission gear XC60_GEAR_7E1

  • Service 22DID DD81
  • Module7E1
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Transmission gear selector p, 0 r, 1 n, 2 d, 3 XC60_GEAR_SELECTOR_P_0_R_1_N_2_D_3

  • Service 22DID 6310
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1997, 2008 to 2021.

Trips

All-wheel drive coupling distance XC60_HALDEX_DIST

  • Service 22DID DD01
  • Module795
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Distance since last service XC60_DIST_SINCE_SERVICE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Distance since last service XC60_DIST_SINCE_SERVICE_720

  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1997, 2008 to 2017.

Distance to empty XC60_DIST_EMPTY_MS_CAN

Pelican can show this parameter as the fuel range.

  • Service 22DID EEFD
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1997, 2008 to 2017.

Front left distance XC60_FL_DIST

  • Service 22DID B116
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Front left inner distance XC60_FL_INNER_DIST

  • Service 22DID B118
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Front right distance XC60_FR_DIST

  • Service 22DID B117
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Front right inner distance XC60_FR_INNER_DIST

  • Service 22DID B119
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2020, 2022, 2024 to 2026. Supported for 2018 to 2019, 2021.

Odometer XC60_MILEAGE_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2021.

Odometer XC60_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • ModuleD016 → 1EC64E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Odometer XC60_ODO_BCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_CEM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_CVM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module793
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_DDM_MS_CAN

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module740
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_DIM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module720
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_FSM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module764
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_PAM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module736
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_PBM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module756
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_PDM_MS_CAN

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module741
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_PPM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module794
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_PSCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module730
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_SAS

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module797
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_SRS

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module737
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Odometer XC60_ODO_TCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2021.

Odometer at last service XC60_ODO_LAST_SERVICE

  • Service 22DID D906
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Odometer at last service XC60_ODO_LAST_SERVICE_720

  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 1997, 2008 to 2017.

Primary, target range, m XC60_PRIMARY_TGT_RANGE_M

  • Service 22DID A223
  • Module764
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1997, 2008 to 2017.

Rear left distance XC60_RL_DIST

  • Service 22DID B112
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Rear left inner distance XC60_RL_INNER_DIST

  • Service 22DID B114
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Rear right distance XC60_RR_DIST

  • Service 22DID B113
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Rear right inner distance XC60_RR_INNER_DIST

  • Service 22DID B115
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 1997, 2008 to 2017.

Total distance XC60_DEM_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • ModuleD016 → 1EC70E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.